Vital Signs with Qualifying Elements
2.0.0 - ci-build International flag

Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions

: AverageBloodPressure-example - JSON Representation

Raw json | Download

{
  "resourceType" : "Observation",
  "id" : "AverageBloodPressure-example",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/fhir/us/vitals/StructureDefinition/average-blood-pressure"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation AverageBloodPressure-example</b></p><a name=\"AverageBloodPressure-example\"> </a><a name=\"hcAverageBloodPressure-example\"> </a><a name=\"AverageBloodPressure-example-en-US\"> </a><p><b>Measurement Protocol</b>: <span title=\"Codes:{http://hl7.org/fhir/us/vitals/CodeSystem/MeasurementProtocolTemporaryCodeSystem AOBP}\">Automated office blood pressure protocol</span></p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}\">Vital Signs</span></p><p><b>code</b>: <span title=\"Codes:{http://loinc.org 96607-7}\">Blood pressure panel mean systolic and mean diastolic</span></p><p><b>subject</b>: OldMan 1234</p><p><b>effective</b>: 2019-10-16 12:12:29-0900 --&gt; 2019-10-16 12:42:29-0900</p><p><b>issued</b>: 2019-10-16 12:12:29-1000</p><p><b>performer</b>: OldMan 1234</p><p><b>bodySite</b>: <span title=\"Codes:{http://snomed.info/sct 723961002}\">Structure of left brachial artery (body structure)</span></p><p><b>device</b>: <a href=\"Device-BPDevice2-example.html\">Device: extension = Blood pressure cuff, adult size (physical object); type = Automatic-inflation electronic sphygmomanometer, portable, arm/wrist (physical object)</a></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://loinc.org 96608-5}\">Systolic blood pressure mean</span></p><p><b>value</b>: 120 mm[Hg]<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemm[Hg] = 'mm[Hg]')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{http://loinc.org 96609-3}\">Diastolic blood pressure mean</span></p><p><b>value</b>: 80 mm[Hg]<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemm[Hg] = 'mm[Hg]')</span></p></blockquote></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/us/vitals/StructureDefinition/MeasurementProtocolExt",
      "valueCodeableConcept" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/us/vitals/CodeSystem/MeasurementProtocolTemporaryCodeSystem",
            "code" : "AOBP",
            "display" : "Automated office blood pressure protocol"
          }
        ]
      }
    }
  ],
  "status" : "final",
  "category" : [
    {
      "coding" : [
        {
          "system" : "http://terminology.hl7.org/CodeSystem/observation-category",
          "code" : "vital-signs",
          "display" : "Vital Signs"
        }
      ]
    }
  ],
  "code" : {
    "coding" : [
      {
        "system" : "http://loinc.org",
        "code" : "96607-7",
        "display" : "Blood pressure panel mean systolic and mean diastolic"
      }
    ]
  },
  "subject" : {
    "display" : "OldMan 1234"
  },
  "effectivePeriod" : {
    "start" : "2019-10-16T12:12:29-09:00",
    "end" : "2019-10-16T12:42:29-09:00"
  },
  "issued" : "2019-10-16T12:12:29-10:00",
  "performer" : [
    {
      "display" : "OldMan 1234"
    }
  ],
  "bodySite" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "code" : "723961002",
        "display" : "Structure of left brachial artery (body structure)"
      }
    ]
  },
  "device" : {
    🔗 "reference" : "Device/BPDevice2-example"
  },
  "component" : [
    {
      "code" : {
        "coding" : [
          {
            "system" : "http://loinc.org",
            "code" : "96608-5",
            "display" : "Systolic blood pressure mean"
          }
        ]
      },
      "valueQuantity" : {
        "value" : 120,
        "unit" : "mm[Hg]",
        "system" : "http://unitsofmeasure.org",
        "code" : "mm[Hg]"
      }
    },
    {
      "code" : {
        "coding" : [
          {
            "system" : "http://loinc.org",
            "code" : "96609-3",
            "display" : "Diastolic blood pressure mean"
          }
        ]
      },
      "valueQuantity" : {
        "value" : 80,
        "unit" : "mm[Hg]",
        "system" : "http://unitsofmeasure.org",
        "code" : "mm[Hg]"
      }
    }
  ]
}