Intersection of http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry and http://hl7.org/fhir/us/ecr/StructureDefinition/rr-relevant-reportable-condition-observation

This is the set of resources that conform to both US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry) and RR Relevant Reportable Condition Observation (http://hl7.org/fhir/us/ecr/StructureDefinition/rr-relevant-reportable-condition-observation).

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Observation C0..*left: US Core Pulse Oximetry Profile; right: RR Relevant Reportable Condition Observation
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
... meta Σ0..1MetaMetadata about the resource
ele-1: All FHIR elements must have a @value or children
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... language 0..1codeLanguage of the resource content
Binding: ?? (preferred): A human language.

Additional BindingsPurpose
??Max Binding

ele-1: All FHIR elements must have a @value or children
... text 0..1NarrativeText summary of the resource, for human interpretation
ele-1: All FHIR elements must have a @value or children
... contained 0..*ResourceContained, inline Resources
... extension 0..*Extensionleft: Additional content defined by implementations; right: Extension
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier Σ0..*IdentifierBusiness Identifier for observation
ele-1: All FHIR elements must have a @value or children
... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
ele-1: All FHIR elements must have a @value or children
... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
ele-1: All FHIR elements must have a @value or children
... status ?!SΣ1..1codeleft: (USCDI) registered | preliminary | final | amended +; right: registered | preliminary | final | amended +
Binding: ?? (required): Codes providing the status of an observation.


ele-1: All FHIR elements must have a @value or children
... category S1..*CodeableConceptleft: (USCDI) Classification of type of observation; right: Classification of type of observation
Binding: ?? (preferred): Codes for high level observation categories.


ele-1: All FHIR elements must have a @value or children
... code SΣ1..1CodeableConceptleft: (USCDI) Oxygen Saturation by Pulse Oximetry; right: Type of observation (code / type)
Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... coding SΣ2..*Codingleft: (USCDI) Code defined by a terminology system; right: Code defined by a terminology system
ele-1: All FHIR elements must have a @value or children
.... text Σ0..1stringPlain text representation of the concept
ele-1: All FHIR elements must have a @value or children
... subject SΣ1..1Reference(US Core Patient Profile)left: (USCDI) Who and/or what the observation is about; right: Who and/or what the observation is about
ele-1: All FHIR elements must have a @value or children
... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
ele-1: All FHIR elements must have a @value or children
... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is made
ele-1: All FHIR elements must have a @value or children
... effective[x] SΣC1..1left: (USCDI) Often just a dateTime for Vital Signs; right: Clinically relevant time/time-period for observation
ele-1: All FHIR elements must have a @value or children
vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
.... effectiveDateTimedateTime S
.... effectivePeriodPeriod
... issued Σ0..1instantDate/Time this version was made available
ele-1: All FHIR elements must have a @value or children
... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
ele-1: All FHIR elements must have a @value or children
... value[x] SΣ0..1left: (USCDI) Vital Signs Value; right: Actual result
Binding: ?? (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
.... valueQuantityQuantity S
.... valueCodeableConceptCodeableConcept
.... valueStringstring
.... valueBooleanboolean
.... valueIntegerinteger
.... valueRangeRange
.... valueRatioRatio
.... valueSampledDataSampledData
.... valueTimetime
.... valueDateTimedateTime
.... valuePeriodPeriod
... dataAbsentReason S0..1CodeableConceptleft: (USCDI) Why the result is missing; right: Use 'not-applicable' when eICR manually initiated or no reportable condition identified
Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ?? (extensible): Codes identifying interpretations of observations.


ele-1: All FHIR elements must have a @value or children
... note 0..*AnnotationComments about the observation
ele-1: All FHIR elements must have a @value or children
... bodySite 0..1CodeableConceptObserved body part
Binding: ?? (example): Codes describing anatomical locations. May include laterality.


ele-1: All FHIR elements must have a @value or children
... method 0..1CodeableConceptHow it was done
Binding: ?? (example): Methods for simple observations.


ele-1: All FHIR elements must have a @value or children
... specimen 0..1Reference(Specimen)Specimen used for this observation
ele-1: All FHIR elements must have a @value or children
... device 0..1Reference(Device | DeviceMetric)(Measurement) Device
ele-1: All FHIR elements must have a @value or children
... referenceRange C0..*BackboneElementProvides guide for interpretation
ele-1: All FHIR elements must have a @value or children
obs-3: Must have at least a low or a high or text
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... low 0..1??Low Range, if relevant
ele-1: All FHIR elements must have a @value or children
.... high 0..1??High Range, if relevant
ele-1: All FHIR elements must have a @value or children
.... type 0..1CodeableConceptReference range qualifier
Binding: ?? (preferred): Code for the meaning of a reference range.


ele-1: All FHIR elements must have a @value or children
.... appliesTo 0..*CodeableConceptReference range population
Binding: ?? (example): Codes identifying the population the reference range applies to.


ele-1: All FHIR elements must have a @value or children
.... age 0..1RangeApplicable age range, if relevant
ele-1: All FHIR elements must have a @value or children
.... text 0..1stringText based reference range in an observation
ele-1: All FHIR elements must have a @value or children
... hasMember SΣ1..*left: Used when reporting vital signs panel components; right: Related resource that belongs to the Observation group
ele-1: All FHIR elements must have a @value or children
... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
ele-1: All FHIR elements must have a @value or children
... component SΣC0..*BackboneElementleft: (USCDI) Used when reporting flow rates or oxygen concentration.; right: Component results
ele-1: All FHIR elements must have a @value or children
vs-3: If there is no a value a data absent reason must be present
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... code SΣ1..1CodeableConceptleft: (USCDI) Type of component observation (code / type); right: Type of component observation (code / type)
Binding: ?? (extensible): The vital sign codes from the base FHIR and US Core Vital Signs.


ele-1: All FHIR elements must have a @value or children
.... value[x] SΣ0..1left: (USCDI) Vital Sign Component Value; right: Actual component result
Binding: ?? (extensible): Common UCUM units for recording Vital Signs.


ele-1: All FHIR elements must have a @value or children
..... valueQuantityQuantity S
..... valueCodeableConceptCodeableConcept
..... valueStringstring
..... valueBooleanboolean
..... valueIntegerinteger
..... valueRangeRange
..... valueRatioRatio
..... valueSampledDataSampledData
..... valueTimetime
..... valueDateTimedateTime
..... valuePeriodPeriod
.... dataAbsentReason S0..1CodeableConceptleft: (USCDI) Why the component result is missing; right: Why the component result is missing
Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.


ele-1: All FHIR elements must have a @value or children
.... interpretation 0..*CodeableConceptHigh, low, normal, etc.
Binding: ?? (extensible): Codes identifying interpretations of observations.


ele-1: All FHIR elements must have a @value or children
.... referenceRange 0..*Provides guide for interpretation of component result
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format