HL7 Terminology (THO)
7.1.0 - Continuous Process Integration (ci build)
HL7 Terminology (THO), published by HL7 International - Vocabulary Work Group. This guide is not an authorized publication; it is the continuous build for version 7.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/UTG/ and changes regularly. See the Directory of published versions
| Official URL: http://terminology.hl7.org/ValueSet/v3-ActControlVariable | Version: 3.0.0 | ||||
| Responsible: Health Level Seven International | Computable Name: ActControlVariable | ||||
| Other Identifiers: OID:2.16.840.1.113883.1.11.16857 | |||||
Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html |
|||||
An observation form that determines parameters or attributes of an Act. Examples are the settings of a ventilator machine as parameters of a ventilator treatment act; the controls on dillution factors of a chemical analyzer as a parameter of a laboratory observation act; the settings of a physiologic measurement assembly (e.g., time skew) or the position of the body while measuring blood pressure.
Control variables are forms of observations because just as with clinical observations, the Observation.code determines the parameter and the Observation.value assigns the value. While control variables sometimes can be observed (by noting the control settings or an actually measured feedback loop) they are not primary observations, in the sense that a control variable without a primary act is of no use (e.g., it makes no sense to record a blood pressure position without recording a blood pressure, whereas it does make sense to record a systolic blood pressure without a diastolic blood pressure).
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
Language: en
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-ActCode version 📦10.0.0 where concept is-a _ActControlVariableThis value set excludes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-ActCode version 📦10.0.0| Code | Display | Definition |
| _ActControlVariable | ActControlVariable | An observation form that determines parameters or attributes of an Act. Examples are the settings of a ventilator machine as parameters of a ventilator treatment act; the controls on dillution factors of a chemical analyzer as a parameter of a laboratory observation act; the settings of a physiologic measurement assembly (e.g., time skew) or the position of the body while measuring blood pressure. Control variables are forms of observations because just as with clinical observations, the Observation.code determines the parameter and the Observation.value assigns the value. While control variables sometimes can be observed (by noting the control settings or an actually measured feedback loop) they are not primary observations, in the sense that a control variable without a primary act is of no use (e.g., it makes no sense to record a blood pressure position without recording a blood pressure, whereas it does make sense to record a systolic blood pressure without a diastolic blood pressure). |
Expansion performed internally based on codesystem ActCode v10.0.0 (CodeSystem)
This value set contains 4 concepts
| System | Code | Display (en) | Inactive | Definition | JSON | XML |
http://terminology.hl7.org/CodeSystem/v3-ActCode | AUTO | auto-repeat permission | Specifies whether or not automatic repeat testing is to be initiated on specimens. | |||
http://terminology.hl7.org/CodeSystem/v3-ActCode | ENDC | endogenous content | A baseline value for the measured test that is inherently contained in the diluent. In the calculation of the actual result for the measured test, this baseline value is normally considered. | |||
http://terminology.hl7.org/CodeSystem/v3-ActCode | REFLEX | reflex permission | Specifies whether or not further testing may be automatically or manually initiated on specimens. | |||
http://terminology.hl7.org/CodeSystem/v3-ActCode | _ECGControlVariable | ECGControlVariable | inactive |
Description of the above table(s).
History
| Date | Action | Custodian | Author | Comment |
| 2023-11-14 | revise | TSMG | Marc Duteau | Add standard copyright and contact to internal content; up-476 |
| 2022-10-18 | revise | TSMG | Marc Duteau | Fixing missing metadata; up-349 |
| 2020-05-06 | revise | Vocabulary WG | Ted Klein | Migrated to the UTG maintenance environment and publishing tooling. |
| 2014-03-26 | revise | 2014T1_2014-03-26_001283 (RIM release ID) | Vocabulary (Woody Beeler) (no record of original request) | Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26 |