HL7 Terminology (THO)
6.1.0 - Continuous Process Integration (ci build) International flag

HL7 Terminology (THO), published by HL7 International - Vocabulary Work Group. This guide is not an authorized publication; it is the continuous build for version 6.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/UTG/ and changes regularly. See the Directory of published versions

ValueSet: ObservationInterpretationNormalityAbnormal

Official URL: http://terminology.hl7.org/ValueSet/v3-ObservationInterpretationNormalityAbnormal Version: 3.0.0
Active as of 2014-03-26 Responsible: Health Level Seven International Computable Name: ObservationInterpretationNormalityAbnormal
Other Identifiers: OID:2.16.840.1.113883.1.11.10208

Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html

Interpretation of degree of abnormality (including critical or "alert" level). Concepts in this category are mutually exclusive, i.e., at most one is allowed.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

Generated Narrative: ValueSet v3-ObservationInterpretationNormalityAbnormal

Language: en

 

Expansion

Generated Narrative: ValueSet

Language: en

Expansion based on codesystem ObservationInterpretation v3.0.0 (CodeSystem)

This value set contains 10 concepts

CodeSystemDisplayInactiveDefinitionstatus
  Ahttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationAbnormal

The result or observation value is outside the reference range or expected norm (as defined for the respective test procedure).

[Note: Typically applies to non-numeric results.]

  AAhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationCritical abnormal

The result or observation value is outside a reference range or expected norm at a level at which immediate action should be considered for patient safety (as defined for the respective test procedure).

[Note: Typically applies to non-numeric results. Analogous to critical/panic limits for numeric results.]

  HHhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationCritical high

The result for a quantitative observation is above a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).

Synonym: Above upper panic limits.

  LLhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationCritical low

The result for a quantitative observation is below a reference level at which immediate action should be considered for patient safety (as defined for the respective test procedure).

Synonym: Below lower panic limits.

  Hhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationHigh

The result for a quantitative observation is above the upper limit of the reference range (as defined for the respective test procedure).

Synonym: Above high normal

  H>http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationSignificantly highinactive

A test result that is significantly higher than the reference (normal) or therapeutic interval, but has not reached the critically high value and might need special attention, as defined by the laboratory or the clinician.

[Note: This level is situated between 'H' and 'HH'.]

Deprecation Comment: The code 'H>' is being deprecated in order to align with the use of the code 'HU' for "Very high" in V2 Table 0078 "Interpretation Codes".

[Note: The use of code 'H>' is non-preferred, as this code is deprecated and on track to be retired; use code 'HU' instead.

deprecated
  HUhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationSignificantly high

A test result that is significantly higher than the reference (normal) or therapeutic interval, but has not reached the critically high value and might need special attention, as defined by the laboratory or the clinician.

  Lhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationLow

The result for a quantitative observation is below the lower limit of the reference range (as defined for the respective test procedure).

Synonym: Below low normal

  L<http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationSignificantly lowinactive

A test result that is significantly lower than the reference (normal) or therapeutic interval, but has not reached the critically low value and might need special attention, as defined by the laboratory or the clinician.

[Note: This level is situated between 'L' and 'LL'.]

Deprecation Comment: The code 'L<' is being deprecated in order to align with the use of the code 'LU' for "Very low" in V2 Table 0078 "Interpretation Codes".

[Note: The use of code 'L<' is non-preferred, as this code is deprecated and on track to be retired; use code 'LU' instead.

deprecated
  LUhttp://terminology.hl7.org/CodeSystem/v3-ObservationInterpretationSignificantly low

A test result that is significantly lower than the reference (normal) or therapeutic interval, but has not reached the critically low value and might need special attention, as defined by the laboratory or the clinician.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code

History

DateActionCustodianAuthorComment
2023-11-14reviseTSMGMarc DuteauAdd standard copyright and contact to internal content; up-476
2022-10-18reviseTSMGMarc DuteauFixing missing metadata; up-349
2020-05-06reviseVocabulary WGTed KleinMigrated to the UTG maintenance environment and publishing tooling.
2014-03-26revise2014T1_2014-03-26_001283 (RIM release ID)Vocabulary (Woody Beeler) (no record of original request)Lock all vaue sets untouched since 2014-03-26 to trackingId 2014T1_2014_03_26