HL7 Terminology (THO)
6.1.0 - Continuous Process Integration (ci build)
HL7 Terminology (THO), published by HL7 International - Vocabulary Work Group. This guide is not an authorized publication; it is the continuous build for version 6.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/UTG/ and changes regularly. See the Directory of published versions
Official URL: http://terminology.hl7.org/ValueSet/v3-ActRelationshipStartsAfterOrConcurrentWithStartOf | Version: 3.0.0 | |||
Active as of 2014-08-07 | Responsible: Health Level Seven International | Computable Name: ActRelationshipStartsAfterOrConcurrentWithStartOf | ||
Other Identifiers: OID:2.16.840.1.113883.1.11.20515 | ||||
Copyright/Legal: This material derives from the HL7 Terminology THO. THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html |
Pro-forma value set for each head code in the ActRelationshipType code system; all codes present and future below the head code.
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
Generated Narrative: ValueSet v3-ActRelationshipStartsAfterOrConcurrentWithStartOf
Language: en
http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType
where concept is-a SASORSCW
Generated Narrative: ValueSet
Language: en
Expansion based on codesystem ActRelationshipType v4.0.0 (CodeSystem)
This value set contains 13 concepts
Code | System | Display | Definition |
SASORSCW | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts after or concurrent with start of | A relationship in which the source act's effective time starts after or concurrent with the start of the target act's effective time. Usage Note: Inverse code is SBSORSCW |
SAS | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts after start of | The source Act starts after the start of the target Act (i.e. if we say "ActOne SAS ActTwo", it means that ActOne starts after the start of ActTwo, therefore ActOne is the source and ActTwo is the target). UsageNote: Inverse code is SBS |
SASEAE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts after start of, ends after end of | The source Act starts after start of the target Act and ends after end of the target Act. UsageNote: Inverse code is SBSEBE |
SBEEAE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | contains end of | The source Act contains the end of the target Act. UsageNote: Inverse code is EDU |
SASSBEEAS | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | start after start of, contains end of | The source Act start after the start of the target Act, and contains the end of the target Act. UsageNote: Inverse code is SBSEASEBE |
SBSEAE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | contains time of | The source Act contains the time of the target Act. UsageNote: Inverse code is DURING |
SCWSEAE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts with, ends after end of | The source Act starts with the target Act, and ends after the end of the target Act. |
SAE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts after end of | A relationship in which the source act starts after the target act ends. UsageNote: Inverse code is EBS |
DURING | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | occurs during | A relationship in which the source act's effective time is wholly within the target act's effective time (including end points, as defined in the act's effective times) UsageNote: Inverse code is SBSEAE |
SASECWE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts after start of, ends with | The source Act starts after start of the target Act, and ends with the target Act. UsageNote: Inverse code is SBSECWE |
SCW | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts concurrent with | A relationship in which the source act's effective time starts with the start of the target act's effective time. UsageNote: This code is reflexive. Therefore its inverse code is itself. |
CONCURRENT | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | concurrent with | A relationship in which the source act's effective time is the same as the target act's effective time. UsageNote: This code is reflexive. Therefore its inverse code is itself. |
SCWSEBE | http://terminology.hl7.org/CodeSystem/v3-ActRelationshipType | starts with. ends before end of | The source Act starts with.the target Act and ends before the end of the target Act. UsageNote: Inverse code is SCWSEAE |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |
History
Date | Action | Custodian | Author | Comment |
2023-11-14 | revise | TSMG | Marc Duteau | Add standard copyright and contact to internal content; up-476 |
2022-10-18 | revise | TSMG | Marc Duteau | Fixing missing metadata; up-349 |
2020-05-06 | revise | Vocabulary WG | Ted Klein | Migrated to the UTG maintenance environment and publishing tooling. |
2014-08-07 | revise | 2014T2_2014-08-07_001289 (RIM release ID) | CQI (Marc Hadley) (no record of original request) | Pro-forma value set creation. |