HL7 Terminology (THO)
6.0.2 - Continuous Process Integration (ci build) International flag

HL7 Terminology (THO), published by HL7 International - Vocabulary Work Group. This guide is not an authorized publication; it is the continuous build for version 6.0.2 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/UTG/ and changes regularly. See the Directory of published versions

CodeSystem: HL7ConformanceInclusion

Official URL: http://terminology.hl7.org/CodeSystem/v3-HL7ConformanceInclusion Version: 2.0.1
Retired as of 2019-03-20 Responsible: Health Level 7 Computable Name: HL7ConformanceInclusion
Other Identifiers: OID:2.16.840.1.113883.5.55

These concepts represent theconformance requirments defined for including or valuing an element of an HL7 message. The concepts apply equally to conformance profiles defined for Version 2.x messgaes as defined by the Conformance SIG, and to the conformance columns for Version 3 messages as specified in the HMD.

Deprecation Comment: Deprecated as per 11/2008 Harmonization cleanup; internal and obsolete HL7 usage, no longer used.

This Code system is referenced in the content logical definition of the following value sets:

  • This CodeSystem is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Generated Narrative: CodeSystem v3-HL7ConformanceInclusion

Language: en

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
Specializes Specializes Coding The child code is a more narrow version of the concept represented by the parent code. I.e. Every child concept is also a valid parent concept. Used to allow determination of subsumption. Must be transitive, irreflexive, antisymmetric.
Generalizes Generalizes Coding Inverse of Specializes. Only included as a derived relationship.
internalId internalId http://terminology.hl7.org/CodeSystem/utg-concept-properties#v3-internal-id code The internal identifier for the concept in the HL7 Access database repository.
Not Selectable notSelectable http://hl7.org/fhir/concept-properties#notSelectable boolean Indicates that the code is abstract - only intended to be used as a selector for other concepts
Status status http://hl7.org/fhir/concept-properties#status code Designation of a concept's state. Normally is not populated unless the state is retired.
Synonym synonymCode http://hl7.org/fhir/concept-properties#synonym code An additional concept code that was also attributed to a concept

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v3-HL7ConformanceInclusion defines the following codes in a Is-A hierarchy:

LvlCodeDisplayDefinitioninternalIdNot SelectableStatusSynonym
1 _InclusionNotMandatory InclusionNotMandatory The message element is not mandatory, but its appearance may be constrained by one of the non-mandatory concepts. 21081 true active
2   NP Not permitted This message element may not appear when the message is communicated. 10014 active
2   NR Not required The message element may be populated or used by one system sponsor (or profile), but not by another. Each system sponsor or profile is required to state the ability to accept or send the message element as part of a conformance claim. 10015 active
3     RE Required may be empty Pursuant to a profile or vendor conformance claim, the message element must appear every time the message is communicated, but the value may be communicated as null. 10016 active
3     X Excluded Pursuant to a profile or vendor conformance claim, this message element may not appear when the message is communicated. 10017 active
2   RQ Required The message element must appear every time the message is communicated, but the value may be communicated as null. 10013 active
1 M Mandatory The message element must appear every time the message is communicated and its value must not be null. This condition is subject to the rules of multiplicity and conditionality. If a non-null default value is defined for the element, a null value may be communicated. 10011 active R
1 R Mandatory The message element must appear every time the message is communicated and its value must not be null. This condition is subject to the rules of multiplicity and conditionality. If a non-null default value is defined for the element, a null value may be communicated. 10011 active M

History

DateActionAuthorCustodianComment
2022-07-22reviseJessica BotaTSMGAdd default value of TRUE for code systems missing caseSensitive element unless otherwise specified; UP-322
2021-01-14deprecateWoody BeelerMnMdeprecationEffectiveVersion=661-20081229 This Code System was deprecated (retired) as of the Vocabulary Model version shown.
2020-05-06reviseTed KleinVocabulary WGMigrated to the UTG maintenance environment and publishing tooling.