  "resourceType" : "Observation",
  "id" : "IDCOExample2",
  "meta" : {
    "profile" : ["http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/IdcoObservation"]
  },
  "language" : "en",
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\" xml:lang=\"en\" lang=\"en\"><p class=\"res-header-id\"><b>Generated Narrative: Observation IDCOExample2</b></p><a name=\"IDCOExample2\"> </a><a name=\"hcIDCOExample2\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Language: en</p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-IdcoObservation.html\">Implantable Device Cardiac Observation</a></p></div><p><b>status</b>: Final</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 720908}\">Implantable Device Cardiac Observation - TEMPORARY CODE.</span></p><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721216}\">Battery Date Time of Measurements</span></p><p><b>value</b>: 2019-10-16 12:12:29-0900</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721280}\">Battery Status</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754113}\">Beginning of Service</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721344}\">Battery Voltage</span></p><p><b>value</b>: 6.2 V<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeV = 'V')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721408}\">Battery Impedance</span></p><p><b>value</b>: 2450 Ohm<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeOhm = 'Ohm')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721472}\">Battery Remaining Longevity</span></p><p><b>value</b>: 38 mo<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemo = 'mo')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721536}\">Battery Remaining Percentage</span></p><p><b>value</b>: 75 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  code% = '%')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721600}\">Battery RRT Trigger</span></p><p><b>value</b>: Battery capacity &lt; limit for 3 months</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721601}\">Battery Remaining Longevity Timeframe</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754115}\">RRT</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721602}\">Battery Remaining Percentage Timeframe</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754115}\">RRT</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721603}\">Battery RRT Reached Date Time</span></p><p><b>value</b>: 2025-03-21 12:12:29-0900</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721664}\">Capacitor Last Charge Date Time</span></p><p><b>value</b>: 2018-03-21 12:12:29-0900</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721728}\">Capacitor Charge Time</span></p><p><b>value</b>: 9.4 s<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codes = 's')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721792}\">Capacitor Charge Energy</span></p><p><b>value</b>: 30 J<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeJ = 'J')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721856}\">Capacitor Charge Type</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754177}\">Shock</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721921}\">Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_START</span></p><p><b>value</b>: 2019-03-21 12:12:29-0900</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721922}\">Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_END</span></p><p><b>value</b>: 2020-03-21 12:12:29-0900</p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 721984}\">Lead Channel Status MDC_IDC_MSMT_LEADCHNL_RA_LEAD_CHANNEL_STATUS</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754241}\">Check Lead</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722049}\">Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MAX</span></p><p><b>value</b>: 2.6 mV<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemV = 'mV')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722050}\">Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MIN</span></p><p><b>value</b>: 2.2 mV<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemV = 'mV')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722051}\">Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MEAN</span></p><p><b>value</b>: 2.5 mV<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codemV = 'mV')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722112}\">Lead Channel Sensing Polarity MDC_IDC_MSMT_LEADCHNL_RA_SENSING_POLARITY</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754305}\">Unipolar</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722176}\">Lead Channel Pacing Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_AMPLITUDE</span></p><p><b>value</b>: 0.7 V<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeV = 'V')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722240}\">Lead Channel Pacing Threshold Pulse Width MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_PULSEWIDTH</span></p><p><b>value</b>: 0.5 ms<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codems = 'ms')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722304}\">Lead Channel Pacing Threshold Measurement Method MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_MEASUREMENT_METHOD</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754371}\">Device Automatic</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722368}\">Lead Channel Pacing Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_POLARITY</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754306}\">Bipolar</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722432}\">Lead Channel Impedance Value MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_VALUE</span></p><p><b>value</b>: 530 Ohm<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeOhm = 'Ohm')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 722496}\">Lead Channel Impedance Polarity MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_POLARITY</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754306}\">Bipolar</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731520}\">Tachy Therapy Setting Ventricular Status</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754817}\">On</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731648}\">Zone Setting Type Category</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754945}\">VF</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731712}\">Zone Setting Vendor Type Category</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 772161}\">A Medtronic zone subclassification of ventricular fibrillation.</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731776}\">Zone Setting Status</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 755009}\">Active</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731840}\">Zone Setting Detection Interval</span></p><p><b>value</b>: 300 ms<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codems = 'ms')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732097}\">Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 755073}\">Burst</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732097}\">Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 755073}\">Burst</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732161}\">Zone Setting Number of ATP Sequences MDC_IDC_SET_ZONE_NUM_ATP_SEQS_1</span></p><p><b>value</b>: 1</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732225}\">The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_1</span></p><p><b>value</b>: 0.6 J<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeJ = 'J')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732289}\">Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_1</span></p><p><b>value</b>: 1</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732226}\">The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_2</span></p><p><b>value</b>: 0.6 J<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeJ = 'J')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732290}\">Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_2</span></p><p><b>value</b>: 1</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732227}\">The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_3</span></p><p><b>value</b>: 41 J<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codeJ = 'J')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 1</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 732291}\">Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_3</span></p><p><b>value</b>: 1</p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 2</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731648}\">Zone Setting Type Category</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 754946}\">VT</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 2</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731712}\">Zone Setting Vendor Type Category</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 772161}\">A Medtronic zone subclassification of ventricular fibrillation.</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 2</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731776}\">Zone Setting Status</span></p><p><b>value</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 755011}\">Monitor</span></p></blockquote><blockquote><p><b>component</b></p><p><b>Instance of repeatable element</b>: 2</p><p><b>code</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 731840}\">Zone Setting Detection Interval</span></p><p><b>value</b>: 375 ms<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codems = 'ms')</span></p></blockquote></div>"
  },
  "status" : "final",
  "code" : {
    "coding" : [{
      "system" : "urn:iso:std:iso:11073:10101",
      "code" : "720908",
      "display" : "Implantable Device Cardiac Observation - TEMPORARY CODE."
    }]
  },
  "component" : [{
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721216",
        "display" : "Battery Date Time of Measurements"
      }]
    },
    "valueDateTime" : "2019-10-16T12:12:29-09:00"
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721280",
        "display" : "Battery Status"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754113",
        "display" : "Beginning of Service"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721344",
        "display" : "Battery Voltage"
      }]
    },
    "valueQuantity" : {
      "value" : 6.2,
      "unit" : "V",
      "system" : "http://unitsofmeasure.org",
      "code" : "V"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721408",
        "display" : "Battery Impedance"
      }]
    },
    "valueQuantity" : {
      "value" : 2450,
      "unit" : "Ohm",
      "system" : "http://unitsofmeasure.org",
      "code" : "Ohm"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721472",
        "display" : "Battery Remaining Longevity"
      }]
    },
    "valueQuantity" : {
      "value" : 38,
      "unit" : "mo",
      "system" : "http://unitsofmeasure.org",
      "code" : "mo"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721536",
        "display" : "Battery Remaining Percentage"
      }]
    },
    "valueQuantity" : {
      "value" : 75,
      "unit" : "%",
      "system" : "http://unitsofmeasure.org",
      "code" : "%"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721600",
        "display" : "Battery RRT Trigger"
      }]
    },
    "valueString" : "Battery capacity < limit for 3 months"
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721601",
        "display" : "Battery Remaining Longevity Timeframe"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754115",
        "display" : "RRT"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721602",
        "display" : "Battery Remaining Percentage Timeframe"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754115",
        "display" : "RRT"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721603",
        "display" : "Battery RRT Reached Date Time"
      }]
    },
    "valueDateTime" : "2025-03-21T12:12:29-09:00"
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721664",
        "display" : "Capacitor Last Charge Date Time"
      }]
    },
    "valueDateTime" : "2018-03-21T12:12:29-09:00"
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721728",
        "display" : "Capacitor Charge Time"
      }]
    },
    "valueQuantity" : {
      "value" : 9.4,
      "unit" : "s",
      "system" : "http://unitsofmeasure.org",
      "code" : "s"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721792",
        "display" : "Capacitor Charge Energy"
      }]
    },
    "valueQuantity" : {
      "value" : 30,
      "unit" : "J",
      "system" : "http://unitsofmeasure.org",
      "code" : "J"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721856",
        "display" : "Capacitor Charge Type"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754177",
        "display" : "Shock"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721921",
        "display" : "Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_START"
      }]
    },
    "valueDateTime" : "2019-03-21T12:12:29-09:00"
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721922",
        "display" : "Lead Channel Measurements Date and Time MDC_IDC_MSMT_LEADCHNL_RA_DTM_END"
      }]
    },
    "valueDateTime" : "2020-03-21T12:12:29-09:00"
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "721984",
        "display" : "Lead Channel Status MDC_IDC_MSMT_LEADCHNL_RA_LEAD_CHANNEL_STATUS"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754241",
        "display" : "Check Lead"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722049",
        "display" : "Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MAX"
      }]
    },
    "valueQuantity" : {
      "value" : 2.6,
      "unit" : "mV",
      "system" : "http://unitsofmeasure.org",
      "code" : "mV"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722050",
        "display" : "Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MIN"
      }]
    },
    "valueQuantity" : {
      "value" : 2.2,
      "unit" : "mV",
      "system" : "http://unitsofmeasure.org",
      "code" : "mV"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722051",
        "display" : "Lead Channel Sensing Intrinsic Amplitude MDC_IDC_MSMT_LEADCHNL_RA_SENSING_INTR_AMPL_MEAN"
      }]
    },
    "valueQuantity" : {
      "value" : 2.5,
      "unit" : "mV",
      "system" : "http://unitsofmeasure.org",
      "code" : "mV"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722112",
        "display" : "Lead Channel Sensing Polarity MDC_IDC_MSMT_LEADCHNL_RA_SENSING_POLARITY"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754305",
        "display" : "Unipolar"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722176",
        "display" : "Lead Channel Pacing Threshold Amplitude MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_AMPLITUDE"
      }]
    },
    "valueQuantity" : {
      "value" : 0.7,
      "unit" : "V",
      "system" : "http://unitsofmeasure.org",
      "code" : "V"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722240",
        "display" : "Lead Channel Pacing Threshold Pulse Width MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_PULSEWIDTH"
      }]
    },
    "valueQuantity" : {
      "value" : 0.5,
      "unit" : "ms",
      "system" : "http://unitsofmeasure.org",
      "code" : "ms"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722304",
        "display" : "Lead Channel Pacing Threshold Measurement Method MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_MEASUREMENT_METHOD"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754371",
        "display" : "Device Automatic"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722368",
        "display" : "Lead Channel Pacing Threshold Polarity MDC_IDC_MSMT_LEADCHNL_RA_PACING_THRESHOLD_POLARITY"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754306",
        "display" : "Bipolar"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722432",
        "display" : "Lead Channel Impedance Value MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_VALUE"
      }]
    },
    "valueQuantity" : {
      "value" : 530,
      "unit" : "Ohm",
      "system" : "http://unitsofmeasure.org",
      "code" : "Ohm"
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "722496",
        "display" : "Lead Channel Impedance Polarity MDC_IDC_MSMT_LEADCHNL_RA_IMPEDANCE_POLARITY"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754306",
        "display" : "Bipolar"
      }]
    }
  },
  {
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731520",
        "display" : "Tachy Therapy Setting Ventricular Status"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754817",
        "display" : "On"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731648",
        "display" : "Zone Setting Type Category"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754945",
        "display" : "VF"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731712",
        "display" : "Zone Setting Vendor Type Category"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "772161",
        "display" : "A Medtronic zone subclassification of ventricular fibrillation."
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731776",
        "display" : "Zone Setting Status"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "755009",
        "display" : "Active"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731840",
        "display" : "Zone Setting Detection Interval"
      }]
    },
    "valueQuantity" : {
      "value" : 300,
      "unit" : "ms",
      "system" : "http://unitsofmeasure.org",
      "code" : "ms"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732097",
        "display" : "Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "755073",
        "display" : "Burst"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732097",
        "display" : "Zone Setting ATP Type MDC_IDC_SET_ZONE_TYPE_ATP_1"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "755073",
        "display" : "Burst"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732161",
        "display" : "Zone Setting Number of ATP Sequences MDC_IDC_SET_ZONE_NUM_ATP_SEQS_1"
      }]
    },
    "valueQuantity" : {
      "value" : 1
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732225",
        "display" : "The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_1"
      }]
    },
    "valueQuantity" : {
      "value" : 0.6,
      "unit" : "J",
      "system" : "http://unitsofmeasure.org",
      "code" : "J"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732289",
        "display" : "Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_1"
      }]
    },
    "valueQuantity" : {
      "value" : 1
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732226",
        "display" : "The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_2"
      }]
    },
    "valueQuantity" : {
      "value" : 0.6,
      "unit" : "J",
      "system" : "http://unitsofmeasure.org",
      "code" : "J"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732290",
        "display" : "Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_2"
      }]
    },
    "valueQuantity" : {
      "value" : 1
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732227",
        "display" : "The shock energy delivered at a particular sequence of a zone therapy. MDC_IDC_SET_ZONE_SHOCK_ENERGY_3"
      }]
    },
    "valueQuantity" : {
      "value" : 41,
      "unit" : "J",
      "system" : "http://unitsofmeasure.org",
      "code" : "J"
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 1
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "732291",
        "display" : "Zone Setting Number of Shocks MDC_IDC_SET_ZONE_NUM_SHOCKS_3"
      }]
    },
    "valueQuantity" : {
      "value" : 1
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 2
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731648",
        "display" : "Zone Setting Type Category"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "754946",
        "display" : "VT"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 2
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731712",
        "display" : "Zone Setting Vendor Type Category"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "772161",
        "display" : "A Medtronic zone subclassification of ventricular fibrillation."
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 2
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731776",
        "display" : "Zone Setting Status"
      }]
    },
    "valueCodeableConcept" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "755011",
        "display" : "Monitor"
      }]
    }
  },
  {
    "extension" : [{
      "url" : "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/instance-idco",
      "valueInteger" : 2
    }],
    "code" : {
      "coding" : [{
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "731840",
        "display" : "Zone Setting Detection Interval"
      }]
    },
    "valueQuantity" : {
      "value" : 375,
      "unit" : "ms",
      "system" : "http://unitsofmeasure.org",
      "code" : "ms"
    }
  }]
}