Intersection of http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CardXCIED and http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CardXCIED

This is the CodeSystem that contains codes in both CardX CIED FHIR IG Code System (http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CardXCIED) and CardX CIED FHIR IG Code System (http://hl7.org/fhir/uv/cardx-cied/CodeSystem/CardXCIED).

Structure

Generated Narrative: CodeSystem c511af70-717e-4fc1-8ec0-8b6e18643c87-3

This code system http://hl7.org/fhir/comparison/CodeSystem/c511af70-717e-4fc1-8ec0-8b6e18643c87-3 defines codes, but no codes are represented here

CodeDisplayDefinition
connectivity-status Connectivity statusThe overall system connectivity status as calculated by the CIED manufacturer.
connectivity-modifier Connectivity modifierAdditional modifiers to connectivity status as calculated by the CIED manufacturer.
setup-not-completed Setup not completedDevice/monitor setup has not been completed. E.g. pending initial setup or there is no device/monitor association.
not-applicable N/AConnectivity states are not applicable for this device. E.g. device is not compatible with remote monitoring or requires patient initiated interrogations.
connected ConnectedCommunication has been successful within the expected time period.
disconnected DisconnectedCommunication has not occurred within the expected time period.
suspended SuspendedPatient has been temporarily removed from the disconnected state. This is not intended to be an actionable status.
inactive InactivePatient has been permanently removed from the disconnected status.
unenrolled UnenrolledPatient has been unenrolled from remote monitoring or remote monitoring has been discontinued.
transferred TransferredThe patient has been transferred to another remote monitoring clinic.
last-cied-connectivity-time Last CIED to monitor communicationThe timestamp of the most recent communication between the CIED and monitor.
last-monitor-connectivity-time Last monitor to remote monitoring software communicationThe timestamp of the most recent communication from the monitor to the remote monitoring platform.
next-cied-connectivity-date Next CIED to monitor communicationThe timestamp of the next expected communication between the CIED and monitor.
next-monitor-connectivity-date Next monitor to remote monitoring software communicationThe timestamp of the next expected communication from the monitor to the remote monitoring platform.
last-interrogation-date Last remote device interrogation dateThe date of the most recent remote device interrogation with a personal monitor.
next-interrogation-date Next scheduled remote device interrogation dateThe date of the next scheduled remote device interrogation.
next-secondary-interrogation-date Next scheduled remote device interrogation date, secondary clinicThe date of the next scheduled remote device interrogation by the secondary clinic for patients who are dual-managed.
observation-cied-connectivity CIED connectivityFHIR observation constrained to the CardX CIED connectivity profile.
bedside-device Bedside MonitorStandalone device, not intended to provide monitoring while on the go.
mobile-monitor Mobile AppApp based monitor.
portable-device Portable DeviceStandalone device, with battery capacity to provide monitoring while on the go.
connection-interval Connection intervalThe time interval in days between expected CIED and remote monitoring software communication.
expected-time-period Expected time periodThe time period in days in which successful communication must take place for the connectivity status to remain connected.
status-reason Status reasonText describing reasons why the patient may be listed at a given status and/or modifier.
status-guidance Status guidanceText describing steps to get the patient to a connected status.
idco-pid Identifier used in IDCO PID HL7 SegmentIDCO specifies a combination of model and serial number as model:model-number/serial:serial-number