ValueSet Comparison between http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode vs http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1267.36

Messages

ErrorValueSet.urlValues for url differ: 'http://hl7.org/cda/stds/core/ValueSet/CDAEntityCode' vs 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1267.36'
InformationValueSet.nameValues for name differ: 'CDAEntityCode' vs 'DeviceTypes'
InformationValueSet.titleValues for title differ: 'CDAEntityCode' vs 'Device Types'
InformationValueSet.statusValues for status differ: 'draft' vs 'active'
InformationValueSet.publisherValues for publisher differ: 'Health Level 7' vs 'HL7 US Realm Program Management Steward'
InformationValueSet.jurisdictionAdded the item 'urn:iso:std:iso:3166#US'

Metadata

NameValueComments
.compose.inactive
    .compose.lockedDate
      .copyright
        .descriptionA value representing the specific kind of Entity the instance represents.This value set aligns with the HL7 FHIR DeviceType value set used in US Core (https://hl7.org/fhir/R4/valueset-device-kind.html). C-CDA cannot reuse the US Core value set because it was removed in FHIR R5, which the C-CDA StructureDefinition publication depends on.
        • Values Differ
        .experimentalfalse
        • Removed the item 'false'
        .immutable
          .jurisdiction
            ..jurisdiction[0]urn:iso:std:iso:3166#US
            • Added the item 'urn:iso:std:iso:3166#US'
            .nameCDAEntityCodeDeviceTypes
            • Values Differ
            .publisherHealth Level 7HL7 US Realm Program Management Steward
            • Values Differ
            .purpose(Clinical Focus: This value set contains concepts that represent medical devices used in patient care, including implantable, therapeutic, monitoring, diagnostic, assistive, and other clinical devices, drawn from the SNOMED CT Device hierarchy (descendants of 49062001)),(Data Element Scope: The value set is intended for use in data elements that capture the type or kind of a medical device associated with a patient. It is aligned with the HL7 FHIR Device type (“device-kind”) value set.),(Inclusion Criteria: SNOMED CT concepts that are descendants of 49062001 (Device), representing physical medical devices used in the provision, monitoring, or support of patient care.),(Exclusion Criteria: Concepts that are not descendants of 49062001 (Device). Non-device concepts (e.g., medications, procedures, body structures, findings). Deprecated or inactive SNOMED CT concepts.)
            • Added the item '(Clinical Focus: This value set contains concepts that represent medical devices used in patient care, including implantable, therapeutic, monitoring, diagnostic, assistive, and other clinical devices, drawn from the SNOMED CT Device hierarchy (descendants of 49062001)),(Data Element Scope: The value set is intended for use in data elements that capture the type or kind of a medical device associated with a patient. It is aligned with the HL7 FHIR Device type (“device-kind”) value set.),(Inclusion Criteria: SNOMED CT concepts that are descendants of 49062001 (Device), representing physical medical devices used in the provision, monitoring, or support of patient care.),(Exclusion Criteria: Concepts that are not descendants of 49062001 (Device). Non-device concepts (e.g., medications, procedures, body structures, findings). Deprecated or inactive SNOMED CT concepts.)'
            .statusdraftactive
            • Values Differ
            .titleCDAEntityCodeDevice Types
            • Values Differ
            .urlhttp://hl7.org/cda/stds/core/ValueSet/CDAEntityCodehttp://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1267.36
            • Values Differ

            Definition

            ItemPropertyValueComments
            .include
            • Removed Include
            .includehttp://terminology.hl7.org/CodeSystem/v3-EntityCode
            • Removed Include
            .includehttp://snomed.info/sctVersion: http://snomed.info/sct/731000124108/version/20250901
            • Added Include

            Expansion

            Unable to generate expansion - see errors