Union of http://hl7.org/cda/us/ccda/StructureDefinition/MedicalEquipmentOrganizer and http://hl7.org/cda/us/ccda/StructureDefinition/MedicalEquipmentOrganizer

This is the set of resources that conform to either of the profiles Medical Equipment Organizer (http://hl7.org/cda/us/ccda/StructureDefinition/MedicalEquipmentOrganizer) and Medical Equipment Organizer (http://hl7.org/cda/us/ccda/StructureDefinition/MedicalEquipmentOrganizer). E.g. what you have to deal with if you get resources conforming to one of them

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Organizer C1..1Base for all types and resources
should-sdtctext-ref-value: SHOULD contain text/reference/@value
1098-32380: Either Non-Medicinal Supply Activity (templateId:2.16.840.1.113883.10.20.22.4.50:2014-06-09) **OR** Procedure Activity Procedure (templateId:2.16.840.1.113883.10.20.22.4.14:2014-06-09) **SHALL** be present (CONF:1098-32380).
... nullFlavor 0..1??Binding: ?? (required)
... realmCode 0..*CS
... typeId 0..1II
.... nullFlavor 0..1??Binding: ?? (required)
.... assigningAuthorityName 0..1??
.... displayable 0..1??
.... root 1..1??, ??, ??
.... extension 1..1??
... classCode 1..1??Binding: ?? (required)
... moodCode 1..1??Binding: ?? (required)
... code 0..1CDThis code can represent a category of devices. The code is strictly optional, and is not currently limited to any value set or code system. Implementers may use it if they wish to provide optional coded information about this grouping of medical equipment.
Binding: ?? (example)
... sdtcText 0..1EDSHOULD reference the portion of section narrative text corresponding to this entry
.... nullFlavor 0..1??Binding: ?? (required)
.... compression 0..1??Binding: ?? (required)
.... integrityCheck 0..1??
.... integrityCheckAlgorithm 0..1??Binding: ?? (required)
.... language 0..1??
.... mediaType 0..1??Binding: ?? (example)
.... representation 0..1??Binding: ?? (required)
.... xmlText 0..1??Allows for mixed text content. If @representation='B64', this SHALL be a base64binary string.
.... reference C0..1TELvalue-starts-octothorpe: If reference/@value is present, it SHALL begin with a '#' and SHALL point to its corresponding narrative
.... thumbnail 0..1ED
... statusCode 1..1CSThe organizer is a collection of statuses for contained entries. The organizer remains active until all contained entries are done.
Binding: ?? (required)
.... code 1..1??Binding: ?? (required)
.... sdtcValueSet 0..1??
.... sdtcValueSetVersion 0..1??
... effectiveTime 1..1IVL_TSThe effectiveTime can be used to show the time period over which the patient will be using the set of equipment. The organizer would probably not be used with devices applied in or on the patient.
.... nullFlavor 0..1??Binding: ?? (required)
.... value 0..1??
.... operator 0..1??Binding: ?? (required)
.... low 1..1IVXB_TS
.... center 0..1TS
.... width 0..1PQ
.... high 1..1IVXB_TS
... subject 0..1Subject
... specimen 0..*Specimen
... performer 0..*Performer2
... author 0..*Author
... informant 0..*Informant
... participant 0..*Participant2
... reference 0..*Reference
... precondition 0..*Precondition
... sdtcPrecondition2 0..*Precondition2
... component 0..*OrganizerComponent

doco Documentation for this format