HL7 Czech Imaging Report IG, published by HL7 Czech Republic. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7-cz/img/ and changes regularly. See the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Composition/dbd426a9-d660-4f97-8656-1e39db4a57c9> a fhir:Composition ;
fhir:nodeRole fhir:treeRoot ;
fhir:Resource.id [ fhir:value "dbd426a9-d660-4f97-8656-1e39db4a57c9"] ;
fhir:Resource.meta [
fhir:Meta.profile [
fhir:value "https://hl7.cz/fhir/img/StructureDefinition/cz-composition-imaging" ;
fhir:index -1 ;
fhir:link <https://hl7.cz/fhir/img/StructureDefinition/cz-composition-imaging>
]
] ;
fhir:Resource.language [ fhir:value "en"] ;
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "extensions" ]
] ;
fhir:DomainResource.extension [
fhir:index -1 ;
fhir:Extension.url [ fhir:value "http://hl7.eu/fhir/extensions/StructureDefinition/composition-diagnosticReportReference" ] ;
fhir:Extension.valueReference [
fhir:Reference.reference [ fhir:value "urn:uuid:bd3e7b78-bfaa-428e-9168-8cd29cf54aba" ]
]
] ;
fhir:Composition.identifier [
fhir:Identifier.system [ fhir:value "http://example.org/myhospital/reportidentifiers" ] ;
fhir:Identifier.value [ fhir:value "dfkjewoieoijwoskdjg" ]
] ;
fhir:Composition.status [ fhir:value "final"] ;
fhir:Composition.type [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:24686-8 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "24686-8" ]
]
] ;
fhir:Composition.category [
fhir:index -1 ;
fhir:CodeableConcept.coding [
fhir:index -1 ;
fhir:Coding.system [ fhir:value "http://hl7.eu/fhir/health-data-api/CodeSystem/eehrxf-document-priority-category-cs" ] ;
fhir:Coding.code [ fhir:value "Medical-Imaging" ]
]
], [
fhir:index -1 ;
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:85430-7 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "85430-7" ]
]
] ;
fhir:Composition.subject [
fhir:Reference.reference [ fhir:value "urn:uuid:62d2aa9a-a15f-4e43-9458-fec16c1c4882" ]
] ;
fhir:Composition.date [ fhir:value "2025-05-20T12:02:00+01:00"^^xsd:dateTime] ;
fhir:Composition.author [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:aafd64f9-36ab-4583-8088-efb93b44db9b" ]
], [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:e96e9bd5-0695-4725-acb2-c731aa071a55" ]
] ;
fhir:Composition.title [ fhir:value "Imaging Report - Rentgen Ing. Králíka"] ;
fhir:Composition.confidentiality [ fhir:value "N"] ;
fhir:Composition.custodian [
fhir:Reference.reference [ fhir:value "urn:uuid:a4641bd0-34af-4038-a7db-872d08a54df9" ]
] ;
fhir:Composition.section [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Requested imaging studies information Document" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:55115-0 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "55115-0" ] ;
fhir:Coding.display [ fhir:value "Requested imaging studies information Document" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
] ;
fhir:Composition.section.entry [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:d6784779-d008-447d-90cf-89d5d53a0f04" ]
]
], [
fhir:index -1 ;
fhir:Element.extension [
fhir:index -1 ;
fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/note" ] ;
fhir:Extension.valueAnnotation [
fhir:Element.id [ fhir:value "clinical-question-note" ] ;
fhir:Annotation.text [ fhir:value "Trauma skeletu?" ]
]
] ;
fhir:Composition.section.title [ fhir:value "Klinická otázka" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:18785-6 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "18785-6" ] ;
fhir:Coding.display [ fhir:value "Radiology Reason for study (narrative)" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Obrazová studie" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:18726-0 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "18726-0" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
] ;
fhir:Composition.section.entry [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:fc79917b-b1b0-44a6-beaa-e9715322c834" ]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Procedura" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:55111-9 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "55111-9" ] ;
fhir:Coding.display [ fhir:value "Current imaging procedure descriptions Document" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
] ;
fhir:Composition.section.entry [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:ea2967a5-0d00-461c-8785-b5affef4791c" ]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Nálezy" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:59776-5 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "59776-5" ] ;
fhir:Coding.display [ fhir:value "Procedure findings Narrative" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
] ;
fhir:Composition.section.entry [
fhir:index -1 ;
fhir:Reference.reference [ fhir:value "urn:uuid:eca2bf34-9fa8-4abf-bd98-d8d49bcb1104" ]
]
], [
fhir:index -1 ;
fhir:Element.extension [
fhir:index -1 ;
fhir:Extension.url [ fhir:value "http://hl7.org/fhir/StructureDefinition/note" ] ;
fhir:Extension.valueAnnotation [
fhir:Element.id [ fhir:value "impression-note" ] ;
fhir:Annotation.text [ fhir:value "Nález byl negativní. Trauma skeletu nepotrvzeno." ]
]
] ;
fhir:Composition.section.title [ fhir:value "Výsledek" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:19005-8 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "19005-8" ] ;
fhir:Coding.display [ fhir:value "Radiology Imaging study [Impression] (narrative)" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "additional" ]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "History" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:11329-0 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "11329-0" ] ;
fhir:Coding.display [ fhir:value "History general Narrative - Reported" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "generated" ]
] ;
fhir:Composition.section.emptyReason [
fhir:CodeableConcept.coding [
fhir:index -1 ;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/list-empty-reason" ] ;
fhir:Coding.code [ fhir:value "nilknown" ] ;
fhir:Coding.display [ fhir:value "Nil Known" ]
]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Comparison" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:18834-2 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "18834-2" ] ;
fhir:Coding.display [ fhir:value "Radiology Comparison study (narrative)" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "generated" ]
] ;
fhir:Composition.section.emptyReason [
fhir:CodeableConcept.coding [
fhir:index -1 ;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/list-empty-reason" ] ;
fhir:Coding.code [ fhir:value "nilknown" ] ;
fhir:Coding.display [ fhir:value "Nil Known" ]
]
]
], [
fhir:index -1 ;
fhir:Composition.section.title [ fhir:value "Recommendations" ] ;
fhir:Composition.section.code [
fhir:CodeableConcept.coding [
fhir:index -1 ;
a loinc:18783-1 ;
fhir:Coding.system [ fhir:value "http://loinc.org" ] ;
fhir:Coding.code [ fhir:value "18783-1" ] ;
fhir:Coding.display [ fhir:value "Radiology Study recommendation (narrative)" ]
]
] ;
fhir:Composition.section.text [
fhir:Narrative.status [ fhir:value "generated" ]
] ;
fhir:Composition.section.emptyReason [
fhir:CodeableConcept.coding [
fhir:index -1 ;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/list-empty-reason" ] ;
fhir:Coding.code [ fhir:value "nilknown" ] ;
fhir:Coding.display [ fhir:value "Nil Known" ]
]
]
] .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Composition/dbd426a9-d660-4f97-8656-1e39db4a57c9.ttl> a owl:Ontology ;
owl:imports fhir:fhir.ttl ;
owl:versionIRI <http://build.fhir.org/Composition/dbd426a9-d660-4f97-8656-1e39db4a57c9.ttl> .
IG © 2025+ HL7 Czech Republic.
Package hl7.fhir.cz.img#1.0.0 based on FHIR 4.0.1.
Generated
2026-11-19
Links: Table of Contents |
QA Report