HL7 Czech Imaging Order IG
0.1.0-ballot - ballot Czechia flag

HL7 Czech Imaging Order IG, published by HL7 Czech Republic. This guide is not an authorized publication; it is the continuous build for version 0.1.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7-cz/img-order/ and changes regularly. See the Directory of published versions

Resource Profile: Device Use Statement: Imaging Order (CZ)

Official URL: https://hl7.cz/fhir/img-order/StructureDefinition/cz-deviceUseStatement Version: 0.1.0-ballot
Draft as of 2025-08-28 Computable Name: CZ_DeviceUseStatement

This profile represents the constraints applied to the DeviceUseStatement resource for the purpose of this guide. A device used by or implanted on the patient is described in the imaging order as an instance of a Device resource constrained by this profile.

Usages:

You can also check for usages in the FHIR IG Statistics

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement 0..* DeviceUseStatement Record of use of a device
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Device usage description
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... subject Σ 1..1 Reference(Patient (CZ core)) Patient using device
... timing[x] Σ 1..1 How often the device was used
.... timing[x]All Types Content/Rules for all Types
..... Slices for extension Content/Rules for all slices
...... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
.... timingTiming Timing
.... timingPeriod Period
.... timingDateTime dateTime
... device Σ 1..1 Reference(Medical Device (CZ)) Reference to device used
... reasonCode Σ 0..* CodeableConcept Why is used (code)
... reasonReference Σ 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite Σ 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
DeviceUseStatement.statusrequiredDeviceUseStatementStatus
http://hl7.org/fhir/ValueSet/device-statement-status|4.0.1
From the FHIR Standard
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceUseStatementIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceUseStatementIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceUseStatementA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from DeviceUseStatement

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement DeviceUseStatement
... text 0..1 Narrative Device usage description
... subject 1..1 Reference(Patient (CZ core)) Patient using device
... timing[x] 1..1 Timing, Period, dateTime How often the device was used
.... Slices for extension Content/Rules for all slices
..... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
... reasonCode 0..* CodeableConcept Why is used (code)
... reasonReference 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard
NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement 0..* DeviceUseStatement Record of use of a device
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Device usage description
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier External identifier for this record
... basedOn Σ 0..* Reference(ServiceRequest) Fulfills plan, proposal or order
... status ?!Σ 1..1 code active | completed | entered-in-error +
Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage.
... subject Σ 1..1 Reference(Patient (CZ core)) Patient using device
... derivedFrom Σ 0..* Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference) Supporting information
... timing[x] Σ 1..1 How often the device was used
.... timing[x]All Types Content/Rules for all Types
..... id 0..1 string Unique id for inter-element referencing
..... Slices for extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
.... timingTiming Timing
.... timingPeriod Period
.... timingDateTime dateTime
... recordedOn Σ 0..1 dateTime When statement was recorded
... source Σ 0..1 Reference(Patient | Practitioner | PractitionerRole | RelatedPerson) Who made the statement
... device Σ 1..1 Reference(Medical Device (CZ)) Reference to device used
... reasonCode Σ 0..* CodeableConcept Why is used (code)
... reasonReference Σ 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite Σ 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)
... note 0..* Annotation Addition details (comments, instructions)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
DeviceUseStatement.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
From the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
DeviceUseStatement.statusrequiredDeviceUseStatementStatus
http://hl7.org/fhir/ValueSet/device-statement-status|4.0.1
From the FHIR Standard
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceUseStatementIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceUseStatementIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceUseStatementA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

Key Elements View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement 0..* DeviceUseStatement Record of use of a device
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Device usage description
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... subject Σ 1..1 Reference(Patient (CZ core)) Patient using device
... timing[x] Σ 1..1 How often the device was used
.... timing[x]All Types Content/Rules for all Types
..... Slices for extension Content/Rules for all slices
...... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
.... timingTiming Timing
.... timingPeriod Period
.... timingDateTime dateTime
... device Σ 1..1 Reference(Medical Device (CZ)) Reference to device used
... reasonCode Σ 0..* CodeableConcept Why is used (code)
... reasonReference Σ 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite Σ 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
DeviceUseStatement.statusrequiredDeviceUseStatementStatus
http://hl7.org/fhir/ValueSet/device-statement-status|4.0.1
From the FHIR Standard
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceUseStatementIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceUseStatementIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceUseStatementA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

Differential View

This structure is derived from DeviceUseStatement

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement DeviceUseStatement
... text 0..1 Narrative Device usage description
... subject 1..1 Reference(Patient (CZ core)) Patient using device
... timing[x] 1..1 Timing, Period, dateTime How often the device was used
.... Slices for extension Content/Rules for all slices
..... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
... reasonCode 0..* CodeableConcept Why is used (code)
... reasonReference 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard

Snapshot View

NameFlagsCard.TypeDescription & Constraints    Filter: Filtersdoco
.. DeviceUseStatement 0..* DeviceUseStatement Record of use of a device
... id Σ 0..1 id Logical id of this artifact
... meta Σ 0..1 Meta Metadata about the resource
... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
... text 0..1 Narrative Device usage description
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... contained 0..* Resource Contained, inline Resources
... extension 0..* Extension Additional content defined by implementations
... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
... identifier Σ 0..* Identifier External identifier for this record
... basedOn Σ 0..* Reference(ServiceRequest) Fulfills plan, proposal or order
... status ?!Σ 1..1 code active | completed | entered-in-error +
Binding: DeviceUseStatementStatus (required): A coded concept indicating the current status of the Device Usage.
... subject Σ 1..1 Reference(Patient (CZ core)) Patient using device
... derivedFrom Σ 0..* Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference) Supporting information
... timing[x] Σ 1..1 How often the device was used
.... timing[x]All Types Content/Rules for all Types
..... id 0..1 string Unique id for inter-element referencing
..... Slices for extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
...... extension:data-absent-reason 0..1 code unknown | asked | temp | notasked | masked | unsupported | astext | error
URL: http://hl7.org/fhir/StructureDefinition/data-absent-reason
Binding: DataAbsentReason (required): Used to specify why the normally expected content of the data element is missing.
.... timingTiming Timing
.... timingPeriod Period
.... timingDateTime dateTime
... recordedOn Σ 0..1 dateTime When statement was recorded
... source Σ 0..1 Reference(Patient | Practitioner | PractitionerRole | RelatedPerson) Who made the statement
... device Σ 1..1 Reference(Medical Device (CZ)) Reference to device used
... reasonCode Σ 0..* CodeableConcept Why is used (code)
... reasonReference Σ 0..* Reference(Condition | Observation: Imaging Order (CZ) | Media | DiagnosticReport | DocumentReference) Why is used (details)
... bodySite Σ 0..1 CodeableConcept Target body site
Binding: SNOMEDCTBodyStructures (preferred)
... note 0..* Annotation Addition details (comments, instructions)

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
DeviceUseStatement.languagepreferredCommonLanguages
http://hl7.org/fhir/ValueSet/languages
From the FHIR Standard
Additional Bindings Purpose
AllLanguages Max Binding
DeviceUseStatement.statusrequiredDeviceUseStatementStatus
http://hl7.org/fhir/ValueSet/device-statement-status|4.0.1
From the FHIR Standard
DeviceUseStatement.bodySitepreferredSNOMEDCTBodyStructures
http://hl7.org/fhir/ValueSet/body-site
From the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceUseStatementIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceUseStatementIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceUseStatementIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceUseStatementA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

 

Other representations of profile: CSV, Excel, Schematron