Quality Checks |
Publisher Version: | IG Publisher Version: v1.6.11 |
Publication Code: | n/a . PackageId = hl7.fhir.cz.core, Canonical = https://hl7.cz/fhir/core |
Realm Check for n/a: | |
Publication Request: | - Error fetching package-list from https://hl7.cz/fhir/core: Connect timed out
- No publication request found
|
Supressed Messages: | No Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.fhir.cz.core | 0.1.0 | R4 | https://hl7.cz/fhir/core | | |
hl7.terminology.r4 | 5.5.0 M | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.5.0 | |
hl7.fhir.uv.extensions.r4 | 5.1.0 M | R4 | http://hl7.org/fhir/extensions | http://hl7.org/fhir/extensions/5.1.0 | |
hl7.fhir.uv.ips | 1.1.0 M | R4 | http://hl7.org/fhir/uv/ips | http://hl7.org/fhir/uv/ips/STU1.1 | |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | Latest Release is 5.5.0 |
fhir.dicom | 2022.4.20221006 O | R4 | http://fhir.org/packages/fhir.dicom | http://fhir.org/packages/fhir.dicom | Latest Release is 2024.2.20240331 |
Templates: fhir.base.template#current. Tools: 0.1.0 |
Dependent IGs: | no references |
Global Profiles: | (none declared) |
Terminology Server(s): | http://tx.fhir.org/r4 (details) |
HTA Analysis: | All OK |
R5 Dependencies: | (none) |
Draft Dependencies: |
-
hl7.fhir.r4.core#4.0.1: GuideParameterCode
(15 uses), Shareable CodeSystem
(3 uses), regex
(6 uses), Organization
(24 uses), SC-coding
(3 uses), Device
(4 uses), CommonLanguages
(10 uses), DeviceDefinition
(2 uses), UDIEntryType
(2 uses), FHIRDeviceStatus
(2 uses), FHIRDeviceStatusReason
(2 uses), DeviceNameType
(2 uses), DeviceType
(1 uses), Location
(3 uses), OrganizationType
(1 uses), ContactEntityType
(1 uses), Endpoint
(2 uses), Practitioner
(2 uses), PractitionerRole
(2 uses), RelatedPerson
(2 uses), PractitionerRole
(1 uses), HealthcareService
(1 uses), Shareable ValueSet
(1 uses)
-
hl7.fhir.uv.extensions.r4#5.1.0: PatSexParameterForClinicalUse
(2 uses)
-
hl7.fhir.uv.tools#0.2.0: ResourceSortExt
(41 uses)
|
Modifier Extensions: | (none) |
Previous Version Comparison: | Unable to compare with previous version: Unable to find version history at https://hl7.cz/fhir/core (Problem #1 with package-list.json at https://hl7.cz/fhir/core: Connect timed out) |
IPA Comparison: | n/a |
IPS Comparison: | n/a |
Summary: | errors = 9, warn = 0, info = 0, broken links = 10 |
StructureDefinition-cz-patient.html | error | The reference integer64 could not be resolved |
StructureDefinition-cz-patient.html | error | The reference CodeableReference could not be resolved |
StructureDefinition-cz-patient.html | error | The reference RatioRange could not be resolved |
StructureDefinition-cz-patient.html | error | The reference Availability could not be resolved |
StructureDefinition-cz-patient.html | error | The reference ExtendedContactDetail could not be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 470, column 1592 | error | The link 'integer64.html' for "integer64" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 470, column 3102 | error | The link 'CodeableReference.html' for "CodeableReference" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 470, column 4424 | error | The link 'RatioRange.html' for "RatioRange" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 470, column 5764 | error | The link 'Availability.html' for "Availability" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 470, column 5810 | error | The link 'ExtendedContactDetail.html' for "ExtendedContactDetail" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 883, column 1088 | error | The link 'integer64.html' for "integer64" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 883, column 2094 | error | The link 'CodeableReference.html' for "CodeableReference" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 883, column 2984 | error | The link 'RatioRange.html' for "RatioRange" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 883, column 3928 | error | The link 'Availability.html' for "Availability" cannot be resolved |
output/StructureDefinition-cz-patient-definitions.html#/html/body/div/div/div/div/div/div/div/table/tr/td/a at Line 883, column 3974 | error | The link 'ExtendedContactDetail.html' for "ExtendedContactDetail" cannot be resolved |
Path | Severity | Message |
Patient.extension[1].extension[1].value.ofType(CodeableConcept).coding[0].display (l69/c12) | error | Wrong Display Name 'Všeobecné lékařské služby' for http://snomed.info/sct#700232004. Valid display is one of 2 choices: 'General medical service' or 'General medical service (qualifier value)' (for the language(s) 'cs') (from http://tx.fhir.org/r4) |
Patient.extension[1].extension[1].value.ofType(CodeableConcept) (l69/c12) | error | None of the codings provided are in the value set 'Typ registrujícího lékaře / Type of registering physician' (https://ncez.mzcr.cz/fhir/ValueSet/typ-registrujiciho-lekare-vs|0.1.0), and a coding from this value set is required) (codes = http://snomed.info/sct#700232004) |
Patient.extension[2].extension[1].value.ofType(CodeableConcept).coding[0].display (l92/c12) | error | Wrong Display Name 'Gynekologické a porodnické služby' for http://snomed.info/sct#310060005. Valid display is one of 3 choices: 'Obstetrics and gynecology service', 'Obstetrics and gynaecology service' or 'Obstetrics and gynecology service (qualifier value)' (for the language(s) 'cs') (from http://tx.fhir.org/r4) |
Patient.extension[2].extension[1].value.ofType(CodeableConcept) (l92/c12) | error | None of the codings provided are in the value set 'Typ registrujícího lékaře / Type of registering physician' (https://ncez.mzcr.cz/fhir/ValueSet/typ-registrujiciho-lekare-vs|0.1.0), and a coding from this value set is required) (codes = http://snomed.info/sct#310060005) |