Unable to compare with previous version: Unable to find version history at http://hl7.org.pl/fhir/ig/pl-terminology (Problem #1 with package-list.json at http://hl7.org.pl/fhir/ig/pl-terminology: null)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
3
warning
An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4
warning
The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-dischargeDisposition-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-dischargeDisposition-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem
error
CodeSystem http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS has an 'all system' value set of http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS, but the value set doesn't have a matching system (http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS)CodeSystem_CS_VS_WrongSystem
--
CodeSystem (l1/c4209)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c4209)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c4209)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-dischargeDisposition-CS vs http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalEntityCellType-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalEntityCellType-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
A definition could not be found for Canonical URL 'http://hl7.org.pl/fhir/ValueSet/pl-medicalEntityCellType-VS'TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem (l1/c76779)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c76779)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c76779)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalEntityCellType-CS vs http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalPracticeIdentifierPool-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalPracticeIdentifierPool-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalPracticeIdentifierPool-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem (l1/c29010)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c29010)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c29010)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalPracticeIdentifierPool-CS vs http://hl7.org.pl/fhir/CodeSystem/pl-medicalPracticeIdentifierPool-CS
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalProfession-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalProfession-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalProfession-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem (l1/c2801)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c2801)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c2801)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-practitionerSpecialty-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-practitionerSpecialty-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-practitionerSpecialty-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem (l1/c15281)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c15281)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c15281)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-practitionerSpecialty-CS vs http://hl7.org.pl/fhir/CodeSystem/pl-practitionerSpecialty-CS
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-reimbursementContractIdentifierPool-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-reimbursementContractIdentifierPool-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-reimbursementContractIdentifierPool-CS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)CODESYSTEM_THO_CHECK
--
CodeSystem
warning
HL7 Defined CodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearlyCODESYSTEM_CS_HL7_MISSING_ELEMENT_SHOULD
--
CodeSystem (l1/c21385)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem (l1/c21385)
error
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not presentCODESYSTEM_SHAREABLE_MISSING_HL7
--
CodeSystem.concept[0] (l1/c21385)
warning
HL7 Defined CodeSystems should ensure that every concept has a definitionCODESYSTEM_CONCEPT_NO_DEFINITION
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-reimbursementContractIdentifierPool-CS vs http://hl7.org.pl/fhir/CodeSystem/pl-reimbursementContractIdentifierPool-CS
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Constraint failed: cnl-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation (name.exists() implies name.matches('^[A-Z]([A-Za-z0-9_]){1,254}$'))' (defined in http://hl7.org/fhir/StructureDefinition/ImplementationGuide)http://hl7.org/fhir/StructureDefinition/ImplementationGuide#cnl-0
Conformance resource /scratch/repo/fsh-generated/resources/StructureDefinition-pl-base-codeSystem.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-codeSystem) does not match the URL (http://hl7.org.pl/fhir/StructureDefinition/pl-base-codeSystem). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
The definition for the element 'CodeSystem.versionAlgorithm[x]' binds to the value set 'http://hl7.org/fhir/ValueSet/version-algorithm|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'CodeSystem.jurisdiction' binds to the value set 'http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'CodeSystem.content' binds to the value set 'http://hl7.org/fhir/ValueSet/codesystem-content-mode|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-codeSystem vs http://hl7.org.pl/fhir/StructureDefinition/pl-base-codeSystem
Conformance resource /scratch/repo/fsh-generated/resources/StructureDefinition-pl-base-valueSet.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-valueSet) does not match the URL (http://hl7.org.pl/fhir/StructureDefinition/pl-base-valueSet). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
The definition for the element 'ValueSet.versionAlgorithm[x]' binds to the value set 'http://hl7.org/fhir/ValueSet/version-algorithm|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
The definition for the element 'ValueSet.jurisdiction' binds to the value set 'http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0' which is experimental, but this structure is not labeled as experimentalSD_ED_EXPERIMENTAL_BINDING
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-valueSet vs http://hl7.org.pl/fhir/StructureDefinition/pl-base-valueSet
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-administrativeGender-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-administrativeGender-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-administrativeGender-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-administrativeGender-VS vs http://hl7.org.pl/fhir/ValueSet/pl-administrativeGender-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-ageUnit-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-ageUnit-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-ageUnit-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
--
fsh-generated/resources/ValueSet-pl-ageUnit-VS
error
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-ageUnit-VS vs http://hl7.org.pl/fhir/ValueSet/pl-ageUnit-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-confidentialityCode-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-confidentialityCode-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-confidentialityCode-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://terminology.hl7.org/CodeSystem/v3-Confidentiality to 4.0.0 from choices of 3.0.0 (hl7.terminology.r5#7.0.1), 4.0.0 (hl7.terminology.r5#7.1.0)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-discharge-disposition-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-discharge-disposition-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
--
Resource
warning
The URL 'http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS' is also used by pl-medicalEntityCellType-VS in /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalEntityCellType-VS
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-discharge-disposition-VS vs http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-documentLanguage-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-documentLanguage-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-documentLanguage-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Wrong Display Name 'British English' for urn:ietf:bcp:47#en-GB. Valid display is one of 5 choices: 'English (United Kingdom)' (en), 'English (Region=United Kingdom)' (en), 'English-United Kingdom' (en), 'English-UNITED KINGDOM' (en) or 'English (United Kingdom)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'American English' for urn:ietf:bcp:47#en-US. Valid display is one of 5 choices: 'English (United States)' (en), 'English (Region=United States)' (en), 'English-United States' (en), 'English-UNITED STATES' (en) or 'English (United States)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Polish' for urn:ietf:bcp:47#pl-PL. Valid display is one of 5 choices: 'Polish (Poland)' (en), 'Polish (Region=Poland)' (en), 'Polish-Poland' (en), 'Polish-POLAND' (en) or 'Polish (Poland)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet (l1/c2143)
error
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalEntityCellType-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalEntityCellType-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
--
Resource
warning
The URL 'http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS' has already been used by pl-discharge-disposition-VS in /scratch/repo/fsh-generated/resources/ValueSet-pl-discharge-disposition-VS
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalEntityCellType-VS vs http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalPracticeIdentifierPool-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalPracticeIdentifierPool-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-medicalPracticeIdentifierPool-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalPracticeIdentifierPool-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalPracticeIdentifierPool-VS vs http://hl7.org.pl/fhir/ValueSet/pl-medicalPracticeIdentifierPool-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalProfession-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalProfession-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-medicalProfession-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalProfession-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-practitionerSpecialty-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-practitionerSpecialty-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-practitionerSpecialty-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-practitionerSpecialty-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-practitionerSpecialty-VS vs http://hl7.org.pl/fhir/ValueSet/pl-practitionerSpecialty-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-reimbursementContractIdentifierPool-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-reimbursementContractIdentifierPool-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-reimbursementContractIdentifierPool-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
ValueSet.compose.include[0]
information
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-reimbursementContractIdentifierPool-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)PIN_VERSION
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-reimbursementContractIdentifierPool-VS vs http://hl7.org.pl/fhir/ValueSet/pl-reimbursementContractIdentifierPool-VS
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-timeUnit-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-timeUnit-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-timeUnit-VS). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display (from https://tx.fhir.org/r5) NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not presentVALUESET_SHAREABLE_MISSING_HL7
--
fsh-generated/resources/ValueSet-pl-timeUnit-VS
error
URL Mismatch http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-timeUnit-VS vs http://hl7.org.pl/fhir/ValueSet/pl-timeUnit-VS
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
Code systems published by HL7 SHALL conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
Most code systems defined in HL7 IGs will need to move to THO later during the process. Consider giving this code system a THO URL now (See https://confluence.hl7.org/display/TSMG/Terminology+Play+Book, and/or talk to TSMG)
CodeSystem http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS has an 'all system' value set of http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS, but the value set doesn't have a matching system (http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS)
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
There are no valid display names found for the code urn:iso:std:iso:3166#PL for language(s) 'pl-PL'. The display is 'Poland' which is the default language display
Pinned the version of http://terminology.hl7.org/CodeSystem/v3-Confidentiality to 4.0.0 from choices of 3.0.0 (hl7.terminology.r5#7.0.1), 4.0.0 (hl7.terminology.r5#7.1.0)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalPracticeIdentifierPool-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-medicalProfession-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-practitionerSpecialty-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Pinned the version of http://hl7.org.pl/fhir/CodeSystem/pl-reimbursementContractIdentifierPool-CS to 0.1.5 from choices of 0.1.0 (hl7.fhir.pl.terminology#0.1.0), 0.1.5 (hl7.fhir.pl.base.r5#0.1.5)
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-dischargeDisposition-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-dischargeDisposition-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-dischargeDisposition-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalEntityCellType-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalEntityCellType-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalEntityCellType-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalPracticeIdentifierPool-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalPracticeIdentifierPool-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalPracticeIdentifierPool-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-medicalProfession-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-medicalProfession-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-medicalProfession-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-practitionerSpecialty-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-practitionerSpecialty-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-practitionerSpecialty-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-pl-reimbursementContractIdentifierPool-CS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/CodeSystem/pl-reimbursementContractIdentifierPool-CS) does not match the URL (http://hl7.org.pl/fhir/CodeSystem/pl-reimbursementContractIdentifierPool-CS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/StructureDefinition-pl-base-codeSystem.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-codeSystem) does not match the URL (http://hl7.org.pl/fhir/StructureDefinition/pl-base-codeSystem). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/StructureDefinition-pl-base-valueSet.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/StructureDefinition/pl-base-valueSet) does not match the URL (http://hl7.org.pl/fhir/StructureDefinition/pl-base-valueSet). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-administrativeGender-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-administrativeGender-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-administrativeGender-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-ageUnit-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-ageUnit-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-ageUnit-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-confidentialityCode-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-confidentialityCode-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-confidentialityCode-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-discharge-disposition-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-discharge-disposition-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-documentLanguage-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-documentLanguage-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-documentLanguage-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalEntityCellType-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalEntityCellType-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-dischargeDisposition-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalPracticeIdentifierPool-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalPracticeIdentifierPool-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-medicalPracticeIdentifierPool-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-medicalProfession-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-medicalProfession-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-medicalProfession-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-practitionerSpecialty-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-practitionerSpecialty-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-practitionerSpecialty-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-reimbursementContractIdentifierPool-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-reimbursementContractIdentifierPool-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-reimbursementContractIdentifierPool-VS). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-pl-timeUnit-VS.json - the canonical URL (http://hl7.org.pl/fhir/ig/pl-terminology/ValueSet/pl-timeUnit-VS) does not match the URL (http://hl7.org.pl/fhir/ValueSet/pl-timeUnit-VS). Use the special-url parameter if you really mean for it not to match
The definition for the element 'CodeSystem.versionAlgorithm[x]' binds to the value set 'http://hl7.org/fhir/ValueSet/version-algorithm|5.0.0' which is experimental, but this structure is not labeled as experimental
The definition for the element 'CodeSystem.jurisdiction' binds to the value set 'http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0' which is experimental, but this structure is not labeled as experimental
The definition for the element 'CodeSystem.content' binds to the value set 'http://hl7.org/fhir/ValueSet/codesystem-content-mode|5.0.0' which is experimental, but this structure is not labeled as experimental
The definition for the element 'ValueSet.versionAlgorithm[x]' binds to the value set 'http://hl7.org/fhir/ValueSet/version-algorithm|5.0.0' which is experimental, but this structure is not labeled as experimental
The definition for the element 'ValueSet.jurisdiction' binds to the value set 'http://hl7.org/fhir/ValueSet/jurisdiction|5.0.0' which is experimental, but this structure is not labeled as experimental
Wrong Display Name 'British English' for urn:ietf:bcp:47#en-GB. Valid display is one of 5 choices: 'English (United Kingdom)' (en), 'English (Region=United Kingdom)' (en), 'English-United Kingdom' (en), 'English-UNITED KINGDOM' (en) or 'English (United Kingdom)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'American English' for urn:ietf:bcp:47#en-US. Valid display is one of 5 choices: 'English (United States)' (en), 'English (Region=United States)' (en), 'English-United States' (en), 'English-UNITED STATES' (en) or 'English (United States)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Polish' for urn:ietf:bcp:47#pl-PL. Valid display is one of 5 choices: 'Polish (Poland)' (en), 'Polish (Region=Poland)' (en), 'Polish-Poland' (en), 'Polish-POLAND' (en) or 'Polish (Poland)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Value sets published by HL7 SHALL conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present