Canadian Baseline
1.2.0 - CI Build Canada flag

Canadian Baseline, published by HL7 Canada - FHIR Implementation Work Group. This guide is not an authorized publication; it is the continuous build for version 1.2.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7-Canada/ca-baseline/ and changes regularly. See the Directory of published versions

Resource Profile: DeviceProfile - Detailed Descriptions

Draft as of 2024-12-27

Definitions for the profile-device resource profile.

Guidance on how to interpret the contents of this table can be found here

0. Device
Definition

The Device Profile is based upon the core FHIR Device Resource


A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.

ShortDevice ProfileItem used in healthcare
Control0..*
Is Modifierfalse
Summaryfalse
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
ca-device-1: Implantable medical devices that have UDI information MAY represent this information in either carrierAIDC or carrierHRF. (udiCarrier.empty() or (udiCarrier.carrierAIDC.exists() or udiCarrier.carrierHRF.exists()))
ca-device-2: For implantable medical devices that have UDI information, at least one of the Production Identifiers (UDI-PI) MAY be present. (udiCarrier.empty() or (manufactureDate.exists() or expirationDate.exists() or lotNumber.exists() or serialNumber.exists() or distinctIdentifier.exists()))
2. Device.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Device.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Device.udiCarrier
Definition

Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold.

ShortUnique Device Identifier (UDI) Barcode string
Comments

UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.


UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.

Control10..1*
TypeBackboneElement
Is Modifierfalse
Must Supporttrue
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
8. Device.udiCarrier.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
10. Device.udiCarrier.deviceIdentifier
Definition

The device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device.

ShortMandatory fixed portion of UDI
Control10..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summarytrue
Alternate NamesDI
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
12. Device.udiCarrier.carrierAIDC
Definition

The full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded.

ShortUDI Machine Readable Barcode String
Comments

The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.

Control0..1
Typebase64Binary
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summarytrue
Alternate NamesAutomatic Identification and Data Capture
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
14. Device.udiCarrier.carrierHRF
Definition

The full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device.

ShortUDI Human Readable Barcode String
Comments

If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.

Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summarytrue
Alternate NamesHuman Readable Form
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
16. Device.status
Definition

Status of the Device availability.

Shortactive | inactive | entered-in-error | unknown
Comments

This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid.

Control0..1
BindingThe codes SHALL be taken from FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1
(required to http://hl7.org/fhir/ValueSet/device-status|4.0.1)

The availability status of the device.

Typecode
Is Modifiertrue because This element is labelled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
18. Device.distinctIdentifier
Definition

The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product.

ShortThe distinct identification string
Comments

For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).

Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summaryfalse
Alternate NamesDistinct Identification Code (DIC)
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
20. Device.manufacturer
Definition

A name of the manufacturer.

ShortName of device manufacturer
Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
22. Device.expirationDate
Definition

The date and time beyond which this device is no longer valid or should not be used (if applicable).

ShortDate and time of expiry of this device (if applicable)
Control0..1
TypedateTime
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
24. Device.lotNumber
Definition

Lot number assigned by the manufacturer.

ShortLot number of manufacture
Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
26. Device.serialNumber
Definition

The serial number assigned by the organization when the device was manufactured.

ShortSerial number assigned by the manufacturer
Comments

Alphanumeric Maximum 20.

Control0..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
28. Device.deviceName
Definition

This represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.

ShortThe name of the device as given by the manufacturer
Control0..*
TypeBackboneElement
Is Modifierfalse
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
30. Device.deviceName.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
32. Device.deviceName.name
Definition

The name of the device.

ShortThe name of the device
Control1..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summaryfalse
Alternate NamesΣ
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
34. Device.deviceName.type
Definition

The type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName.

Shortudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Control1..1
BindingThe codes SHALL be taken from DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1
(required to http://hl7.org/fhir/ValueSet/device-nametype|4.0.1)

The type of name the device is referred by.

Typecode
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
36. Device.type
Definition

The kind or type of device.

ShortThe kind or type of device
Comments

The device-kind and device-type valueSets used in HL7 are identical. This profile currently mainatins the binding on device-kind because it is currently hosted in THO and is therefor expected to be updated more frequently

Control10..1
BindingUnless not suitable, these codes SHALL be taken from For example codes, see FHIR Device Typeshttp://hl7.org/fhir/ValueSet/device-type
(extensible to http://terminology.hl7.org/ValueSet/device-kind)

Codes to identify medical devices


Codes to identify medical devices.

TypeCodeableConcept
Is Modifierfalse
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
38. Device.version
Definition

The actual design of the device or software version running on the device.

ShortThe actual design of the device or software version running on the device
NoteThis is a business version Id, not a resource version Id (see discussion)
Control0..*
TypeBackboneElement
Is Modifierfalse
Must Supporttrue
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
40. Device.version.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored even if unrecognized
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
Summarytrue
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content, modifiers
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
42. Device.version.value
Definition

The version text.

ShortThe version text
Control1..1
Typestring
Is Modifierfalse
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
44. Device.patient
Definition

Patient information, If the device is affixed to a person.

ShortPatient to whom Device is affixed
Control10..1
TypeReference(Patient Profile, Patient)
Is Modifierfalse
Summaryfalse
Requirements

If the device is implanted in a patient, then need to associate the device to the patient.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
46. Device.parent
Definition

The parent device.

ShortThe parent device
Control0..1
TypeReference(Device Profile (Implantable), Device)
Is Modifierfalse
Summaryfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))