Australian Digital Health Agency FHIR Implementation Guide
1.2.0-ci-build - draft Australia flag

Australian Digital Health Agency FHIR Implementation Guide, published by Australian Digital Health Agency. This guide is not an authorized publication; it is the continuous build for version 1.2.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/AuDigitalHealth/ci-fhir-r4/ and changes regularly. See the Directory of published versions

: Observation of SARS-CoV-2 RNA - Not Detected recorded for Mrs. Anne Thompson - XML Representation

Raw xml | Download



<Observation xmlns="http://hl7.org/fhir">
  <id value="covid-01"/>
  <meta>
    <profile
             value="http://ns.electronichealth.net.au/fhir/StructureDefinition/dh-observation-diagnosticresult-1"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation covid-01</b></p><a name="covid-01"> </a><a name="hccovid-01"> </a><a name="covid-01-en-AU"> </a><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category laboratory}">Laboratory</span>, <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0074 MB}">Microbiology</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 94309-2}">2019-Novel Coronavirus PCR</span></p><p><b>subject</b>: <a href="Patient-mhr-anne-thompson.html">Mrs. Anne Thompson(official) Female, DoB: 1978-10-11 ( IHI: AustalianIHI#8003608000228445)</a></p><p><b>effective</b>: 2021-02-15 12:00:00+1000</p><p><b>performer</b>: <a href="Organization-metro-qld-path-lab.html">Organization Metropolitan Pathology QLD</a></p><p><b>value</b>: <span title="Codes:{http://snomed.info/sct 260415000}">Not detected</span></p><p><b>note</b>: Doomben Pathology QLD NATA/RCPA accreditation does not cover the SARS-CoV-2 (COVID-19) PCR test., This test is currently under evaluation and has not been fully validated. Failure to detect organism-specific nucleic acids does not exclude the presence of disease due to this agent.</p><p><b>specimen</b>: <a href="Specimen-naso-swab-01.html">Specimen: type = Swab; note = Collection Setting COVID HSC Assessment Clinic</a></p></div>
  </text>
  <status value="final"/>
  <category>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/observation-category"/>
      <code value="laboratory"/>
    </coding>
  </category>
  <category>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/v2-0074"/>
      <code value="MB"/>
    </coding>
  </category>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="94309-2"/>
    </coding>
    <text value="2019-Novel Coronavirus PCR"/>
  </code>
  <subject>🔗 
    <reference value="Patient/mhr-anne-thompson"/>
    <identifier>
      <type>
        <coding>
          <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
          <code value="NI"/>
          <display value="National unique individual identifier"/>
        </coding>
        <text value="IHI"/>
      </type>
      <system value="http://ns.electronichealth.net.au/id/hi/ihi/1.0"/>
      <value value="8003608000228445"/>
    </identifier>
  </subject>
  <effectiveDateTime value="2021-02-15T12:00:00+10:00"/>
  <performer>🔗 
    <reference value="Organization/metro-qld-path-lab"/>
  </performer>
  <valueCodeableConcept>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="260415000"/>
      <display value="Not detected"/>
    </coding>
    <text value="Not detected"/>
  </valueCodeableConcept>
  <note>
    <text
          value="Doomben Pathology QLD NATA/RCPA accreditation does not cover the SARS-CoV-2 (COVID-19) PCR test."/>
  </note>
  <note>
    <text
          value="This test is currently under evaluation and has not been fully validated. Failure to detect organism-specific nucleic acids does not exclude the presence of disease due to this agent."/>
  </note>
  <specimen>🔗 
    <reference value="Specimen/naso-swab-01"/>
  </specimen>
</Observation>