This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Nonin20601PulseOx
{ "resourceType" : "Device", "id" : "Nonin20601PulseOx", "identifier" : [{ "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "SYSID", "display" : "System Identifier" }] }, "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680", "value" : "00-1C-05-04-00-00-78-25" }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "BTMAC", "display" : "Bluetooth Address" }] }, "system" : "http://hl7.org/fhir/sid/eui-48", "value" : "00-1C-05-00-78-25" }], "udiCarrier" : [{ "deviceIdentifier" : "120343001125", "issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di", "jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierHRF" : "(01)120343001125(21)0400007825", "entryType" : "unknown" }], "manufacturer" : "Nonin Medical, Inc.", "serialNumber" : "0400007825", "name" : [{ "value" : "Nonin_Medical_Inc._323552", "type" : { "coding" : [{ "system" : "http://hl7.org/fhir/device-nametype", "code" : "user-friendly-name" }] } }], "modelNumber" : "Model 3150", "type" : [{ "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "65573", "display" : "MDC_MOC_VMS_MDS_SIMP" }], "text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" }], "deviceVersion" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "531976" }], "text" : "MDC_ID_PROD_SPEC_FW: Firmware revision" }, "value" : "0.9C" }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532352" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" }, "value" : "1.0" }], "conformsTo" : [{ "specification" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "528388" }], "text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" }, "version" : "1" }], "property" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532353" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN", "code" : "4" }] } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "532354.0" }], "text" : "regulation-status" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "N" }], "text" : "Device is Regulated" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68220" }], "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" }, "valueCodeableConcept" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532224" }], "text" : "MDC_TIME_SYNC_NONE: No time synchronization" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.0" }], "text" : "mds-time-capab-real-time-clock" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "real time clock supported" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.2" }], "text" : "mds-time-capab-set-clock" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "setting the time supported" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.2" }], "text" : "mds-time-capab-relative-time" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "relative time supported" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68222" }], "text" : "MDC_TIME_RES_ABS: Resolution of absolute time clock" }, "valueQuantity" : { "value" : 1000000, "system" : "http://unitsofmeasure.org", "code" : "us" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68222" }], "text" : "MDC_TIME_RES_REL: Resolution of relative time clock" }, "valueQuantity" : { "value" : 1000000, "system" : "http://unitsofmeasure.org", "code" : "us" } }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Thu, Dec 12, 2024 19:28+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change