FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example Device/AndroidGatewayPHG (Narrative)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Device.


Generated Narrative: Device

Resource Device "AndroidGatewayPHG"

identifier: System Identifier/4C-4E-49-12-34-56-FF-FF

type: MDC_MOC_VMS_MDS_AHD: Continua compliant Gateway (ISO 11073-10101 Health informatics - Point-of-care#531981 "MDC_MOC_VMS_MDS_AHD")

Versions

-TypeValue
*MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version (ISO 11073-10101 Health informatics - Point-of-care#532352)6.0

property

type: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list (ISO 11073-10101 Health informatics - Point-of-care#532353)

value: 4 (ContinuaPAN#4)

property

type: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list (ISO 11073-10101 Health informatics - Point-of-care#532355)

value: 0 (ContinuaHFS#0)

property

type: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list (ISO 11073-10101 Health informatics - Point-of-care#532355)

value: 3 (ContinuaHFS#3)

property

type: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list (ISO 11073-10101 Health informatics - Point-of-care#532355)

value: 7 (ContinuaHFS#7)

property

type: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list (ISO 11073-10101 Health informatics - Point-of-care#532355)

value: 2 (ContinuaHFS#2)

property

type: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list (ISO 11073-10101 Health informatics - Point-of-care#532355)

value: 6 (ContinuaHFS#6)

property

type: regulation-status (ASN1ToHL7#532354.0)

value: Device is Unregulated (v2-0136#Y)

property

type: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol (ISO 11073-10101 Health informatics - Point-of-care#68220)

value: MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization (ISO 11073-10101 Health informatics - Point-of-care#532226)

property

type: MDC_TIME_SYNC_ACCURACY: unknown code (ISO 11073-10101 Health informatics - Point-of-care#68221)

value: 120000000 (UCUM#us)


 

 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.