This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
ANDThermometer
{ "resourceType" : "Device", "id" : "ANDThermometer", "identifier" : [{ "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "SYSID", "display" : "System Identifier" }] }, "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680", "value" : "54-4A-16-FF-FE-32-12-26" }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers", "code" : "BTMAC", "display" : "Bluetooth Address" }] }, "system" : "http://hl7.org/fhir/sid/eui-48", "value" : "54-4A-16-32-12-26" }], "udiCarrier" : [{ "deviceIdentifier" : "92677176693286", "issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di", "jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi", "carrierHRF" : "(01)92677176693286(21)5160800011", "entryType" : "unknown" }], "manufacturer" : "A&D Medical", "serialNumber" : "5160800011", "name" : [{ "value" : "A&D_UT201BLEA_321226", "type" : { "coding" : [{ "system" : "http://hl7.org/fhir/device-nametype", "code" : "user-friendly-name" }] } }], "modelNumber" : "UT-201BLE-A", "type" : [{ "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "65573", "display" : "MDC_MOC_VMS_MDS_SIMP" }], "text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" }], "deviceVersion" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "531976" }], "text" : "MDC_ID_PROD_SPEC_FW: Firmware revision" }, "value" : "HTP009_137" }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "531975" }], "text" : "MDC_ID_PROD_SPEC_SW: Software revision" }, "value" : "0.00" }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "531974" }], "text" : "MDC_ID_PROD_SPEC_HW: Hardware revision" }, "value" : "0.00" }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532352" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" }, "value" : "4.1" }], "conformsTo" : [{ "specification" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "528392" }], "text" : "MDC_DEV_SPEC_PROFILE_TEMP: Thermometer" }, "version" : "1" }], "property" : [{ "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532353" }], "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN", "code" : "32776" }] } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "532354.0", "display" : "regulation-status" }] }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "N" }], "text" : "Device is Regulated" } }, { "type" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "68220" }], "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" }, "valueCodeableConcept" : { "coding" : [{ "system" : "urn:iso:std:iso:11073:10101", "code" : "532224" }], "text" : "MDC_TIME_SYNC_NONE: No time synchronization" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.0", "display" : "mds-time-capab-real-time-clock" }] }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "real time clock supported" } }, { "type" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7", "code" : "68219.1", "display" : "mds-time-capab-set-clock" }] }, "valueCodeableConcept" : { "coding" : [{ "system" : "http://terminology.hl7.org/CodeSystem/v2-0136", "code" : "Y" }], "text" : "setting the time supported" } }] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Thu, Dec 12, 2024 19:28+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change