"resourceType" : "Device",
"id" : "Nonin20601PulseOx",
"identifier" : [{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID",
"display" : "System Identifier"
}]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "00-1C-05-04-00-00-78-25"
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC",
"display" : "Bluetooth Address"
}]
},
"system" : "http://hl7.org/fhir/sid/eui-48",
"value" : "00-1C-05-00-78-25"
}],
"udiCarrier" : [{
"deviceIdentifier" : "120343001125",
"issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di",
"jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi",
"carrierHRF" : "(01)120343001125(21)0400007825",
"entryType" : "unknown"
}],
"manufacturer" : "Nonin Medical, Inc.",
"serialNumber" : "0400007825",
"name" : [{
"value" : "Nonin_Medical_Inc._323552",
"type" : {
"coding" : [{
"system" : "http://hl7.org/fhir/device-nametype",
"code" : "user-friendly-name"
}]
}
}],
"modelNumber" : "Model 3150",
"type" : [{
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573",
"display" : "MDC_MOC_VMS_MDS_SIMP"
}],
"text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device"
}],
"deviceVersion" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976"
}],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value" : "0.9C"
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "1.0"
}],
"conformsTo" : [{
"specification" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528388"
}],
"text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
},
"version" : "1"
}],
"property" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN",
"code" : "4"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "532354.0"
}],
"text" : "regulation-status"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "N"
}],
"text" : "Device is Regulated"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224"
}],
"text" : "MDC_TIME_SYNC_NONE: No time synchronization"
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "68219.0"
}],
"text" : "mds-time-capab-real-time-clock"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "real time clock supported"
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "68219.2"
}],
"text" : "mds-time-capab-set-clock"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "setting the time supported"
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "68219.2"
}],
"text" : "mds-time-capab-relative-time"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "relative time supported"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68222"
}],
"text" : "MDC_TIME_RES_ABS: Resolution of absolute time clock"
},
"valueQuantity" : {
"value" : 1000000,
"system" : "http://unitsofmeasure.org",
"code" : "us"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68222"
}],
"text" : "MDC_TIME_RES_REL: Resolution of relative time clock"
},
"valueQuantity" : {
"value" : 1000000,
"system" : "http://unitsofmeasure.org",
"code" : "us"
}
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.