This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
Orders and Observations Work Group | Maturity Level: N | Normative (from v4.0.0) | Use Context: Country: World |
Official URL: http://hl7.org/fhir/observation-status
|
Version: 6.0.0-ballot2 | |||
active as of 2021-01-04 | Computable Name: ObservationStatus | |||
Flags: CaseSensitive, Complete. All codes ValueSet: Observation Status | OID: 2.16.840.1.113883.4.642.4.401 |
This Code system is used in the following value sets:
Codes providing the status of an observation.
Generated Narrative: CodeSystem observation-status
Last updated: 2024-11-19T06:04:13.34Z
Profile: Shareable CodeSystem
This case-sensitive code system http://hl7.org/fhir/observation-status
defines the following codes in a Is-A hierarchy:
Lvl | Code | Display | Definition | Copy |
1 | registered | Registered | The existence of the observation is registered, but there is no result yet available. |
|
1 | specimen-in-process | Specimen-in-Process | The specimen being processed in the laboratory but no results are available yet. |
|
1 | preliminary | Preliminary | This is an initial or interim observation: data may be incomplete or unverified. |
|
1 | final | Final | The observation is complete and there are no further actions needed. Additional information such "released", "signed", etc. would be represented using Provenance which provides not only the act but also the actors and dates and other related data. These act states would be associated with an observation status of |
|
1 | amended | Amended | Subsequent to being Final, the observation has been modified. This includes updates/new information and corrections. |
|
2 | corrected | Corrected | Subsequent to being Final, the observation has been modified to correct an error in the original test result(s). |
|
2 | appended | Appended | Subsequent to being Final, the observation has been modified to include additional information, with no changes to the original test result(s). |
|
1 | cancelled | Cancelled | The observation is unavailable because the measurement was not started or not completed (also sometimes called "aborted"). |
|
1 | entered-in-error | Entered in Error | The observation has been withdrawn following previous final release. This electronic record should never have existed, though it is possible that real-world decisions were based on it. (If real-world activity has occurred, the status should be "cancelled" rather than "entered-in-error".). |
|
1 | unknown | Unknown | The authoring/source system does not know which of the status values currently applies for this observation. Note: This concept is not to be used for "other" - one of the listed statuses is presumed to apply, but the authoring/source system does not know which. |
|
1 | cannot-be-obtained | Cannot be obtained | The observation cannot be obtained. |
See the full registry of code systems defined as part of FHIR.
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. See Code System for further information. |
Source | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract') |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |