This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
FHIR Infrastructure Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Read Common TestScript Example (id = "testscript-example-readcommon")
<?xml version="1.0" encoding="UTF-8"?> <TestScript xmlns="http://hl7.org/fhir"> <id value="testscript-example-readcommon"/> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="fhir"/> </extension> <url value="http://hl7.org/fhir/TestScript/testscript-example-readcommon"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.12.8"/> </identifier> <version value="1.0"/> <name value="TestScript Example Read Common"/> <status value="draft"/> <experimental value="true"/> <date value="2024-04-24"/> <publisher value="HL7 International / FHIR Infrastructure"/> <contact> <telecom> <system value="url"/> <value value="http://www.hl7.org/Special/committees/fiwg"/> </telecom> </contact> <description value="TestScript example resource showing the use of the common element to reuse actions within the test element. Each test will perform a Patient read operation utilizing user defined dynamic variables that will hold the Patient resource id values."/> <jurisdiction> <coding> <system value="urn:iso:std:iso:3166"/> <code value="US"/> <display value="United States of America"/> </coding> </jurisdiction> <purpose value="Patient Read Operation"/> <copyright value="© HL7.org 2011+"/> <scope> <artifact value="http://hl7.org/fhir/StructureDefinition/Patient"/> <conformance> <coding> <system value="http://hl7.org/fhir/testscript-scope-conformance-codes"/> <code value="optional"/> </coding> </conformance> <phase> <coding> <system value="http://hl7.org/fhir/testscript-scope-phase-codes"/> <code value="unit"/> </coding> </phase> </scope> <profile value="http://hl7.org/fhir/StructureDefinition/Patient"> <id value="patient-profile"/> </profile> <variable> <name value="PatientResourceId1"/> <defaultValue value="f001"/> </variable> <variable> <name value="PatientResourceId2"/> <defaultValue value="f002"/> </variable> <test id="PatientRead1"> <name value="Patient Read Test 1"/> <description value="Read a known Patient (default id 'f001') and validate response using common action asserts."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Read the known Patient resource on the destination test system using the user defined dynamic variable ${PatientResourceId1}."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/${PatientResourceId1}"/> </operation> </action> <action> <common> <keyRef value="CommonReadActionAsserts"/> </common> </action> </test> <test id="PatientRead2"> <name value="Patient Read Test 2"/> <description value="Read a known Patient (default id 'f002') and validate response using common action asserts."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Read the known Patient resource on the destination test system using the user defined dynamic variable ${PatientResourceId2}."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/${PatientResourceId2}"/> </operation> </action> <action> <common> <keyRef value="CommonReadActionAsserts"/> </common> </action> </test> <common> <key value="CommonReadActionAsserts"/> <name value="Common Read Action Asserts"/> <description value="The common action asserts to evaluate and validate conformance to the base FHIR read operation."/> <action> <assert> <description value="Confirm that the returned HTTP status is 200(OK)."/> <response value="okay"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned format is XML."/> <contentType value="xml"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned HTTP Header Last-Modified is present. Warning only as the server might not support versioning."/> <headerField value="Last-Modified"/> <operator value="notEmpty"/> <stopTestOnFail value="false"/> <warningOnly value="true"/> </assert> </action> <action> <assert> <description value="Confirm that the returned resource type is Patient."/> <resource value="Patient"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned Patient conforms to the base FHIR specification."/> <stopTestOnFail value="false"/> <validateProfileId value="patient-profile"/> <warningOnly value="false"/> </assert> </action> </common> </TestScript>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Wed, Nov 20, 2024 20:05+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change