This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Group, Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
IV Pump Flow Rate (Device) (id = "example-observation-device-flowratemetric")
<?xml version="1.0" encoding="UTF-8"?> <Bundle xmlns="http://hl7.org/fhir"> <id value="example-observation-device-flowratemetric"/> <type value="collection"/> <entry> <fullUrl value="http://hl7.org/fhir/Observation/example-observation-device-flowratemetric"/> <resource> <Observation> <id value="example-observation-device-flowratemetric"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b> Generated Narrative: Observation example-observation-device-flowratemetric</b> </p> <a name="example-observation-device-flowratemetric"> </a> <a name="hcexample-observation-device-flowratemetric"> </a> <p> <b> identifier</b> : <code> http://goodcare.org/observation/id</code> /1191144-10</p> <p> <b> status</b> : Final</p> <p> <b> code</b> : <span title="Codes:{http://loinc.org 8977-1}">Fluid intake intravascular 8 hour</span> </p> <p> <b> subject</b> : <a href="broken-link.html">Device/example-IV-pump</a> </p> <p> <b> focus</b> : <a href="broken-link.html">DeviceMetric/example-iv-pump-flowratemetric</a> </p> <p> <b> effective</b> : 2024-12-05T09:30:10+01:00</p> <p> <b> value</b> : 150 milliliter per 8 hour<span style="background: LightGoldenRodYellow"> (Details: UCUM codemL/(8.h) = 'mL/(8.h)')</span> </p> <p> <b> device</b> : <a href="broken-link.html">Device/example-IV-pump</a> </p> </div> </text> <identifier> <system value="http://goodcare.org/observation/id"/> <value value="1191144-10"/> </identifier> <status value="final"/> <code> <coding> <system value="http://loinc.org"/> <code value="8977-1"/> <display value="Fluid intake intravascular 8 hour"/> </coding> </code> <subject> <reference value="Device/example-IV-pump"/> </subject> <focus> <reference value="DeviceMetric/example-iv-pump-flowratemetric"/> </focus> <effectiveDateTime value="2024-12-05T09:30:10+01:00"/> <valueQuantity> <value value="150"/> <unit value="milliliter per 8 hour"/> <system value="http://unitsofmeasure.org"/> <code value="mL/(8.h)"/> </valueQuantity> <device> <reference value="Device/example-IV-pump"/> </device> </Observation> </resource> </entry> <entry> <fullUrl value="http://hl7.org/fhir/DeviceAssociation/example-device-patient-association"/> <resource> <DeviceAssociation> <id value="example-device-patient-association"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b> Generated Narrative: DeviceAssociation example-device-patient-association</b> </p> <a name="example-device-patient-association"> </a> <a name="hcexample-device-patient-association"> </a> <p> <b> device</b> : <a href="broken-link.html">Device/example-IV-pump</a> </p> <p> <b> status</b> : <span title="Codes:{http://hl7.org/fhir/deviceassociation-status attached}">Attached</span> </p> <p> <b> subject</b> : <a href="patient-example-a.html">Donald Duck</a> </p> </div> </text> <device> <reference value="Device/example-IV-pump"/> </device> <status> <coding> <system value="http://hl7.org/fhir/deviceassociation-status"/> <code value="attached"/> </coding> </status> <subject> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> </DeviceAssociation> </resource> </entry> <entry> <fullUrl value="http://hl7.org/fhir/DeviceMetric/example-iv-pump-flowratemetric"/> <resource> <DeviceMetric> <id value="example-iv-pump-flowratemetric"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b> Generated Narrative: DeviceMetric example-iv-pump-flowratemetric</b> </p> <a name="example-iv-pump-flowratemetric"> </a> <a name="hcexample-iv-pump-flowratemetric"> </a> <p> <b> type</b> : <span title="Codes:{urn:iso:std:iso:11073:10101 157784}">MDC_FLOW_FLUID_PUMP</span> </p> <p> <b> unit</b> : <span title="Codes:{http://unitsofmeasure.org mL/(8.h)}">mL/(8.h)</span> </p> <p> <b> device</b> : <a href="broken-link.html">Device/example-IV-pump</a> </p> <p> <b> category</b> : <span title="Codes:{http://hl7.org/fhir/metric-category measurement}">Measurement</span> </p> </div> </text> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="157784"/> <display value="MDC_FLOW_FLUID_PUMP"/> </coding> </type> <unit> <coding> <system value="http://unitsofmeasure.org"/> <code value="mL/(8.h)"/> <display value="mL/(8.h)"/> </coding> </unit> <device> <reference value="Device/example-IV-pump"/> </device> <category> <coding> <system value="http://hl7.org/fhir/metric-category"/> <code value="measurement"/> <display value="Measurement"/> </coding> </category> </DeviceMetric> </resource> </entry> </Bundle>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot3 generated on Thu, Aug 28, 2025 21:15+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change