This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
Imaging Integration Work Group | Maturity Level: 4 | Trial Use | Compartments: Patient |
Dependency Graph for ImagingStudy FMM level 4
Name | Card. | Type | Dependency Analysis |
---|---|---|---|
ImagingStudy | DomainResource | ||
identifier | 0..* | Identifier | |
status | 1..1 | code | |
modality | 0..* | CodeableConcept | Binding Error: Non THO value set 'http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html' doesn't have FMM and standards-status |
subject | 1..1 | Reference(Patient | Device | Group) | Type Warning: (Device = FMM2-Trial Use vs. Element = FMM4-Trial Use) Type Warning: (Group = FMM3-Trial Use vs. Element = FMM4-Trial Use) |
encounter | 0..1 | Reference(Encounter) | |
started | 0..1 | dateTime | |
basedOn | 0..* | Reference(CarePlan | ServiceRequest | Appointment | AppointmentResponse | Task) | Type Warning: (CarePlan = FMM2-Trial Use vs. Element = FMM4-Trial Use) Type Warning: (Appointment = FMM3-Trial Use vs. Element = FMM4-Trial Use) Type Warning: (AppointmentResponse = FMM3-Trial Use vs. Element = FMM4-Trial Use) Type Warning: (Task = FMM3-Trial Use vs. Element = FMM4-Trial Use) |
partOf | 0..* | Reference(Procedure) | |
referrer | 0..1 | Reference(Practitioner | PractitionerRole) | |
endpoint | 0..* | Reference(Endpoint) | Type Warning: (Endpoint = FMM2-Trial Use vs. Element = FMM4-Trial Use) |
numberOfSeries | 0..1 | unsignedInt | |
numberOfInstances | 0..1 | unsignedInt | |
procedure | 0..* | CodeableReference | Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use) |
location | 0..1 | Reference(Location) | |
reason | 0..* | CodeableReference | Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use) |
note | 0..* | Annotation | |
description | 0..1 | string | |
series | 0..* | BackboneElement | |
uid | 1..1 | id | |
number | 0..1 | unsignedInt | |
modality | 1..1 | CodeableConcept | Binding Error: Non THO value set 'http://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html' doesn't have FMM and standards-status |
description | 0..1 | string | |
numberOfInstances | 0..1 | unsignedInt | |
endpoint | 0..* | Reference(Endpoint) | Type Warning: (Endpoint = FMM2-Trial Use vs. Element = FMM4-Trial Use) |
bodySite | 0..1 | CodeableReference | Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use) |
laterality | 0..1 | CodeableConcept | |
specimen | 0..* | Reference(Specimen) | Type Warning: (Specimen = FMM2-Trial Use vs. Element = FMM4-Trial Use) |
started | 0..1 | dateTime | |
performer | 0..* | BackboneElement | |
function | 0..1 | CodeableConcept | |
actor | 1..1 | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | Device | RelatedPerson | HealthcareService) | Type Warning: (CareTeam = FMM2-Trial Use vs. Element = FMM4-Trial Use) Type Warning: (Device = FMM2-Trial Use vs. Element = FMM4-Trial Use) |
instance | 0..* | BackboneElement | |
uid | 1..1 | id | |
sopClass | 1..1 | oid | |
number | 0..1 | unsignedInt | |
title | 0..1 | string |