Orders and Observations icon Work GroupMaturity Level: 4 Trial Use Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Dependency Graph for ServiceRequest FMM level 4

NameCard.TypeDependency Analysis
.. ServiceRequest DomainResource
... identifier 0..* Identifier
... instantiatesCanonical 0..* canonical(ActivityDefinition | PlanDefinition)
... instantiatesUri 0..* uri
... basedOn 0..* Reference(CarePlan | ServiceRequest | MedicationRequest | RequestOrchestration) Type Warning: (CarePlan = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... replaces 0..* Reference(ServiceRequest)
... requisition 0..1 Identifier
... status 1..1 code
... intent 1..1 code
... category 0..* CodeableConcept
... priority 0..1 code
... doNotPerform 0..1 boolean
... code 0..1 CodeableReference Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use)
... orderDetail 0..* BackboneElement
.... parameterFocus 0..1 CodeableReference Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use)
.... parameter 1..* BackboneElement
..... code 1..1 CodeableConcept
..... value[x] 1..1
...... valueQuantity Quantity
...... valueRatio Ratio
...... valueRange Range
...... valueBoolean boolean
...... valueCodeableConcept CodeableConcept
...... valueString string
...... valuePeriod Period
... quantity[x] 0..1
.... quantityQuantity Quantity
.... quantityRatio Ratio
.... quantityRange Range
... subject 1..1 Reference(Patient | Group | Location | Device) Type Warning: (Group = FMM3-Trial Use vs. Element = FMM4-Trial Use)
Type Warning: (Device = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... focus 0..* Reference(Any) Type Warning: (Any = FMM1-Trial Use vs. Element = FMM4-Trial Use)
... encounter 0..1 Reference(Encounter)
... occurrence[x] 0..1
.... occurrenceDateTime dateTime
.... occurrencePeriod Period
.... occurrenceTiming Timing
... asNeeded[x] 0..1
.... asNeededBoolean boolean
.... asNeededCodeableConcept CodeableConcept
... authoredOn 0..1 dateTime
... requester 0..1 Reference(Practitioner | PractitionerRole | Organization | Patient | RelatedPerson | Device) Type Warning: (Device = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... performerType 0..1 CodeableConcept
... performer 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | HealthcareService | Patient | Device | RelatedPerson) Type Warning: (CareTeam = FMM2-Trial Use vs. Element = FMM4-Trial Use)
Type Warning: (Device = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... location 0..* CodeableReference Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use)
... reason 0..* CodeableReference Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use)
... insurance 0..* Reference(Coverage | ClaimResponse) Type Warning: (ClaimResponse = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... supportingInfo 0..* CodeableReference Type Error: (CodeableReference = FMM5-Draft vs. Element = FMM4-Trial Use)
... specimen 0..* Reference(Specimen) Type Warning: (Specimen = FMM2-Trial Use vs. Element = FMM4-Trial Use)
... bodySite 0..* CodeableConcept
... bodyStructure 0..1 Reference(BodyStructure) Type Warning: (BodyStructure = FMM1-Trial Use vs. Element = FMM4-Trial Use)
... note 0..* Annotation
... patientInstruction 0..* BackboneElement
.... instruction[x] 0..1
..... instructionMarkdown markdown
..... instructionReference Reference(DocumentReference
... relevantHistory 0..* Reference(Provenance)