This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions
FHIR Infrastructure Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Read TestScript Example (id = "testscript-example-readtest")
<?xml version="1.0" encoding="UTF-8"?> <TestScript xmlns="http://hl7.org/fhir"> <id value="testscript-example-readtest"/> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"> <valueCode value="fhir"/> </extension> <url value="http://hl7.org/fhir/TestScript/testscript-example-readtest"/> <identifier> <system value="urn:ietf:rfc:3986"/> <value value="urn:oid:2.16.840.1.113883.4.642.12.2"/> </identifier> <version value="1.0"/> <name value="TestScript Example Read Test"/> <status value="draft"/> <experimental value="true"/> <date value="2017-01-18"/> <publisher value="HL7 International / FHIR Infrastructure"/> <contact> <telecom> <system value="url"/> <value value="http://www.hl7.org/Special/committees/fiwg"/> </telecom> </contact> <description value="TestScript example resource with ported Sprinkler basic read tests R001, R002, R003, R004. The read tests will utilize user defined dynamic variables that will hold the Patient resource id values."/> <jurisdiction> <coding> <system value="urn:iso:std:iso:3166"/> <code value="US"/> <display value="United States of America"/> </coding> </jurisdiction> <purpose value="Patient Read Operation"/> <copyright value="© HL7.org 2011+"/> <metadata> <link> <url value="http://hl7.org/fhir/patient.html"/> <description value="Demographics and other administrative information about an individual or animal receiving care or other health-related services."/> </link> <capability> <required value="true"/> <validated value="false"/> <description value="Patient Read Operation"/> <link value="http://hl7.org/fhir/http.html#read"/> <capabilities value="http://hl7.org/fhir/CapabilityStatement/example"/> </capability> </metadata> <scope> <artifact value="http://hl7.org/fhir/StructureDefinition/Patient"/> <conformance> <coding> <system value="http://hl7.org/fhir/testscript-scope-conformance-codes"/> <code value="optional"/> </coding> </conformance> <phase> <coding> <system value="http://hl7.org/fhir/testscript-scope-phase-codes"/> <code value="unit"/> </coding> </phase> </scope> <profile value="http://hl7.org/fhir/StructureDefinition/Patient"> <id value="patient-profile"/> </profile> <variable> <name value="KnownPatientResourceId"/> <defaultValue value="example"/> </variable> <variable> <name value="NonExistsPatientResourceId"/> <defaultValue value="does-not-exist"/> </variable> <test id="R001"> <name value="Sprinkler Read Test R001"/> <description value="Read a known Patient and validate response."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Read the known Patient resource on the destination test system using the user defined dynamic variable ${KnownPatientResourceId}."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/${KnownPatientResourceId}"/> </operation> </action> <action> <assert> <description value="Confirm that the returned HTTP status is 200(OK)."/> <response value="okay"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned format is XML."/> <contentType value="xml"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned HTTP Header Last-Modified is present. Warning only as the server might not support versioning."/> <headerField value="Last-Modified"/> <operator value="notEmpty"/> <stopTestOnFail value="false"/> <warningOnly value="true"/> </assert> </action> <action> <assert> <description value="Confirm that the returned resource type is Patient."/> <resource value="Patient"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> <action> <assert> <description value="Confirm that the returned Patient conforms to the base FHIR specification."/> <stopTestOnFail value="false"/> <validateProfileId value="patient-profile"/> <warningOnly value="false"/> </assert> </action> </test> <test id="R002"> <name value="Sprinkler Read Test R002"/> <description value="Read an unknown Resource Type and validate response."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Attempt to read the Parameters resource type. What we really want here is an illegal type but the build process won't allow that. Parameters is a valid resource which doesn't have an end-point so, this should fail."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/1"/> </operation> </action> <action> <assert> <description value="Confirm that the returned HTTP status is 404(Not Found)."/> <response value="notFound"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> </test> <test id="R003"> <name value="Sprinkler Read Test R003"/> <description value="Read a known, non-existing Patient and validate response."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Attempt to read the non-existing Patient resource on the destination test system using the user defined dynamic variable ${NonExistsPatientResourceId}."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/${NonExistsPatientResourceId}"/> </operation> </action> <action> <assert> <description value="Confirm that the returned HTTP status is 404(Not Found)."/> <response value="notFound"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> </test> <test id="R004"> <name value="Sprinkler Read Test R004"/> <description value="Read a Patient using a known bad formatted resource id and validate response."/> <action> <operation> <type> <system value="http://hl7.org/fhir/restful-interaction"/> <code value="read"/> </type> <resource value="Patient"/> <description value="Attempt to read a Patient resource on the destination test system using known bad formatted resource id."/> <accept value="xml"/> <encodeRequestUrl value="true"/> <params value="/ID-may-not-contain-CAPITALS"/> </operation> </action> <action> <assert> <description value="Confirm that the returned HTTP status is 400(Bad Request)."/> <response value="badRequest"/> <stopTestOnFail value="false"/> <warningOnly value="false"/> </assert> </action> </test> </TestScript>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Fri, Nov 22, 2024 16:30+0000.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change