FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions icon

4.3.2.173 CodeSystem http://hl7.org/fhir/issue-type

FHIR Infrastructure icon Work Group  Maturity Level: N Normative (from v4.0.0) Use Context: Country: World
Official URL: http://hl7.org/fhir/issue-type Version: 6.0.0-ballot2
active as of 2021-01-04 Computable Name: IssueType
Flags: CaseSensitive, Complete. All codes ValueSet: Issue Type OID: 2.16.840.1.113883.4.642.4.411

This Code system is used in the following value sets:

  • ValueSet: Issue Type (A code that describes the type of issue.)

A code that describes the type of issue.

Generated Narrative: CodeSystem issue-type

Last updated: 2024-11-22T16:22:46.427Z

Profile: Shareable CodeSystem

This case-sensitive code system http://hl7.org/fhir/issue-type defines the following codes in a Is-A hierarchy:

LvlCodeDisplayDefinitionCopy
1 invalid Invalid Content Content invalid against the specification or a profile. btn btn
2   structure Structural Issue A structural issue in the content such as wrong namespace, unable to parse the content completely, invalid syntax, etc. btn btn
2   required Required element missing A required element is missing. btn btn
2   value Element value invalid An element or header value is invalid. btn btn
2   invariant Validation rule failed A content validation rule failed - e.g. a schematron rule. btn btn
1 security Security Problem An authentication/authorization/permissions issue of some kind. btn btn
2   login Login Required The client needs to initiate an authentication process. btn btn
2   unknown Unknown User The user or system was not able to be authenticated (either there is no process, or the proferred token is unacceptable). btn btn
2   expired Session Expired User session expired; a login may be required. btn btn
2   forbidden Forbidden The user does not have the rights to perform this action. btn btn
2   suppressed Information Suppressed Some information was not or might not have been returned due to business rules, consent or privacy rules, or access permission constraints. This information may be accessible through alternate processes. btn btn
1 processing Processing Failure Processing issues. These are expected to be final e.g. there is no point resubmitting the same content unchanged. btn btn
2   not-supported Content not supported The interaction, operation, resource or profile is not supported. btn btn
2   duplicate Duplicate An attempt was made to create a duplicate record. btn btn
2   multiple-matches Multiple Matches Multiple matching records were found when the operation required only one match. btn btn
2   not-found Not Found The reference provided was not found. In a pure RESTful environment, this would be an HTTP 404 error, but this code may be used where the content is not found further into the application architecture. btn btn
3     deleted Deleted The reference pointed to content (usually a resource) that has been deleted. btn btn
2   too-long Content Too Long Provided content is too long (typically, this is a denial of service protection type of error). btn btn
2   code-invalid Invalid Code The code or system could not be understood, or it was not valid in the context of a particular ValueSet.code. btn btn
2   extension Unacceptable Extension An extension was found that was not acceptable, could not be resolved, or a modifierExtension was not recognized. btn btn
2   too-costly Operation Too Costly The operation was stopped to protect server resources; e.g. a request for a value set expansion on all of SNOMED CT. btn btn
2   business-rule Business Rule Violation The content/operation failed to pass some business rule and so could not proceed. btn btn
2   conflict Edit Version Conflict Content could not be accepted because of an edit conflict (i.e. version aware updates). (In a pure RESTful environment, this would be an HTTP 409 error, but this code may be used where the conflict is discovered further into the application architecture.). btn btn
2   limited-filter Limited Filter Application Some search filters might not have applied on all results. Data may have been included that does not meet all of the filters listed in the `self` `Bundle.link`. btn btn
1 transient Transient Issue Transient processing issues. The system receiving the message may be able to resubmit the same content once an underlying issue is resolved. btn btn
2   lock-error Lock Error A resource/record locking failure (usually in an underlying database). btn btn
2   no-store No Store Available The persistent store is unavailable; e.g. the database is down for maintenance or similar action, and the interaction or operation cannot be processed. btn btn
2   exception Exception An unexpected internal error has occurred. btn btn
2   timeout Timeout An internal timeout has occurred. btn btn
2   incomplete Incomplete Results Not all data sources typically accessed could be reached or responded in time, so the returned information might not be complete (applies to search interactions and some operations). btn btn
2   throttled Throttled The system is not prepared to handle this request due to load management. btn btn
1 informational Informational Note A message unrelated to the processing success of the completed operation (examples of the latter include things like reminders of password expiry, system maintenance times, etc.). btn btn
1 success Operation Successful The operation completed successfully. btn btn

 

See the full registry of code systems defined as part of FHIR.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. See Code System for further information.
Source The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code