FHIR CI-Build

This is the Continuous Integration Build of FHIR (will be incorrect/inconsistent at times).
See the Directory of published versions

Example ValueSet/device-type (XML)

Responsible Owner: Terminology Infrastructure Work GroupStandards Status: Informative

Raw XML (canonical form + also see XML Format Specification)

Definition for Value SetDevice Type

<?xml version="1.0" encoding="UTF-8"?>

<ValueSet xmlns="http://hl7.org/fhir">
  <id value="device-type"/> 
  <meta> 
    <lastUpdated value="2025-11-27T16:48:47.349+00:00"/> 
  </meta> 
  <text> 
    <status value="generated"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p class="res-header-id">
        <b> Generated Narrative: ValueSet device-type</b> 
      </p> 
      <a name="device-type"> </a> 
      <a name="hcdevice-type"> </a> 
      <p> This value set includes codes based on the following rules:</p> 
      <ul> 
        <li> Include these codes as defined in 
          <code> urn:iso:std:iso:11073:10101</code> 
          <span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span> 
          <table class="none">
            <tr> 
              <td style="white-space:nowrap">
                <b> Code</b> 
              </td> 
              <td> 
                <b> Display</b> 
              </td> 
            </tr> 
            <tr> 
              <td> 528391</td> 
              <td> Blood Pressure Cuff</td> 
            </tr> 
            <tr> 
              <td> 528404</td> 
              <td> Body Composition Analyzer</td> 
            </tr> 
            <tr> 
              <td> 528425</td> 
              <td> Cardiovascular Device</td> 
            </tr> 
            <tr> 
              <td> 528402</td> 
              <td> Coagulation meter</td> 
            </tr> 
            <tr> 
              <td> 528409</td> 
              <td> Continuous Glucose Monitor</td> 
            </tr> 
            <tr> 
              <td> 528390</td> 
              <td> Electro cardiograph</td> 
            </tr> 
            <tr> 
              <td> 528457</td> 
              <td> Generic 20601 Device</td> 
            </tr> 
            <tr> 
              <td> 528401</td> 
              <td> Glucose Monitor</td> 
            </tr> 
            <tr> 
              <td> 528455</td> 
              <td> Independent Activity/Living Hub</td> 
            </tr> 
            <tr> 
              <td> 528403</td> 
              <td> Insulin Pump</td> 
            </tr> 
            <tr> 
              <td> 528405</td> 
              <td> Peak Flow meter</td> 
            </tr> 
            <tr> 
              <td> 528388</td> 
              <td> Pulse Oximeter</td> 
            </tr> 
            <tr> 
              <td> 528397</td> 
              <td> Respiration rate</td> 
            </tr> 
            <tr> 
              <td> 528408</td> 
              <td> Sleep Apnea Breathing Equipment</td> 
            </tr> 
            <tr> 
              <td> 528426</td> 
              <td> Strength Equipment</td> 
            </tr> 
            <tr> 
              <td> 528392</td> 
              <td> Thermometer</td> 
            </tr> 
            <tr> 
              <td> 528399</td> 
              <td> Weight Scale</td> 
            </tr> 
          </table> 
        </li> 
        <li> Include codes from
          <a href="http://www.snomed.org/">
            <code> http://snomed.info/sct</code> 
          </a> 
          <span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span>  where concept  is-a 49062001 (Device)
        </li> 
        <li> Include codes from
          <a href="http://www.snomed.org/">
            <code> http://snomed.info/sct</code> 
          </a> 
          <span title="Version is not explicity stated. No matching Code System found"> version Not Stated (use latest from terminology server)</span>  where concept  is-a 706689003 (Application programme software)
        </li> 
      </ul> 
    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="oo"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="informative"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="1"/> 
  </extension> 
  <url value="http://hl7.org/fhir/ValueSet/device-type"/> 
  <identifier> 
    <system value="urn:ietf:rfc:3986"/> 
    <value value="urn:oid:2.16.840.1.113883.4.642.3.1376"/> 
  </identifier> 
  <version value="6.0.0-ballot3"/> 
  <name value="DeviceType"/> 
  <title value="Device Type"/> 
  <status value="active"/> 
  <experimental value="false"/> 
  <publisher value="HL7 Orders and Observations Workgroup"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://hl7.org/fhir"/> 
    </telecom> 
  </contact> 
  <description value="Codes used to identify medical devices. Includes concepts from SNOMED CT (http://www.snomed.o
  rg/) where concept is-a 49062001 (Device)  and is provided as a suggestive example."/> 
  <jurisdiction> 
    <coding> 
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/> 
      <code value="001"/> 
      <display value="World"/> 
    </coding> 
  </jurisdiction> 
  <copyright value="This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is
   copyright of the International Health Terminology Standards Development Organisation
   (IHTSDO). Implementers of these specifications must have the appropriate SNOMED
   CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snome
  d-ct or info@snomed.org"/> 
  <compose> 
    <include> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <concept> 
        <code value="528391"/> 
        <display value="Blood Pressure Cuff"/> 
      </concept> 
      <concept> 
        <code value="528404"/> 
        <display value="Body Composition Analyzer"/> 
      </concept> 
      <concept> 
        <code value="528425"/> 
        <display value="Cardiovascular Device"/> 
      </concept> 
      <concept> 
        <code value="528402"/> 
        <display value="Coagulation meter"/> 
      </concept> 
      <concept> 
        <code value="528409"/> 
        <display value="Continuous Glucose Monitor"/> 
      </concept> 
      <concept> 
        <code value="528390"/> 
        <display value="Electro cardiograph"/> 
      </concept> 
      <concept> 
        <code value="528457"/> 
        <display value="Generic 20601 Device"/> 
      </concept> 
      <concept> 
        <code value="528401"/> 
        <display value="Glucose Monitor"/> 
      </concept> 
      <concept> 
        <code value="528455"/> 
        <display value="Independent Activity/Living Hub"/> 
      </concept> 
      <concept> 
        <code value="528403"/> 
        <display value="Insulin Pump"/> 
      </concept> 
      <concept> 
        <code value="528405"/> 
        <display value="Peak Flow meter"/> 
      </concept> 
      <concept> 
        <code value="528388"/> 
        <display value="Pulse Oximeter"/> 
      </concept> 
      <concept> 
        <code value="528397"/> 
        <display value="Respiration rate"/> 
      </concept> 
      <concept> 
        <code value="528408"/> 
        <display value="Sleep Apnea Breathing Equipment"/> 
      </concept> 
      <concept> 
        <code value="528426"/> 
        <display value="Strength Equipment"/> 
      </concept> 
      <concept> 
        <code value="528392"/> 
        <display value="Thermometer"/> 
      </concept> 
      <concept> 
        <code value="528399"/> 
        <display value="Weight Scale"/> 
      </concept> 
    </include> 
    <include> 
      <system value="http://snomed.info/sct"/> 
      <filter> 
        <property value="concept"/> 
        <op value="is-a"/> 
        <value value="49062001"/> 
      </filter> 
    </include> 
    <include> 
      <system value="http://snomed.info/sct"/> 
      <filter> 
        <property value="concept"/> 
        <op value="is-a"/> 
        <value value="706689003"/> 
      </filter> 
    </include> 
  </compose> 
</ValueSet> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.