CH LAB-Order (R4)
3.0.0-ci-build - ci-build
CH LAB-Order (R4), published by HL7 Switzerland. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/hl7ch/ch-lab-order/ and changes regularly. See the Directory of published versions
{
"resourceType" : "SpecimenDefinition",
"id" : "serum-venous-new",
"meta" : {
"profile" : [
🔗 "http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-specimendefinition-r4"
]
},
"text" : {
"status" : "extensions",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: SpecimenDefinition serum-venous-new</b></p><a name=\"serum-venous-new\"> </a><a name=\"hcserum-venous-new\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-ch-lab-specimendefinition-r4.html\">CH LAB Specimen Definition (R4)</a></p></div><p><b>CH LAB-Order SpecimenDefinition.status (R5 backport)</b>: active</p><p><b>CH LAB SpecimenDefinition Testing Destination</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v2-0074 CH}\">Chemistry</span></p><p><b>CH LAB Specimen Collection Method</b>: <span title=\"Codes:{http://snomed.info/sct 28520004}\">Venipuncture for blood test (procedure)</span></p><p><b>typeCollected</b>: <span title=\"Codes:{http://snomed.info/sct 122555007}\">Venous blood specimen</span></p><h3>TypeTesteds</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Extension</b></td><td><b>Type</b></td><td><b>Preference</b></td></tr><tr><td style=\"display: none\">*</td><td/><td><span title=\"Codes:{http://snomed.info/sct 119364003}\">Serum specimen</span></td><td>Preferred</td></tr></table></div>"
},
"extension" : [
{
"url" : "http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-specimen-status",
"valueCode" : "active"
},
{
"url" : "http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-specimen-definition-testing-destination",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0074",
"code" : "CH",
"display" : "Chemistry"
}
]
}
},
{
"url" : "http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-specimen-collection-method",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "28520004",
"display" : "Venipuncture for blood test (procedure)"
}
]
}
}
],
"typeCollected" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "122555007",
"display" : "Venous blood specimen"
}
]
},
"typeTested" : [
{
"extension" : [
{
"extension" : [
{
"url" : "temperatureQualifier",
"valueCodeableConcept" : {
"coding" : [
{
"system" : "http://fhir.ch/ig/ch-lab-order/CodeSystem/ch-lab-cs-specimen-container-temperature",
"code" : "ambient",
"display" : "Ambient"
}
]
}
},
{
"url" : "maxDuration",
"valueDuration" : {
"value" : 2,
"system" : "http://unitsofmeasure.org",
"code" : "h"
}
},
{
"url" : "instruction",
"valueMarkdown" : "Keep at room temperature; centrifuge within 2 hours after collection."
}
],
"url" : "http://fhir.ch/ig/ch-lab-order/StructureDefinition/ch-lab-specimen-handling"
}
],
"type" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "119364003",
"display" : "Serum specimen"
}
]
},
"preference" : "preferred"
}
]
}