eHealth Infrastructure
8.0.0 - release Denmark flag

eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 8.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions

: Execute patient devices - XML Representation

Active as of 2026-01-14

Raw xml | Download


<OperationDefinition xmlns="http://hl7.org/fhir">
  <id value="-s-execute-patient-devices"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: OperationDefinition -s-execute-patient-devices</b></p><a name="-s-execute-patient-devices"> </a><a name="hc-s-execute-patient-devices"> </a><p>URL: [base]/$execute-patient-devices</p><h3>Parameters</h3><table class="grid"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Scope</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>anonymization</td><td/><td>1..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#string">string</a></td><td/><td><div><p>This parameter is used to control if the report should be anonymized or not. If the value is set to NONE (no anonymization) and the user lacks the required permission, an exception is thrown.</p>
</div></td></tr><tr><td>IN</td><td>organization</td><td/><td>0..1</td><td><a href="http://hl7.org/fhir/R4/references.html#Reference">Reference</a></td><td/><td><div><p>organization: Filter on EpisodeOfCare.managingOrganization match.</p>
</div></td></tr><tr><td>IN</td><td>period</td><td/><td>0..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#Period">Period</a></td><td/><td><div><p>period: Filter on DeviceUseStatement.whenUsed overlap.</p>
</div></td></tr><tr><td>IN</td><td>devicetype</td><td/><td>0..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#Coding">Coding</a></td><td/><td><div><p>The kind or type of device.</p>
</div></td></tr><tr><td>OUT</td><td>return</td><td/><td>0..1</td><td><a href="http://hl7.org/fhir/R4/binary.html">Binary</a></td><td/><td/></tr></table></div>
  </text>
  <url
       value="http://ehealth.sundhed.dk/fhir/OperationDefinition/-s-execute-patient-devices"/>
  <version value="8.0.0"/>
  <name value="execute-patient-devices"/>
  <title value="Execute patient devices"/>
  <status value="active"/>
  <kind value="operation"/>
  <date value="2026-01-14T09:08:08+00:00"/>
  <publisher
             value="Den telemedicinske infrastruktur (eHealth Infrastructure)"/>
  <contact>
    <name value="Den telemedicinske infrastruktur (eHealth Infrastructure)"/>
    <telecom>
      <system value="url"/>
      <value value="http://ehealth.sundhed.dk"/>
    </telecom>
  </contact>
  <description
               value="### Report Contents
This report contains Device information for each EpisodeOfCare:
- Device
- DeviceUseStatement
- DeviceMetrics
### Grouping 
This report is grouped by EpsiodeOfCare. Each group is returned in a separate JSon file.
### Parameters
- organization: Filter on EpisodeOfCare.managingOrganization match
- period: Filter on DeviceUseStatement.whenUsed overlap
### Output
Output can be found in Binary.content. This is a Base64 encoded .zip file containing JSon files corresponding to the report groups.
### Example output
All returned objects are Fhir resources. See the implementation guide for details

    {
        'EHealthEpisodeOfCare': {
            'resourceType': 'EpisodeOfCare',
            'id': 'F417C17F9FDE24C9090BD629C8EE1697',
            'meta': {
                'versionId': '1',
                'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare']
            },
            'extension': [{
                    'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-episodeofcare-caremanagerOrganization',
                    'valueReference': {
                        'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/313D8B0E0AC8EA8169D1DA45ECEEACB9'
                    }
                }
            ],
            'status': 'active',
            'diagnosis': [{
                    'condition': {
                        'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/Condition/9A7FCD55CA3031585A8F1690DB1D8034'
                    },
                    'rank': 1
                }
            ],
            'patient': {
                'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/A1D94F323D8EF09E5D913D9522FD83C4'
            },
            'managingOrganization': {
                'reference': 'https://organization.local.ehealth.sundhed.dk/fhir/Organization/8DC75F2B12BCC832F92CC065C3D0B451'
            },
            'period': {
                'start': '1970-01-01T01:00:01+01:00',
                'end': '1970-01-01T01:01:40+01:00'
            }
        },
        'EHealthDeviceUseStatement': [{
                'resourceType': 'DeviceUseStatement',
                'id': '9541E8EAEAD24376F208D5CD8A4D25F5',
                'meta': {
                    'versionId': '1',
                    'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement']
                },
                'extension': [{
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-deviceusestatement-context',
                        'valueReference': {
                            'reference': 'https://careplan.local.ehealth.sundhed.dk/fhir/CarePlan/23D34B29DD02EB232B6575537FE8ADC5'
                        }
                    }
                ],
                'status': 'active',
                'subject': {
                    'reference': 'https://patient.local.ehealth.sundhed.dk/fhir/Patient/AC38B1F6391F256002E5A7BE69CB2586'
                },
                'device': {
                    'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'
                }
            }
        ],
        'EHealthDevice': [{
                'resourceType': 'Device',
                'id': '08D51B81A7FE5B480278150A94D4048A',
                'meta': {
                    'versionId': '1',
                    'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device']
                },
                'extension': [{
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-device-privatelyOwned',
                        'valueBoolean': true
                    }
                ],
                'status': 'active'
            }
        ],
        'EHealthDeviceMetric': [{
                'resourceType': 'DeviceMetric',
                'id': '7EA21ACD27EE012439F1440574A6BB21',
                'meta': {
                    'versionId': '1',
                    'profile': ['http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric']
                },
                'extension': [{
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-qualities',
                        'extension': [{
                                'url': 'category',
                                'valueCodeableConcept': {
                                    'coding': [{
                                            'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                            'code': 'initial'
                                        }
                                    ]
                                }
                            }, {
                                'url': 'value',
                                'valueInteger': 5
                            }
                        ]
                    }, {
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                        'extension': [{
                                'url': 'category',
                                'valueCodeableConcept': {
                                    'coding': [{
                                            'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                            'code': 'initial'
                                        }
                                    ]
                                }
                            }, {
                                'url': 'value',
                                'valueInteger': 10
                            }
                        ]
                    }, {
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                        'extension': [{
                                'url': 'category',
                                'valueCodeableConcept': {
                                    'coding': [{
                                            'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                            'code': 'initial'
                                        }
                                    ]
                                }
                            }, {
                                'url': 'value',
                                'valueInteger': 12
                            }
                        ]
                    }, {
                        'url': 'http://ehealth.sundhed.dk/fhir/StructureDefinition/ehealth-devicemetric-templateQualities',
                        'extension': [{
                                'url': 'category',
                                'valueCodeableConcept': {
                                    'coding': [{
                                            'system': 'http://ehealth.sundhed.dk/cs/devicemetric-quality-types',
                                            'code': 'initial'
                                        }
                                    ]
                                }
                            }, {
                                'url': 'value',
                                'valueInteger': 14
                            }
                        ]
                    }
                ],
                'identifier': {
                    'value': 'Foo'
                },
                'type': {
                    'text': 'code'
                },
                'source': {
                    'reference': 'https://device.local.ehealth.sundhed.dk/fhir/Device/08D51B81A7FE5B480278150A94D4048A'
                },
                'category': 'calculation'
            }
        ]
    }
"/>
  <jurisdiction>
    <coding>
      <system value="urn:iso:std:iso:3166"/>
      <code value="DK"/>
      <display value="Denmark"/>
    </coding>
  </jurisdiction>
  <affectsState value="true"/>
  <code value="execute-patient-devices"/>
  <system value="true"/>
  <type value="false"/>
  <instance value="false"/>
  <parameter>
    <name value="anonymization"/>
    <use value="in"/>
    <min value="1"/>
    <max value="1"/>
    <documentation
                   value="This parameter is used to control if the report should be anonymized or not. If the value is set to NONE (no anonymization) and the user lacks the required permission, an exception is thrown."/>
    <type value="string"/>
  </parameter>
  <parameter>
    <name value="organization"/>
    <use value="in"/>
    <min value="0"/>
    <max value="1"/>
    <documentation
                   value="organization: Filter on EpisodeOfCare.managingOrganization match."/>
    <type value="Reference"/>
  </parameter>
  <parameter>
    <name value="period"/>
    <use value="in"/>
    <min value="0"/>
    <max value="1"/>
    <documentation
                   value="period: Filter on DeviceUseStatement.whenUsed overlap."/>
    <type value="Period"/>
  </parameter>
  <parameter>
    <name value="devicetype"/>
    <use value="in"/>
    <min value="0"/>
    <max value="1"/>
    <documentation value="The kind or type of device."/>
    <type value="Coding"/>
  </parameter>
  <parameter>
    <name value="return"/>
    <use value="out"/>
    <min value="0"/>
    <max value="1"/>
    <type value="Binary"/>
  </parameter>
</OperationDefinition>