eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 5.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions
| Official URL: http://ehealth.sundhed.dk/vs/situation-quality | Version: 5.0.0 | |||
| Active as of 2019-02-13 | Computable Name: SituationQuality | |||
Value set of hierarchical codes stating the quality of a measurement situation.
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
http://ehealth.sundhed.dk/cs/situation-quality
Expansion performed internally based on codesystem Situation Quality v5.0.0 (CodeSystem)
This value set contains 15 concepts
| Level | Code | System | Display | Definition |
| 1 | none | http://ehealth.sundhed.dk/cs/situation-quality | No quality needed | Quality value where no derivation rule logic nor values are expected |
| 2 | unknown | http://ehealth.sundhed.dk/cs/situation-quality | Unknown quality | Unknown quality (Unlikely to be adequate if a quality value is expected) |
| 3 | derivation-error | http://ehealth.sundhed.dk/cs/situation-quality | Error in deriving or determining the quality | Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error |
| 4 | normal | http://ehealth.sundhed.dk/cs/situation-quality | Normal/neutral situation quality | Normal/neutral situation quality |
| 5 | finger-not-cold | http://ehealth.sundhed.dk/cs/situation-quality | Finger is not cold | Finger is not cold |
| 5 | supported-by-armrest | http://ehealth.sundhed.dk/cs/situation-quality | Performed with armrest support | Performed with armrest support |
| 5 | arms-crossed | http://ehealth.sundhed.dk/cs/situation-quality | Performed with arms crossed | Performed with arms crossed |
| 5 | lying-down | http://ehealth.sundhed.dk/cs/situation-quality | Performed lying down | Performed lying down |
| 5 | sitting | http://ehealth.sundhed.dk/cs/situation-quality | Performed sitting | Performed sitting |
| 1 | Unknown | http://ehealth.sundhed.dk/cs/situation-quality | Unknown quality | Unknown quality (Unlikely to be adequate if a quality value is expected) |
| 2 | None | http://ehealth.sundhed.dk/cs/situation-quality | No quality needed | Quality value where no derivation rule logic nor values are expected |
| 3 | DerivationError | http://ehealth.sundhed.dk/cs/situation-quality | Error in deriving or determining the quality | Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error |
| 4 | SQ1 | http://ehealth.sundhed.dk/cs/situation-quality | Situation quality 1 (example) | Example, needs further clarification. |
| 5 | SQ2 | http://ehealth.sundhed.dk/cs/situation-quality | Situation quality 2 (example) | Example, needs further clarification. |
| 6 | SQ3 | http://ehealth.sundhed.dk/cs/situation-quality | Situation quality 3 (example) | Example, needs further clarification. |
Explanation of the columns that may appear on this page:
| Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
| System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
| Code | The code (used as the code in the resource instance) |
| Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
| Definition | An explanation of the meaning of the concept |
| Comments | Additional notes about how to use the code |