eHealth Infrastructure
3.5.1 - release Denmark flag

eHealth Infrastructure, published by Den telemedicinske infrastruktur (eHealth Infrastructure). This guide is not an authorized publication; it is the continuous build for version 3.5.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/fut-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions

ValueSet: Situation Quality (Experimental)

Official URL: http://ehealth.sundhed.dk/vs/situation-quality Version: 3.5.1
Active as of 2019-02-13 Computable Name: SituationQuality

Value set of hierarchical codes stating the quality of a measurement situation.

References

This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Logical Definition (CLD)

 

Expansion

Expansion performed internally based on codesystem Situation Quality v3.5.1 (CodeSystem)

This value set contains 15 concepts

LevelCodeSystemDisplay (da-DK)Definition
1  nonehttp://ehealth.sundhed.dk/cs/situation-qualityIngen situationskvalitet krævet/ventetQuality value where no derivation rule logic nor values are expected
2    unknownhttp://ehealth.sundhed.dk/cs/situation-qualityUkendt situationskvalitetUnknown quality (Unlikely to be adequate if a quality value is expected)
3      derivation-errorhttp://ehealth.sundhed.dk/cs/situation-qualitySituationskvaliteten kunne ikke bestemmes grundet manglende input, utilgængelig logik, eller anden fejl.Quality value could not be derived due to insufficient input, unknown/unavailable logic, or other error
4        normalhttp://ehealth.sundhed.dk/cs/situation-qualityNormalt/neutralt situationskvalitetsniveauNormal/neutral situation quality
5          finger-not-coldhttp://ehealth.sundhed.dk/cs/situation-qualityFinger ej koldFinger is not cold
5          supported-by-armresthttp://ehealth.sundhed.dk/cs/situation-qualityUdført med støtte fra armlænPerformed with armrest support
5          arms-crossedhttp://ehealth.sundhed.dk/cs/situation-qualityudført med korslagte armePerformed with arms crossed
5          lying-downhttp://ehealth.sundhed.dk/cs/situation-qualityUdført liggendePerformed lying down
5          sittinghttp://ehealth.sundhed.dk/cs/situation-qualityUdført siddendePerformed sitting
1  Unknownhttp://ehealth.sundhed.dk/cs/situation-qualityUnknown quality (Unlikely to be adequate if a quality value is expected)
2    Nonehttp://ehealth.sundhed.dk/cs/situation-qualityQuality value where no derivation rule logic nor values are expected
3      DerivationErrorhttp://ehealth.sundhed.dk/cs/situation-qualityQuality value could not be derived due to insufficient input, unknown/unavailable logic, or other error
4        SQ1http://ehealth.sundhed.dk/cs/situation-qualityExample, needs further clarification.
5          SQ2http://ehealth.sundhed.dk/cs/situation-qualityExample, needs further clarification.
6            SQ3http://ehealth.sundhed.dk/cs/situation-qualityExample, needs further clarification.

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code