CH ELM (R4), published by Federal Office of Public Health FOPH. This guide is not an authorized publication; it is the continuous build for version 1.7.0-ci-build built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/ahdis/ch-elm/ and changes regularly. See the Directory of published versions

CodeSystem: CH ELM FOPH Business Rules

Official URL: http://fhir.ch/ig/ch-elm/CodeSystem/ch-elm-foph-business-rules Version: 1.7.0-ci-build
Active as of 2024-11-15 Computable Name: ChElmFophBusinessRules

Copyright/Legal: CC0-1.0

This CH ELM code system describes specific business rules of the FOPH, which are applied during processing. Please note that the set of rules detailed herein only covers processes explicitly declared by the FOPH. Additional rules, not included in this code system, are applied by the FHIR validation logic, resulting in further codes. For more information about these additional codes, consult the official FHIR documentation and the implementation guideline.

This Code system is referenced in the content logical definition of the following value sets:

  • This CodeSystem is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)

Generated Narrative: CodeSystem ch-elm-foph-business-rules

This case-insensitive code system http://fhir.ch/ig/ch-elm/CodeSystem/ch-elm-foph-business-rules defines the following codes in a Is-A hierarchy:

LvlCodeDisplayDefinition
1 information Information A purely informational message.
2   FOPH-000 Generic Information
1 warning Warning If the rule is violated, the resource is conformant, but it is not necessarily following best practice.
2   FOPH-014 The patient address state element should contain a two letter canton code.
2   FOPH-005 The required anonymization for the reported organism was violated. The following field(s) are affected: %fields%
2   FOPH-011 The material is already specified by the leading code. The additional material specified in specimen.type will be ignored.
2   FOPH-010 Attention, the code %code% (%codeSystem%) expires on %validTo%. Please adjust your systems by this date.
2   FOPH-015 For VCT patients, the identifier (OASI/AHV/ID-N) must not be reported.
2   FOPH-001 Generic Warning
2   FOPH-006 The following elements for the patient's address are expected: %missingElements%.
1 error Error If the rule is violated, the resource is not conformant.
2   FOPH-009 The transmitted code %code% (%codeSystem%) is outside the defined validity period %validFrom% - %validTo%.
2   FOPH-016 The country code specified under patient address could not resolved. An ISO 3166 2 or 3 letter code is expected.
2   FOPH-002 Generic Error
2   FOPH-007 The specified material is not supported by the provided leading code.
2   FOPH-012 The transmitted leading code %code% (%codeSystem%) could not be found in the current value set.
2   FOPH-008 The specified organism is not supported by the provided leading code.
2   FOPH-004 The provided laboratory identification "%identifier%" is either unknown or corresponds to a laboratory for which your account does not have reporting permissions. Please verify your laboratory identification. If it's correct, complete the necessary onboarding process before submitting data on behalf of this lab.
2   FOPH-013 The transmitted code %code% (%codeSystem%) is outside the defined validity period.