KIP Infrastructure
2.12.0 - ci-build
KIP Infrastructure, published by Sundhedsvæsenets Kvalitetsinstitut with Trifork Digital Health A/S. This guide is not an authorized publication; it is the continuous build for version 2.12.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/KIP-infrastructure/implementation-guide/ and changes regularly. See the Directory of published versions
Active as of 2022-06-27 |
<ValueSet xmlns="http://hl7.org/fhir">
<id value="NIHSS5FunktionArm"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet NIHSS5FunktionArm</b></p><a name="NIHSS5FunktionArm"> </a><a name="hcNIHSS5FunktionArm"> </a><ul><li>Include these codes as defined in <a href="CodeSystem-NIHSS5MotorArm.html"><code>https://kip.rkkp.dk/fhir/CodeSystem/NIHSS5MotorArm</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-0">0</a></td><td>0 = Ingen nedsynkning</td><td>No drift; limb holds 90 (or 45) degrees for full 10 seconds.</td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-1">1</a></td><td>1 = Nedsynkning, men ikke til underlag</td><td>Drift; limb holds 90 (or 45) degrees, but drifts down before full 10 seconds; does not hit bed or other support.</td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-2">2</a></td><td>2 = Nogen kraft mod tyngde</td><td>Some effort against gravity; limb cannot get to or maintain (if cued) 90 (or 45) degrees, drifts down to bed, but has some effort against gravity.</td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-3">3</a></td><td>3 = Falder til underlag</td><td>No effort against gravity; limb falls.</td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-4">4</a></td><td>4 = Ingen bevægelse</td><td>No movement.</td></tr><tr><td><a href="CodeSystem-NIHSS5MotorArm.html#NIHSS5MotorArm-UN">UN</a></td><td>5 = Kan ikke testes (amputation/stivgjort led/andet)</td><td>Amputation or joint fusion, explain:</td></tr></table></li></ul></div>
</text>
<url value="https://kip.rkkp.dk/fhir/ValueSet/NIHSS5FunktionArm"/>
<version value="2.12.0"/>
<name value="NIHSS5FunktionArm"/>
<title value="NIHSS - 5. Motorisk funktion i arm"/>
<status value="active"/>
<experimental value="true"/>
<date value="2022-06-27T00:00:00+02:00"/>
<publisher
value="Sundhedsvæsenets Kvalitetsinstitut with Trifork Digital Health A/S"/>
<contact>
<name
value="Sundhedsvæsenets Kvalitetsinstitut with Trifork Digital Health A/S"/>
<telecom>
<system value="url"/>
<value value="https://trifork.com"/>
</telecom>
<telecom>
<system value="email"/>
<value value="rbk@trifork.com"/>
</telecom>
</contact>
<description
value="The National Institute of Health Stroke Scale (NIHSS) - 5. Motorisk funktion i arm"/>
<compose>
<include>
<system value="https://kip.rkkp.dk/fhir/CodeSystem/NIHSS5MotorArm"/>
<concept>
<code value="0"/>
<display value="0 = Ingen nedsynkning"/>
</concept>
<concept>
<code value="1"/>
<display value="1 = Nedsynkning, men ikke til underlag"/>
</concept>
<concept>
<code value="2"/>
<display value="2 = Nogen kraft mod tyngde"/>
</concept>
<concept>
<code value="3"/>
<display value="3 = Falder til underlag"/>
</concept>
<concept>
<code value="4"/>
<display value="4 = Ingen bevægelse"/>
</concept>
<concept>
<code value="UN"/>
<display
value="5 = Kan ikke testes (amputation/stivgjort led/andet)"/>
</concept>
</include>
</compose>
</ValueSet>