Point-of-Care Device Implementation Guide
0.4.0 - CI Build International flag

Point-of-Care Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 0.4.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/uv-pocd/ and changes regularly. See the Directory of published versions

: ECG Sample Array metric example - XML Representation

Page standards status: Informative

Raw xml | Download


<DeviceMetric xmlns="http://hl7.org/fhir">
  <id value="ECGSampleArrayDeviceMetric"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/pocd/StructureDefinition/SampleArrayDeviceMetric"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: DeviceMetric ECGSampleArrayDeviceMetric</b></p><a name="ECGSampleArrayDeviceMetric"> </a><a name="hcECGSampleArrayDeviceMetric"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-SampleArrayDeviceMetric.html">Sample Array DeviceMetric profile</a></p></div><p><b>Resolution extension</b>: 0.001</p><p><b>Sweep Speed extension</b>: 25 mm/s<span style="background: LightGoldenRodYellow"> (Details: UCUM  codemm/s = 'mm/s')</span></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 131328}">ECG</span></p><p><b>unit</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 266418}">mV</span></p><p><b>source</b>: <a href="Device-PhysioMonitorMdsDevice.html">Device: extension = United States of America (the),-&gt;Practitioner Alice B. Careful ,8760,156,Dmo; identifier = urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680#01-23-45-67-89-AB-CD-EF; status = active; manufacturer = MyCompany; serialNumber = 123456; modelNumber = PM1; type = MDC_DEV_MON_PHYSIO_MULTI_PARAM_MDS</a></p><p><b>parent</b>: <a href="Device-ECGChannelDevice.html">Device: status = active; type = MDC_DEV_ECG_CHAN</a></p><p><b>operationalStatus</b>: On</p><p><b>color</b>: Color Green</p><p><b>category</b>: Measurement</p></div>
  </text>
  <extension
             url="http://hl7.org/fhir/uv/pocd/StructureDefinition/resolution">
    <valueDecimal value="0.001"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/uv/pocd/StructureDefinition/sweep-speed">
    <valueQuantity>
      <value value="25"/>
      <unit value="mm/s"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="mm/s"/>
    </valueQuantity>
  </extension>
  <type>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="131328"/>
      <display value="MDC_ECG_ELEC_POTL"/>
    </coding>
    <text value="ECG"/>
  </type>
  <unit>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="266418"/>
      <display value="MDC_DIM_MILLI_VOLT"/>
    </coding>
    <text value="mV"/>
  </unit>
  <source>🔗 
    <reference value="Device/PhysioMonitorMdsDevice"/>
  </source>
  <parent>🔗 
    <reference value="Device/ECGChannelDevice"/>
  </parent>
  <operationalStatus value="on"/>
  <color value="green"/>
  <category value="measurement"/>
</DeviceMetric>