Point-of-Care Device Implementation Guide
0.4.0 - CI Build International flag

Point-of-Care Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 0.4.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/uv-pocd/ and changes regularly. See the Directory of published versions

: NBP VMD example - XML Representation

Page standards status: Informative

Raw xml | Download


<Device xmlns="http://hl7.org/fhir">
  <id value="NBPVmdDevice"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/pocd/StructureDefinition/VmdDevice"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Device NBPVmdDevice</b></p><a name="NBPVmdDevice"> </a><a name="hcNBPVmdDevice"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-VmdDevice.html">VMD Device profile</a></p></div><h3>UdiCarriers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>DeviceIdentifier</b></td><td><b>CarrierHRF</b></td></tr><tr><td style="display: none">*</td><td>00012345678912</td><td>(01)00012345678912(21)567890</td></tr></table><p><b>status</b>: Active</p><p><b>manufacturer</b>: MyCompany</p><p><b>serialNumber</b>: 567890</p><p><b>partNumber</b>: 1122-3344</p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 70686}">MDC_DEV_PRESS_BLD_NONINV_VMD</span></p><p><b>parent</b>: <a href="Device-PhysioMonitorMdsDevice.html">Device: extension = ,-&gt;Practitioner Alice B. Careful ,8760,156,Dmo; identifier = urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680#01-23-45-67-89-AB-CD-EF; status = active; manufacturer = MyCompany; serialNumber = 123456; modelNumber = PM1; type = MDC_DEV_MON_PHYSIO_MULTI_PARAM_MDS</a></p></div>
  </text>
  <udiCarrier>
    <deviceIdentifier value="00012345678912"/>
    <carrierHRF value="(01)00012345678912(21)567890"/>
  </udiCarrier>
  <status value="active"/>
  <manufacturer value="MyCompany"/>
  <serialNumber value="567890"/>
  <partNumber value="1122-3344"/>
  <type>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="70686"/>
      <display value="MDC_DEV_PRESS_BLD_NONINV_VMD"/>
    </coding>
  </type>
  <parent>🔗 
    <reference value="Device/PhysioMonitorMdsDevice"/>
  </parent>
</Device>