Personal Health Device Implementation Guide
1.0.0 - STU 1 International flag

Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

ValueSet: ASN1measurement

Official URL: http://hl7.org/fhir/uv/phd/ValueSet/ASN1measurement Version: 1.0.0
Draft as of 2018-09-17 Computable Name: ASN1measurement

ValueSet for the ANS1ToHL7 codes that are derived from enumeration measurements.

References

Logical Definition (CLD)

 

Expansion

Expansion based on codesystem ASN1 bits to HL7 enumerated values v1.0.0 (CodeSystem)

This value set contains 104 concepts.

LevelCodeSystemDisplayDefinition
1  67846.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-alert-off

Indicates both the high and the low limit alerts are disabled

1  67846.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-low-off

Indicates the low limit alert is disabled

1  67846.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-high-off

Indicates the high limit alert is disabled

1  150604.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-disconnected

Indicates the device is not connected with the sensor

1  150604.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

Indicates the sensor has malfunctioned

1  150604.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-displaced

Indicates the sensor is not correctly placed on the user

1  150604.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-unsupported

Indicates the sensor connected to the device is unsupported

1  150604.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-off

Indicates the sensor is not connected to the user

1  150604.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-interference

Indicates the sensor is experiencing interference

1  150604.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-searching

Indicates the sensor is searching for a signal

1  150604.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-pulse-questionable

Indicates a questionable pulse has been detected

1  150604.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-non-pulsatile

Indicates a non pulsatile signal has been detected

1  150604.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-erratic

Indicates a signal has been discovered, but it is erratic

1  150604.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-low-perfusion

Indicates the signal is experiencing low perfusion

1  150604.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-poor

Indicates the signal has been discovered, but it is poor

1  150604.12http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-inadequate

Indicates the signal has been discovered, but it is inadequate

1  150604.13http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-processing-irregularity

Indicates the signal has been discovered, but is experiencing processing irregularity

1  150604.14http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-equipment-malfunction

Indicates a device malfunction has occurred

1  150604.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-extended-update

Indicates an extended display update is in progress on device

1  150605.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-nominal

Indicates no abnormalities have been detected by the sensor

1  150605.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-marginal

Indicates the pulse profusion or quality is marginal

1  150605.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-minimal

Indicates the pulse profusion or quality is minimal

1  150605.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-unacceptable

Indicates the pulse profusion or quality is unacceptable

1  8410584.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss

Loss of unspecified lead wire or electrode connection

1  8410584.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss

Loss of unspecified lead signal

1  8410584.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-first-lead

Loss of 1st lead wire or electrode connection

1  8410584.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-first-lead

Loss of 1st lead signal

1  8410584.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-second-lead

Loss of 2nd lead wire or electrode connection

1  8410584.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-second-lead

Loss of 2nd lead signal

1  8410584.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-third-lead

Loss of 3rd lead wire or electrode connection

1  8410584.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-third-lead

Loss of 3rd lead signal

1  8417752.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-battery-low

The device battery is low

1  8417752.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

The sensor has malfunctioned

1  8417752.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-sample-size-insufficient

The sensor's sample size is insufficient

1  8417752.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-strip-insertion

The test strip was inserted incorrectly

1  8417752.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-strip-type-incorrect

The test strip type is incompatable with the sensor

1  8417752.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-high

The value reported by the sensor is too high

1  8417752.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-low

The value reported by the sensor is too low

1  8417752.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-high

The temperature is too high

1  8417752.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-low

The temperature is too low

1  8417752.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-read-interrupt

The read process was interrupted

1  8417752.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-gen-fault

General Device Fault

1  8417752.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-out-of-range

The temperature is out of range

1  8417909.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-device-battery-low

The INR device battery is low

1  8417909.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-malfunction

The INR device sensor has malfunctioned

1  8417909.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-sample-size-insufficient

The sample size was insufficient

1  8417909.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-strip-insertion

The test script was inserted incorrectly

1  8417909.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-strip-type-incorrect

The test strip used is not compatible with the INR

1  8417909.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-result-too-high

The test result is too high

1  8417909.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-result-too-low

The test result is too low

1  8417909.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-temp-too-high

The temperature is too high

1  8417909.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-temp-too-low

The temperature is too low

1  8417909.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-read-interrupt

The read process was interrupted

1  8417909.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-device-gen-fault

General device fault

1  8417909.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-calibration-due

The INR sensor calibration is due

1  8408608.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-undetermined

Undetermined device status event

1  8408608.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-reset

Device reset

1  8408608.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error

Device error

1  8408608.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-mechanical

Mechanical error

1  8408608.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-electronic

Electronic error

1  8408608.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-software

Software error

1  8408608.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-battery

Battery error

1  8408608.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service

Undetermined device status event, service needed

1  8408608.16http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-time-sync-required

Time sync service required

1  8408608.17http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-calibration-required

Calibration required

1  8408608.18http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-replenishment-required

Replenishment required

1  8408608.25http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-low

Battery power is too low

1  8408608.26http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-depleted

Battery is depleted

1  8408608.27http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-replaced

Battery has been replaced

1  8408608.28http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-interrupted

Battery was interrupted

1  8418060.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-session-stopped

Session stopped

1  8418060.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-type-incorrect

Sensor type incorrect for device

1  8418060.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

The sensor malfunctioned

1  8418060.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-specific-alert

Device specific alert

1  8418060.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-not-allowed

Calibrating the sensor is not allowed

1  8418060.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-recommended

Calibrating the sensor is recommended

1  8418060.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-required

Calibrating the sensor is required

1  8418060.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-high

Temperature is too high for a valid result

1  8418060.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-low

Temperature is too low for a valid result

1  8418060.12http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-below-patient-low

Sensor result below the Patient Low level

1  8418060.13http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-above-patient-high

Sensor result above the Patient High level

1  8418060.14http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-low-hypo

Sensor result below level

1  8418060.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-high-hyper

Sensor result above level

1  8418060.16http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-rate-decrease-exceeded

The sensor rate of decrease has been exceeded

1  8418060.17http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-rate-increase-exceeded

The sensor rate of increase has been exceeded

1  8418060.18http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-low

Sensor result is lower than the device can process

1  8418060.19http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-high

Sensor result is higher than the device can process

1  8418060.20http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-com-out-of-range

The sensor communication is out of range

1  8418512.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-status-Undetermined

the status of the battery is unknown

1  8418512.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-absent

Indicates if the battery is absent

1  8418512.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-active

Indicates if the battery is active in the system

1  8418512.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-charging

Indicates if the battery is charging

1  8418512.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-fullyCharged

Indicates if the battery is fully charged

1  8418512.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-disposable

Indicates if the battery is disposable

1  8418512.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-rechargeable

Indicates if battery is rechargable

1  8418512.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-faulty

Indicates if battery is faulty

2    8418512.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-overTemperature

Indicates if the battery is too hot

1  8418512.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-incompatible

Indicates if battery is incompatible

1  8410608.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7body-movement

Indicates too much body movement

1  8410608.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7cuff-too-loose

Indicates the cuff was too loose

1  8410608.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7irregular-pulse

Indicates an irregular pulse was detected

1  8410608.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-over-range-limit

Indicates the pulse was too high for sensor to work

1  8410608.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-under-range-limit

Indicates the pulse was too low for sensor to work

1  8410608.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7improper-body-position

Indicates the cuff was incorrectly placed with respect to the heart


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code