Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
a fhir:Device ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "phd-00601900010E9234.F45EABA80832"] ; #
fhir:meta [
( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice> ] )
] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"phd-00601900010E9234.F45EABA80832\"> </a><a name=\"hcphd-00601900010E9234.F45EABA80832\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">ResourceDevice "phd-00601900010E9234.F45EABA80832" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-PhdDevice.html\">PhdDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier/00-60-19-00-01-0E-92-34, Bluetooth MAC address/F4-5E-AB-A8-08-32</p><p><b>manufacturer</b>: Diabetes Care</p><p><b>serialNumber</b>: 20130200002A</p><p><b>modelNumber</b>: Gluc-23</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573)</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Monitor <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528401)</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976)</span></p><p><b>value</b>: GLU.7AJ-02</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 3.55.6</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: 5.4.2</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353)</span></p><p><b>valueCode</b>: HDP BT Glucose Monitor certified <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"CodeSystem-ContinuaPHD.html\">Continua Device Interfaces</a>#16401)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.5.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></p></blockquote></div>"
] ; #
fhir:identifier ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SYSID" ] ] ) ] ;
fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
fhir:value [ fhir:v "00-60-19-00-01-0E-92-34" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "BTMAC" ] ] ) ] ;
fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48/bluetooth"^^xsd:anyURI ] ;
fhir:value [ fhir:v "F4-5E-AB-A8-08-32" ]
] ) ; #
fhir:manufacturer [ fhir:v "Diabetes Care"] ; #
fhir:serialNumber [ fhir:v "20130200002A"] ; #
fhir:modelNumber [ fhir:v "Gluc-23"] ; #
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "65573" ] ] ) ;
fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ]
] ; #
fhir:specialization ( [
fhir:systemType [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "528401" ] ] ) ;
fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_GLUCOSE: Glucose Monitor" ] ] ;
fhir:version [ fhir:v "1" ]
] ) ; #
fhir:version ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531976" ] ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_FW: Firmware revision" ] ] ;
fhir:value [ fhir:v "GLU.7AJ-02" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531975" ] ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software revision" ] ] ;
fhir:value [ fhir:v "3.55.6" ]
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531974" ] ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_HW: Hardware revision" ] ] ;
fhir:value [ fhir:v "5.4.2" ]
] ) ; #
fhir:property ( [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532353" ] ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: certified device list as transport-specialization combo" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "16401" ] ] ) ] )
] [
fhir:type [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "68220" ] ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ] ] ;
( fhir:valueCode [
( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532224" ] ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_NONE:" ] ] )
] ) . #
IG © 2016+ HL7 International / Health Care Devices. Package hl7.fhir.uv.phd#1.1.0 based on FHIR 4.0.1. Generated 2024-05-15
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change