Union of http://hl7.org/fhir/us/core/StructureDefinition/us-core-implantable-device and http://hl7.org/fhir/us/nhsn-dqm/StructureDefinition/nhsn-submitting-device

This is the set of resources that conform to either of the profiles US Core Implantable Device Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-implantable-device) and NHSN Submitting Device (http://hl7.org/fhir/us/nhsn-dqm/StructureDefinition/nhsn-submitting-device). E.g. what you have to deal with if you get resources conforming to one of them

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*Item used in healthcare
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... meta Σ0..1MetaMetadata about the resource
ele-1: All FHIR elements must have a @value or children
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... language 0..1codeLanguage of the resource content
Binding: ?? (preferred): A human language.


ele-1: All FHIR elements must have a @value or children
... text 0..1NarrativeText summary of the resource, for human interpretation
ele-1: All FHIR elements must have a @value or children
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier 0..*IdentifierInstance identifier
ele-1: All FHIR elements must have a @value or children
... definition 0..1Reference(DeviceDefinition)The reference to the definition for the device
ele-1: All FHIR elements must have a @value or children
... udiCarrier SΣ0..*BackboneElementUnique Device Identifier (UDI) Barcode string
ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... deviceIdentifier SΣ0..1stringMandatory fixed portion of UDI
ele-1: All FHIR elements must have a @value or children
.... issuer 0..1uriUDI Issuing Organization
ele-1: All FHIR elements must have a @value or children
.... jurisdiction 0..1uriRegional UDI authority
ele-1: All FHIR elements must have a @value or children
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
ele-1: All FHIR elements must have a @value or children
.... carrierHRF SΣ0..1stringUDI Human Readable Barcode String
ele-1: All FHIR elements must have a @value or children
.... entryType 0..1codebarcode | rfid | manual +
Binding: ?? (required): Codes to identify how UDI data was entered.


ele-1: All FHIR elements must have a @value or children
... status ?!Σ0..1codeactive | inactive | entered-in-error | unknown
Binding: ?? (required): The availability status of the device.


ele-1: All FHIR elements must have a @value or children
... statusReason 0..*CodeableConceptonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: ?? (extensible): The availability status reason of the device.


ele-1: All FHIR elements must have a @value or children
... distinctIdentifier S0..1stringThe distinct identification string
ele-1: All FHIR elements must have a @value or children
... manufacturer 0..1stringName of device manufacturer
ele-1: All FHIR elements must have a @value or children
... manufactureDate S0..1dateTimeDate when the device was made
ele-1: All FHIR elements must have a @value or children
... expirationDate S0..1dateTimeDate and time of expiry of this device (if applicable)
ele-1: All FHIR elements must have a @value or children
... lotNumber S0..1stringLot number of manufacture
ele-1: All FHIR elements must have a @value or children
... serialNumber S0..1stringSerial number assigned by the manufacturer
ele-1: All FHIR elements must have a @value or children
... deviceName 0..*BackboneElementThe name of the device as given by the manufacturer
ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... name 1..1stringThe name of the device
ele-1: All FHIR elements must have a @value or children
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: ?? (required): The type of name the device is referred by.


ele-1: All FHIR elements must have a @value or children
... modelNumber 0..1stringThe model number for the device
ele-1: All FHIR elements must have a @value or children
... partNumber 0..1stringThe part number of the device
ele-1: All FHIR elements must have a @value or children
... type S0..1CodeableConceptThe kind or type of device
Binding: ?? (extensible): left: Codes to identify medical devices; right: Codes to identify medical devices.


ele-1: All FHIR elements must have a @value or children
... specialization 0..*BackboneElementThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... systemType 1..1CodeableConceptThe standard that is used to operate and communicate
ele-1: All FHIR elements must have a @value or children
.... version 0..1stringThe version of the standard that is used to operate and communicate
ele-1: All FHIR elements must have a @value or children
... version 0..*BackboneElementThe actual design of the device or software version running on the device
ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... type 0..1CodeableConceptThe type of the device version
ele-1: All FHIR elements must have a @value or children
.... component 0..1IdentifierA single component of the device version
ele-1: All FHIR elements must have a @value or children
.... value 1..1stringThe version text
ele-1: All FHIR elements must have a @value or children
... property 0..*BackboneElementThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
ele-1: All FHIR elements must have a @value or children
.... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
.... type 1..1CodeableConceptCode that specifies the property DeviceDefinitionPropetyCode (Extensible)
ele-1: All FHIR elements must have a @value or children
.... valueQuantity 0..*QuantityProperty value as a quantity
ele-1: All FHIR elements must have a @value or children
.... valueCode 0..*CodeableConceptProperty value as a code, e.g., NTP4 (synced to NTP)
ele-1: All FHIR elements must have a @value or children
... patient S0..1Reference(Patient)Patient to whom Device is affixed
ele-1: All FHIR elements must have a @value or children
... owner 0..1Reference(Organization)Organization responsible for device
ele-1: All FHIR elements must have a @value or children
... contact 0..*ContactPointDetails for human/organization for support
ele-1: All FHIR elements must have a @value or children
... location 0..1Reference(Location)Where the device is found
ele-1: All FHIR elements must have a @value or children
... url 0..1uriNetwork address to contact device
ele-1: All FHIR elements must have a @value or children
... note 0..*AnnotationDevice notes and comments
ele-1: All FHIR elements must have a @value or children
... safety Σ0..*CodeableConceptSafety Characteristics of Device
ele-1: All FHIR elements must have a @value or children
... parent 0..1Reference(Device)The parent device
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format