QI-Core Implementation Guide
6.0.0 - STU6 United States of America flag

QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 6.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/ and changes regularly. See the Directory of published versions

: ServiceNotRequested with value set example - XML Representation

Raw xml | Download



<ServiceRequest xmlns="http://hl7.org/fhir">
  <id value="negation-example"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: ServiceRequest</b><a name="negation-example"> </a><a name="hcnegation-example"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource ServiceRequest &quot;negation-example&quot; </p></div><p><b>QICore Do Not Perform Reason</b>: Procedure discontinued (situation) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#416406003)</span></p><p><b>status</b>: completed</p><p><b>intent</b>: order</p><p><b>category</b>: Surgical Procedure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#387713003)</span></p><p><b>priority</b>: urgent</p><p><b>doNotPerform</b>: true</p><p><b>code</b>: Not Done Value Set: Intermittent pneumatic compression devices (IPC) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (Not done value set: <a href="http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214">http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214</a>)</span></p><p><b>subject</b>: <a href="Patient-example.html">Patient/example</a> &quot; CHALMERS&quot;</p><p><b>encounter</b>: <a href="Encounter-example.html">Encounter/example</a></p><p><b>occurrence</b>: 2013-04-05</p><p><b>authoredOn</b>: 2013-04-04</p><p><b>bodySite</b>: Appendix structure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a>#66754008)</span></p></div>
  </text>
  <extension
             url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-doNotPerformReason">
    <valueCodeableConcept>
      <coding>
        <system value="http://snomed.info/sct"/>
        <code value="416406003"/>
        <display value="Procedure discontinued (situation)"/>
      </coding>
    </valueCodeableConcept>
  </extension>
  <status value="completed"/>
  <intent value="order"/>
  <category>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="387713003"/>
      <display value="Surgical Procedure"/>
    </coding>
  </category>
  <priority value="urgent"/>
  <doNotPerform value="true"/>
  <code>
    <extension
               url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-notDoneValueSet">
      <valueCanonical
                      value="http://cts.nlm.nih.gov/fhir/2.16.840.1.113883.3.117.1.7.1.214"/>
    </extension>
    <text
          value="Not Done Value Set: Intermittent pneumatic compression devices (IPC)"/>
  </code>
  <subject>🔗 
    <reference value="Patient/example"/>
  </subject>
  <encounter>🔗 
    <reference value="Encounter/example"/>
  </encounter>
  <occurrenceDateTime value="2013-04-05"/>
  <authoredOn value="2013-04-04"/>
  <bodySite>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="66754008"/>
      <display value="Appendix structure"/>
    </coding>
  </bodySite>
</ServiceRequest>