Intersection of http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-use-of-device and http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-use-of-device

This is the set of resources that conform to both Personal Functioning and Engagement Use of Device (http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-use-of-device) and Personal Functioning and Engagement Use of Device (http://hl7.org/fhir/us/pacio-pfe/StructureDefinition/pfe-use-of-device).

Structure

NameFlagsCard.TypeDescription & Constraintsdoco
.. DeviceUseStatement 0..*Record of use of a device
dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label
dom-6: A resource should have narrative for robust management
... meta Σ0..1MetaMetadata about the resource
ele-1: All FHIR elements must have a @value or children
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
ele-1: All FHIR elements must have a @value or children
... language 0..1codeLanguage of the resource content
Binding: ?? (preferred): A human language.

Additional BindingsPurpose
??Max Binding

ele-1: All FHIR elements must have a @value or children
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional content defined by implementations
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
... identifier Σ0..*IdentifierExternal identifier for this record
ele-1: All FHIR elements must have a @value or children
... basedOn Σ0..*Reference(ServiceRequest)Fulfills plan, proposal or order
ele-1: All FHIR elements must have a @value or children
... status ?!Σ1..1codeactive | completed | entered-in-error +
Binding: ?? (required): A coded concept indicating the current status of the Device Usage.


ele-1: All FHIR elements must have a @value or children
... subject Σ1..1Reference(US Core Patient Profile)Patient using device
ele-1: All FHIR elements must have a @value or children
... derivedFrom Σ0..*Reference(ServiceRequest | Procedure | Claim | Observation | QuestionnaireResponse | DocumentReference)Supporting information
ele-1: All FHIR elements must have a @value or children
... timing[x] Σ0..1How often the device was used
ele-1: All FHIR elements must have a @value or children
.... timingTimingTiming
.... timingPeriodPeriod
.... timingDateTimedateTime
... recordedOn Σ0..1dateTimeWhen statement was recorded
ele-1: All FHIR elements must have a @value or children
... source Σ0..1Reference(Patient | Practitioner | PractitionerRole | RelatedPerson)Who made the statement
ele-1: All FHIR elements must have a @value or children
... device Σ1..1Reference(Device)The description of the device that the patient used.
ele-1: All FHIR elements must have a @value or children
... reasonCode Σ0..*CodeableConceptWhy device was used
ele-1: All FHIR elements must have a @value or children
... reasonReference Σ0..*Reference(Condition | Observation | DiagnosticReport | DocumentReference | Media)Why was DeviceUseStatement performed?
ele-1: All FHIR elements must have a @value or children
... bodySite Σ0..1CodeableConceptTarget body site
Binding: ?? (example): Codes describing anatomical locations. May include laterality.


ele-1: All FHIR elements must have a @value or children
... note 0..*AnnotationAddition details (comments, instructions)
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format