Order Catalog Implementation Guide
1.0.0-ballot - CI Build International flag

Order Catalog Implementation Guide, published by HL7 International / Orders and Observations. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-order-catalog/ and changes regularly. See the Directory of published versions

PlanDefinition: Lab service Rubella IgM (Experimental)

Official URL: http://hl7.org/fhir/uv/order-catalog/PlanDefinition/example-lab-service-rubella-serum Version: 1.0.0-ballot
Standards status: Informative Computable Name: RubellaIgM
Other Identifiers: OID:2.16.840.1.113883.4.642.40.999.34.9

Usage:Workflow Task: laboratory test order entry task

Rubella IgM quantitative on serum

Additional Narrative:

Laboratory service title: laboratory service - Rubella IgM quantification on serum

id: example-lab-service-rubella-serum

meta - profile: hl7.org/fhir/uv/order-catalog/StructureDefinition/LabServiceDefinition

CatalogReference: Composition/example-lab-compendium-header

name: RubellaIgM

description: Rubella IgM quantitative on serum

type: test

status: draft, experimental

publisher: HL7 International

contact: HL7 Orders and Observations Work Group ( http://www.hl7.org/Special/committees/orders/index.cfm)

useContext (task): LABOE (laboratory test order entry task)

topic: SNOMED CT: 165994006 |Sample serology|

action:
extension:SpecimenRequested: SpecimenDefinition/example-specimen-2ml-serum
code: LOINC: 5335-5 |Rubella virus IgM Ab [Units/volume] in Serum by Immunoassay|
definition: ActivityDefinition/example-lab-procedure-rubella