Order Catalog Implementation Guide, published by HL7 International / Orders and Observations. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-order-catalog/ and changes regularly. See the Directory of published versions
Page standards status: Informative |
Language: en-US
Profile: Device Model
Reference to a catalog: Composition Worldwide Device Catalog
udiDeviceIdentifier
deviceIdentifier: 00075020063816
issuer: urn:oid:2.51.1.1
jurisdiction: urn:oid:2.16.840.1.113883.3.150
MarketDistributions
MarketPeriod SubJurisdiction 2016-09-17 --> (ongoing) urn:oid:2.16.840.1.113883.3.150
manufacturer: Philips Consumer Lifestyle B.V.
Name | Type |
Philips Avent Breast Pump Single | Registered name |
modelNumber: SCF332
classification
type: Breast pump, electric
Justifications
Type Citation Citation A mains electricity (AC-powered) device used to extract milk from the breast, typically for collecting and feeding to an infant. The device produces a continuous low-grade suction through a funnel-like component that is applied to the breast; the milk collects in an attached vessel (e.g., a sterilized bottle). The device may have a safety mechanism to prevent a potentially harmful increase in negative pressure.
classification
type: Electric breast pump
languageCode: English (United States)
property
type: For single use
value: false
property
type: Prescription use
value: false
property
type: Over the counter
value: true
property
type: Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)
value: false
guideline
relatedArtifact
type: Documentation
label: Device described in GUDID:
Documents