International Patient Summary Implementation Guide, published by HL7 International / Patient Care. This guide is not an authorized publication; it is the continuous build for version 1.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-ips/ and changes regularly. See the Directory of published versions

: Observation: urine wbc range example - XML Representation

Page standards status: Informative

Raw xml | Download



<Observation xmlns="http://hl7.org/fhir">
  <id value="urine-wbc-range"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: Observation</b><a name="urine-wbc-range"> </a><a name="hcurine-wbc-range"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation &quot;urine-wbc-range&quot; </p></div><p><b>status</b>: final</p><p><b>category</b>: Laboratory <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-observation-category.html">Observation Category Codes</a>#laboratory)</span></p><p><b>code</b>: Leukocytes [#/area] in Urine sediment by Microscopy high power field <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#5821-4)</span></p><p><b>subject</b>: <a href="Patient-66033.html">Patient/66033</a> &quot; LUX-BRENNARD&quot;</p><p><b>effective</b>: 2018-02-16 09:17:00+0100</p><p><b>performer</b>: <a href="Organization-TII-Organization1.html">Organization/TII-Organization1</a> &quot;Someplace General Hospital&quot;</p><p><b>value</b>: 10-20 per HPF</p><p><b>interpretation</b>: High <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-v3-ObservationInterpretation.html">ObservationInterpretation</a>#H)</span></p><h3>ReferenceRanges</h3><table class="grid"><tr><td style="display: none">-</td><td><b>High</b></td><td><b>Type</b></td></tr><tr><td style="display: none">*</td><td>5 per HPF<span style="background: LightGoldenRodYellow"> (Details: UCUM code /[HPF] = '/[HPF]')</span></td><td>Normal Range <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-referencerange-meaning.html">Observation Reference Range Meaning Codes</a>#normal)</span></td></tr></table></div>
  </text>
  <status value="final"/>
  <category>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/observation-category"/>
      <code value="laboratory"/>
    </coding>
  </category>
  <code>
    <coding>
      <system value="http://loinc.org"/>
      <code value="5821-4"/>
      <display
               value="Leukocytes [#/area] in Urine sediment by Microscopy high power field"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/66033"/>
  </subject>
  <effectiveDateTime value="2018-02-16T09:17:00+01:00"/>
  <performer>🔗 
    <reference value="Organization/TII-Organization1"/>
  </performer>
  <valueRange>
    <low>
      <value value="10"/>
      <unit value="per HPF"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="/[HPF]"/>
    </low>
    <high>
      <value value="20"/>
      <unit value="per HPF"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="/[HPF]"/>
    </high>
  </valueRange>
  <interpretation>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/>
      <code value="H"/>
    </coding>
  </interpretation>
  <referenceRange>
    <high>
      <value value="5"/>
      <unit value="per HPF"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="/[HPF]"/>
    </high>
    <type>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/referencerange-meaning"/>
        <code value="normal"/>
        <display value="Normal Range"/>
      </coding>
    </type>
  </referenceRange>
</Observation>