DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: Example-ImagingSelection-SourceImageForSegmentation

Page standards status: Informative

Raw xml | Download


<ImagingSelection xmlns="http://hl7.org/fhir">
  <id value="measurement-report-source-image-for-segmentation"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/source-image-for-segmentation"/>
  </meta>
  <language value="en"/>
  <text>
    <status value="generated"/>
    <div xml:lang="en" xmlns="http://www.w3.org/1999/xhtml" lang="en"><pre>
{
&quot;00081199&quot;: { &quot;vr&quot;: &quot;SQ&quot;, &quot;Value&quot;: [ {
      &quot;00081150&quot;: { &quot;vr&quot;: &quot;UI&quot;, &quot;Value&quot;: [ &quot;1.2.840.10008.5.1.4.1.1.2&quot; ] },
      &quot;00081155&quot;: { &quot;vr&quot;: &quot;UI&quot;, &quot;Value&quot;: [ &quot;1.2.840.113747.20080222.83341314456631405221767081790268995.1.1&quot; ] },
    } ] },
&quot;0040A010&quot;: { &quot;vr&quot;: &quot;CS&quot;, &quot;Value&quot;: [ &quot;CONTAINS&quot; ] },
&quot;0040A040&quot;: { &quot;vr&quot;: &quot;CS&quot;, &quot;Value&quot;: [ &quot;IMAGE&quot; ] },
&quot;0040A043&quot;: { &quot;vr&quot;: &quot;SQ&quot;, &quot;Value&quot;: [ {
      &quot;00080100&quot;: { &quot;vr&quot;: &quot;SH&quot;, &quot;Value&quot;: [ &quot;121233&quot; ] },
      &quot;00080102&quot;: { &quot;vr&quot;: &quot;SH&quot;, &quot;Value&quot;: [ &quot;DCM&quot; ] },
      &quot;00080104&quot;: { &quot;vr&quot;: &quot;LO&quot;, &quot;Value&quot;: [ &quot;Source Image For Segmentation&quot; ] }
    } ] }
},
{
&quot;0040A010&quot;: { &quot;vr&quot;: &quot;CS&quot;, &quot;Value&quot;: [ &quot;CONTAINS&quot; ] },
&quot;0040A040&quot;: { &quot;vr&quot;: &quot;CS&quot;, &quot;Value&quot;: [ &quot;UIDREF&quot; ] },
&quot;0040A043&quot;: { &quot;vr&quot;: &quot;SQ&quot;, &quot;Value&quot;: [ {
      &quot;00080100&quot;: { &quot;vr&quot;: &quot;SH&quot;, &quot;Value&quot;: [ &quot;121232&quot; ] },
      &quot;00080102&quot;: { &quot;vr&quot;: &quot;SH&quot;, &quot;Value&quot;: [ &quot;DCM&quot; ] },
      &quot;00080104&quot;: { &quot;vr&quot;: &quot;LO&quot;, &quot;Value&quot;: [ &quot;Source series for segmentation&quot; ] }
    } ] },
&quot;0040A124&quot;: { &quot;vr&quot;: &quot;UI&quot;, &quot;Value&quot;: [ &quot;1.2.840.113747.20080222.83341314456631405221767081790268995.1&quot; ] }
}
  </pre></div>
  </text>
  <status value="available"/>
  <subject>🔗 
    <reference value="Patient/measurement-report-patient"/>
  </subject>
  <code>
    <coding>
      <system value="http://dicom.nema.org/resources/ontology/DCM"/>
      <code value="121233"/>
      <display value="Source image for segmentation"/>
    </coding>
  </code>
  <derivedFrom>🔗 
    <reference value="ImagingStudy/measurement-report-imaging-study"/>
  </derivedFrom>
  <seriesUid
             value="1.2.840.113747.20080222.83341314456631405221767081790268995.1"/>
  <focus>🔗 
    <reference
               value="ImagingSelection/measurement-report-source-image-for-segmentation"/>
  </focus>
  <instance>
    <uid
         value="1.2.840.113747.20080222.83341314456631405221767081790268995.1.1"/>
    <sopClass>
      <system
              value="https://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5"/>
      <code value="1.2.840.10008.5.1.4.1.1.2"/>
      <display value="CT Image Storage"/>
    </sopClass>
  </instance>
</ImagingSelection>