DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
<ImagingSelection xmlns="http://hl7.org/fhir">
<id value="measurement-report-source-image-for-segmentation"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/source-image-for-segmentation"/>
</meta>
<language value="en"/>
<text>
<status value="generated"/>
<div xml:lang="en" xmlns="http://www.w3.org/1999/xhtml" lang="en"><pre>
{
"00081199": { "vr": "SQ", "Value": [ {
"00081150": { "vr": "UI", "Value": [ "1.2.840.10008.5.1.4.1.1.2" ] },
"00081155": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83341314456631405221767081790268995.1.1" ] },
} ] },
"0040A010": { "vr": "CS", "Value": [ "CONTAINS" ] },
"0040A040": { "vr": "CS", "Value": [ "IMAGE" ] },
"0040A043": { "vr": "SQ", "Value": [ {
"00080100": { "vr": "SH", "Value": [ "121233" ] },
"00080102": { "vr": "SH", "Value": [ "DCM" ] },
"00080104": { "vr": "LO", "Value": [ "Source Image For Segmentation" ] }
} ] }
},
{
"0040A010": { "vr": "CS", "Value": [ "CONTAINS" ] },
"0040A040": { "vr": "CS", "Value": [ "UIDREF" ] },
"0040A043": { "vr": "SQ", "Value": [ {
"00080100": { "vr": "SH", "Value": [ "121232" ] },
"00080102": { "vr": "SH", "Value": [ "DCM" ] },
"00080104": { "vr": "LO", "Value": [ "Source series for segmentation" ] }
} ] },
"0040A124": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83341314456631405221767081790268995.1" ] }
}
</pre></div>
</text>
<status value="available"/>
<subject>🔗
<reference value="Patient/measurement-report-patient"/>
</subject>
<code>
<coding>
<system value="http://dicom.nema.org/resources/ontology/DCM"/>
<code value="121233"/>
<display value="Source image for segmentation"/>
</coding>
</code>
<derivedFrom>🔗
<reference value="ImagingStudy/measurement-report-imaging-study"/>
</derivedFrom>
<seriesUid
value="1.2.840.113747.20080222.83341314456631405221767081790268995.1"/>
<focus>🔗
<reference
value="ImagingSelection/measurement-report-source-image-for-segmentation"/>
</focus>
<instance>
<uid
value="1.2.840.113747.20080222.83341314456631405221767081790268995.1.1"/>
<sopClass>
<system
value="https://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5"/>
<code value="1.2.840.10008.5.1.4.1.1.2"/>
<display value="CT Image Storage"/>
</sopClass>
</instance>
</ImagingSelection>