DICOM SR to FHIR Resource Mapping IG
0.1.0 - ci-build International flag

DICOM SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: ConceptMap - DICOM SR Measurement Report to FHIR Mapping - XML Representation

Draft as of 2024-04-02

Raw xml | Download



<ConceptMap xmlns="http://hl7.org/fhir">
  <id value="dicom-sr-measurement-report-to-fhir"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p>Mapping from DICOM-SR-Measurement-Report to <a href="http://hl7.org/fhir/R5/bundle.html">Bundle</a></p><p>DRAFT (not intended for production usage). Published on 2024-04-02 14:10:08+0000 by HL7 International / Imaging Integration (<a href="http://www.hl7.org/Special/committees/imagemgt/index.cfm">http://www.hl7.org/Special/com...</a>, HL7 International / Imaging Integration: <a href="http://www.hl7.org/Special/committees/imagemgt/index.cfm">http://www.hl7.org/Special/com...</a>, Jonathan Whitby: <a href="mailto:jonathan.whitby@mi.medical.canon">jonathan.whitby@mi.medical.canon</a>, <a href="http://www.hl7.org/Special/committees/imagemgt/index.cfm">http://www.hl7.org/Special/com...</a>, Christopher Lindop: <a href="mailto:Christopher.Lindop@ge.com">Christopher.Lindop@ge.com</a>, <a href="http://www.hl7.org/Special/committees/imagemgt/index.cfm">http://www.hl7.org/Special/com...</a>). </p><div><p>Mapping between DICOM SR Measurement Report and FHIR Resources</p>
</div><br/><p><b>Group 1</b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Patient (Patient IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Patient[1]</td><td>The DICOM SR Patient IE is mapped to a FHIR Patient resource</td></tr></table><hr/><p><b>Group 2</b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>ImagingStudy[1]</td><td>The DICOM SR Study IE is mapped to a FHIR ImagingStudy resource</td></tr><tr><td>DICOM.Study (Study IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#related-to" title="related-to">is related to</a></td><td>ServiceRequest[1]</td><td>The DICOM SR Study IE is mapped to a FHIR ServiceRequest resource</td></tr></table><hr/><p><b>Group 3</b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Equipment (Equipment IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent" title="equivalent">is equivalent to</a></td><td>Device[1]</td><td>The DICOM SR Equipment IE may result in the creation of a new Device resource</td></tr></table><hr/><p><b>Group 4</b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class="grid"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>DICOM.Document (Document IE)</td><td><a href="http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#source-is-narrower-than-target" title="source-is-narrower-than-target">is narrower than</a></td><td>Observation[1]</td><td>Processing of the Document IE will result in the creation one or more new Observation resources</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="ii"/>
  </extension>
  <url
       value="http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-sr-measurement-report-to-fhir"/>
  <version value="0.1.0"/>
  <name value="DICOMSRMeasurementReportToFHIRMapping"/>
  <title value="ConceptMap - DICOM SR Measurement Report to FHIR Mapping"/>
  <status value="draft"/>
  <experimental value="true"/>
  <date value="2024-04-02T14:10:08+00:00"/>
  <publisher value="HL7 International / Imaging Integration"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value
             value="http://www.hl7.org/Special/committees/imagemgt/index.cfm"/>
    </telecom>
  </contact>
  <contact>
    <name value="HL7 International / Imaging Integration"/>
    <telecom>
      <system value="url"/>
      <value
             value="http://www.hl7.org/Special/committees/imagemgt/index.cfm"/>
    </telecom>
  </contact>
  <contact>
    <name value="Jonathan Whitby"/>
    <telecom>
      <system value="email"/>
      <value value="jonathan.whitby@mi.medical.canon"/>
    </telecom>
    <telecom>
      <system value="url"/>
      <value
             value="http://www.hl7.org/Special/committees/imagemgt/index.cfm"/>
    </telecom>
  </contact>
  <contact>
    <name value="Christopher Lindop"/>
    <telecom>
      <system value="email"/>
      <value value="Christopher.Lindop@ge.com"/>
    </telecom>
    <telecom>
      <system value="url"/>
      <value
             value="http://www.hl7.org/Special/committees/imagemgt/index.cfm"/>
    </telecom>
  </contact>
  <description
               value="Mapping between DICOM SR Measurement Report and FHIR Resources"/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
    </coding>
  </jurisdiction>
  <property>
    <code value="references"/>
    <type value="string"/>
  </property>
  <property>
    <code value="imaging-measurement-group-map"/>
    <type value="string"/>
  </property>
  <sourceScopeUri value="DICOM-SR-Measurement-Report"/>
  <targetScopeUri value="Bundle"/>
  <group>
    <element>
      <code value="DICOM.Patient"/>
      <display value="Patient IE"/>
      <target>
        <code value="Patient[1]"/>
        <display value="Patient[1]"/>
        <relationship value="equivalent"/>
        <comment
                 value="The DICOM SR Patient IE is mapped to a FHIR Patient resource"/>
      </target>
    </element>
  </group>
  <group>
    <element>
      <code value="DICOM.Study"/>
      <display value="Study IE"/>
      <target>
        <code value="ImagingStudy[1]"/>
        <display value="ImagingStudy[1]"/>
        <relationship value="equivalent"/>
        <comment
                 value="The DICOM SR Study IE is mapped to a FHIR ImagingStudy resource"/>
      </target>
    </element>
    <element>
      <code value="DICOM.Study"/>
      <display value="Study IE"/>
      <target>
        <code value="ServiceRequest[1]"/>
        <display value="ServiceRequest[1]"/>
        <relationship value="related-to"/>
        <comment
                 value="The DICOM SR Study IE is mapped to a FHIR ServiceRequest resource"/>
      </target>
    </element>
  </group>
  <group>
    <element>
      <code value="DICOM.Equipment"/>
      <display value="Equipment IE"/>
      <target>
        <code value="Device[1]"/>
        <display value="Device[1]"/>
        <relationship value="equivalent"/>
        <comment
                 value="The DICOM SR Equipment IE may result in the creation of a new Device resource"/>
      </target>
    </element>
  </group>
  <group>
    <element>
      <code value="DICOM.Document"/>
      <display value="Document IE"/>
      <target>
        <code value="Observation[1]"/>
        <display value="Observation[1]"/>
        <relationship value="source-is-narrower-than-target"/>
        <comment
                 value="Processing of the Document IE will result in the creation one or more new Observation resources"/>
        <property>
          <code value="imaging-measurement-group-map"/>
          <valueString value="dicom-imaging-measurement-group-to-fhir"/>
        </property>
        <property>
          <code value="references"/>
          <valueString value="Observation.subject.reference=Patient[1].id"/>
        </property>
        <property>
          <code value="references"/>
          <valueString
                       value="Observation.partOf.reference=ImagingStudy[1].id"/>
        </property>
        <property>
          <code value="references"/>
          <valueString
                       value="Observation.basedOn.reference=ServiceRequest[1].id"/>
        </property>
        <property>
          <code value="references"/>
          <valueString value="Observation.device.reference=Device[1]"/>
        </property>
      </target>
    </element>
  </group>