Data Exchange For Quality Measures Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 5.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/davinci-deqm/ and changes regularly. See the Directory of published versions

: Bulk Submit Data - JSON Representation

Page standards status: Trial-use Maturity Level: 0

Raw json | Download

{
  "resourceType" : "OperationDefinition",
  "id" : "bulk-submit-data",
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p>URL: [base]/Measure/$bulk-submit-data</p><p>URL: [base]/Measure/[id]/$bulk-submit-data</p><p>Parameters</p><table class=\"grid\"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>measureReport</td><td>1..*</td><td><a href=\"http://hl7.org/fhir/R4/measurereport.html\">MeasureReport</a></td><td/><td><div><p>The measure report that is being submitted</p>\n</div></td></tr><tr><td>IN</td><td>exportType</td><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#code\">code</a></td><td/><td><div><p>(Optional) String of <code>static</code> or <code>dynamic</code>. Defaults to <code>dynamic</code> if omitted.</p>\n<p>If the value is <code>dynamic</code>, the Data Consumer will issue a POST request to the <code>exportUrl</code> to obtain a dataset from the Data Provider.</p>\n<p>If the value is <code>static</code>, the Data Consumer will issue a GET request to the <code>exportUrl</code> to retrieve a Bulk Data manifest file with the location of the Bulk Data files.</p>\n</div></td></tr><tr><td>IN</td><td>exportUrl</td><td>1..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#url\">url</a></td><td/><td><div><p>The absolute URL of the bulk export endpoint of a Data Provider (if the <code>exportType</code> parameter is <code>dynamic</code>) OR the location of a FHIR Bulk Data Export manifest file (if the <code>exportType</code> parameter is <code>static</code>)</p>\n</div></td></tr><tr><td>IN</td><td>_type</td><td>0..*</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#string\">string</a></td><td/><td><div><p>(Optional) Restrict the data exported to only be specific FHIR resource types. See <a href=\"https://hl7.org/fhir/uv/bulkdata/export/index.html#query-parameters\">the bulk data $export spec</a> for more information on '_type'</p>\n</div></td></tr><tr><td>IN</td><td>useTypeFilters</td><td>0..1</td><td><a href=\"http://hl7.org/fhir/R4/datatypes.html#boolean\">boolean</a></td><td/><td><div><p>(Optional) If enabled, data exported by the 'exportUrl' system will be filtered according to the data requirements of the Measure. Requires support of the _typeFilter experimental parameter in the export server. See <a href=\"https://hl7.org/fhir/uv/bulkdata/export/index.html#example-request-with-_typefilter\">the bulk data $export spec</a> for more information on '_typeFilter'</p>\n</div></td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger" : 0
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode" : "trial-use"
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "cqi"
    }
  ],
  "url" : "http://hl7.org/fhir/us/davinci-deqm/OperationDefinition/bulk-submit-data",
  "version" : "5.0.0",
  "name" : "BulkSubmitData",
  "title" : "Bulk Submit Data",
  "status" : "active",
  "kind" : "operation",
  "date" : "2022-11-09T10:53:32-05:00",
  "publisher" : "HL7 International / Clinical Quality Information",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/cqi"
        }
      ]
    }
  ],
  "description" : "The bulk-submit-data operation sends a bulk import request based on the data requirements of a FHIR Measure. This operation is modeled off the existing draft of the [Bulk Data Import Ping and Pull Approach](https://github.com/smart-on-fhir/bulk-import/blob/master/import-pnp.md).",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "US"
        }
      ]
    }
  ],
  "code" : "bulk-submit-data",
  "resource" : [
    "Measure"
  ],
  "system" : false,
  "type" : true,
  "instance" : true,
  "parameter" : [
    {
      "name" : "measureReport",
      "use" : "in",
      "min" : 1,
      "max" : "*",
      "documentation" : "The measure report that is being submitted",
      "type" : "MeasureReport"
    },
    {
      "name" : "exportType",
      "use" : "in",
      "min" : 0,
      "max" : "1",
      "documentation" : "(Optional) String of `static` or `dynamic`. Defaults to `dynamic` if omitted.\n\nIf the value is `dynamic`, the Data Consumer will issue a POST request to the `exportUrl` to obtain a dataset from the Data Provider.\n\nIf the value is `static`, the Data Consumer will issue a GET request to the `exportUrl` to retrieve a Bulk Data manifest file with the location of the Bulk Data files.",
      "type" : "code"
    },
    {
      "name" : "exportUrl",
      "use" : "in",
      "min" : 1,
      "max" : "1",
      "documentation" : "The absolute URL of the bulk export endpoint of a Data Provider (if the `exportType` parameter is `dynamic`) OR the location of a FHIR Bulk Data Export manifest file (if the `exportType` parameter is `static`)",
      "type" : "url"
    },
    {
      "name" : "_type",
      "use" : "in",
      "min" : 0,
      "max" : "*",
      "documentation" : "(Optional) Restrict the data exported to only be specific FHIR resource types. See [the bulk data $export spec](https://hl7.org/fhir/uv/bulkdata/export/index.html#query-parameters) for more information on '_type'",
      "type" : "string"
    },
    {
      "name" : "useTypeFilters",
      "use" : "in",
      "min" : 0,
      "max" : "1",
      "documentation" : "(Optional) If enabled, data exported by the 'exportUrl' system will be filtered according to the data requirements of the Measure. Requires support of the _typeFilter experimental parameter in the export server. See [the bulk data $export spec](https://hl7.org/fhir/uv/bulkdata/export/index.html#example-request-with-_typefilter) for more information on '_typeFilter'",