Data Exchange For Quality Measures Implementation Guide
5.0.0 - STU5 United States of America flag

Data Exchange For Quality Measures Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 5.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/davinci-deqm/ and changes regularly. See the Directory of published versions

CapabilityStatement: Consumer Client CapabilityStatement

Official URL: http://hl7.org/fhir/us/davinci-deqm/CapabilityStatement/consumer-client Version: 5.0.0
Active as of 2020-07-05 Computable Name: ConsumerClientCapabilityStatement
Other Identifiers: OID:2.16.840.1.113883.4.642.40.2.13.1

This profile defines the expected capabilities of a Da Vinci DEQM Consumer Client when conforming to the Da Vinci DEQM Implementation Guide. Consumers include systems that are primary consumers of patient healthcare information and systems that consume data from Producers. This CapabilityStatement resource includes the complete list of the recommended Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Consumer Client could support. Clients have the option of choosing from this list based on their local use cases and other contextual requirements.

Raw OpenAPI-Swagger Definition file | Download

Generated Narrative: CapabilityStatement consumer-client

Consumer Client CapabilityStatement

  • Implementation Guide Version: 5.0.0
  • FHIR Version: 4.0.1
  • Supported Formats: xml, json
  • Supported Patch Formats: application/json-patch+json
  • Published on: 2020-07-05
  • Published by: HL7 International / Clinical Quality Information

Note to Implementers: FHIR Capabilities

Any FHIR capability may be 'allowed' by the system unless explicitly marked as 'SHALL NOT'. A few items are marked as MAY in the Implementation Guide to highlight their potential relevance to the use case.

SHALL Support the Following Implementation Guides

FHIR RESTful Capabilities

Mode: client

Da Vinci DEQM Consumer Client SHALL support the Collect Data transaction defined in the Framework Section of this Implementation Guide.

Security

For general security consideration refer to the Security and Privacy Considerations.

Summary of System-wide Interactions
  • MAY support the transactioninteraction.
  • MAY support the batchinteraction.
  • MAY support the search-systeminteraction.
  • MAY support the history-systeminteraction.

Capabilities by Resource/Profile

Summary

The summary table lists the resources that are part of this configuration, and for each resource it lists:

  • The relevant profiles (if any)
  • The interactions supported by each resource (Read, Search, Update, and Create, are always shown, while VRead, Patch, Delete, History on Instance, or History on Type are only present if at least one of the resources has support for them.
  • The required, recommended, and some optional search parameters (if any).
  • The linked resources enabled for _include
  • The other resources enabled for _revinclude
  • The operations on the resource (if any)
Resource TypeProfileRSUCSearches_include_revincludeOperations
MeasureSupported Profiles
  CRMI Shareable Measure
y$collect-data
MeasureReportSupported Profiles
  DEQM Data Exchange MeasureReport Profile
y

Resource Conformance: SHALL Measure

Core FHIR Resource
Measure
Reference Policy
Interaction summary
  • SHOULD support read.

Supported Profiles

CRMI Shareable Measure

Extended Operations
ConformanceOperationDocumentation
SHOULD$collect-data

Resource Conformance: SHALL MeasureReport

Core FHIR Resource
MeasureReport
Reference Policy
Interaction summary
  • SHOULD support read.

Documentation

The DaVinci DEQM Consumer Client SHOULD be capable of supporting the DEQM MeasureReport Profile and all the DEQM, CQFM and QI Core Profiles they reference.