Clinical Practice Guidelines, published by HL7 International / Clinical Decision Support. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cqf-recommendations/ and changes regularly. See the Directory of published versions
| Official URL: http://hl7.org/fhir/uv/cpg/ValueSet/cpg-compliance-result-vs | Version: 3.0.0-ballot | ||||
| Active as of 2026-11-10 | Computable Name: CPGComplianceResultVS | ||||
| Other Identifiers: OID:2.16.840.1.113883.4.642.40.48.48.11 | |||||
The result of evaluating a compliance metric scoped to a recommendation. This is the default result value set for a compliance metric scoped to a CPGRecommendation. Includes the operational states shared with the CPG Adherence Result value set.
References
This value set is not used here; it may be used elsewhere (e.g. specifications and/or implementations that use this content)
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs version 📦3.0.0-ballot| Code | Display | Definition |
| compliant | Compliant | The care delivered conforms to the scoped recommendation: the proposed activity was fulfilled by a corresponding request and/or event as specified, including any timing constraints, or, for a recommendation against an activity, the activity was not performed. |
| compliant-with-prior-non-compliance | Compliant with Prior Non-Compliance | Compliant, with at least one prior evaluation of the same metric for the same patient non-compliant within the metric's declared lookback. |
| non-compliant | Non-Compliant | The care delivered does not conform to the scoped recommendation and no accepted exemption applies: the proposed activity was not fulfilled, was fulfilled outside the specified time window, or, for a recommendation against an activity, the activity was performed. |
| at-risk-for-non-compliance | At Risk for Non-Compliance | Not determined to be non-compliant, but the metric's declared predictive criterion indicates that non-compliance is likely within a declared horizon without intervention. |
| pending | Pending | The scoped element applies and its fulfillment window remains open; the expectation has not yet been met, has not yet failed, and no result is yet forced. A pending result is not final. |
| on-hold | On Hold | An authorized, currently effective temporary suspension of the scoped element's expectations under the metric's policy, while the element still applies and is not exempted. Makes no claim of success or failure; the last established result is retained as history and the metric is re-evaluated on resumption. A workflow hold (for example a CPGHoldTask or an on-hold request) is evidence of suspension only where the metric's policy accepts it. |
| exempted | Exempted | The scoped recommendation or strategy applies to the patient, but an exemption accepted by the metric's policy (e.g., contraindication, clinical judgment, or a patient refusal where the policy accepts it) removes the expectation. An exemption accepted by one strategy does not by itself exempt the same component in another. |
| not-applicable | Not Applicable | The scoped recommendation or strategy does not apply to the patient (e.g., its applicability criteria are not met), so no compliance or adherence expectation exists. A component that does not apply does not by itself make its parent not applicable. |
| not-yet-evaluated | Not Yet Evaluated | An explicit assertion that the metric, though defined for the patient's case, has not yet been evaluated. The absence of a result does not imply this code. |
| unknown | Unknown | The metric was evaluated, but the result cannot be determined from the available data. An engine failure is reported through MeasureReport.status, not with this code; missing evidence for a refinement alone does not erase an established broader result. |
Expansion performed internally based on codesystem CPG Metric Result Code System v3.0.0-ballot (CodeSystem)
This value set contains 10 concepts
| System | Code | Display (en) | Definition | JSON | XML |
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | compliant | Compliant | The care delivered conforms to the scoped recommendation: the proposed activity was fulfilled by a corresponding request and/or event as specified, including any timing constraints, or, for a recommendation against an activity, the activity was not performed. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | compliant-with-prior-non-compliance | Compliant with Prior Non-Compliance | Compliant, with at least one prior evaluation of the same metric for the same patient non-compliant within the metric's declared lookback. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | non-compliant | Non-Compliant | The care delivered does not conform to the scoped recommendation and no accepted exemption applies: the proposed activity was not fulfilled, was fulfilled outside the specified time window, or, for a recommendation against an activity, the activity was performed. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | at-risk-for-non-compliance | At Risk for Non-Compliance | Not determined to be non-compliant, but the metric's declared predictive criterion indicates that non-compliance is likely within a declared horizon without intervention. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | pending | Pending | The scoped element applies and its fulfillment window remains open; the expectation has not yet been met, has not yet failed, and no result is yet forced. A pending result is not final. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | on-hold | On Hold | An authorized, currently effective temporary suspension of the scoped element's expectations under the metric's policy, while the element still applies and is not exempted. Makes no claim of success or failure; the last established result is retained as history and the metric is re-evaluated on resumption. A workflow hold (for example a CPGHoldTask or an on-hold request) is evidence of suspension only where the metric's policy accepts it. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | exempted | Exempted | The scoped recommendation or strategy applies to the patient, but an exemption accepted by the metric's policy (e.g., contraindication, clinical judgment, or a patient refusal where the policy accepts it) removes the expectation. An exemption accepted by one strategy does not by itself exempt the same component in another. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | not-applicable | Not Applicable | The scoped recommendation or strategy does not apply to the patient (e.g., its applicability criteria are not met), so no compliance or adherence expectation exists. A component that does not apply does not by itself make its parent not applicable. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | not-yet-evaluated | Not Yet Evaluated | An explicit assertion that the metric, though defined for the patient's case, has not yet been evaluated. The absence of a result does not imply this code. | ||
http://hl7.org/fhir/uv/cpg/CodeSystem/cpg-metric-result-cs | unknown | Unknown | The metric was evaluated, but the result cannot be determined from the available data. An engine failure is reported through MeasureReport.status, not with this code; missing evidence for a refinement alone does not erase an established broader result. |