Vital Signs with Qualifying Elements
2.0.0 - ci-build International flag

Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This is not an authorized publication; it is the continuous build for version 2.0.0). This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions

: Respiratory Rate Measurement Device value set - XML Representation

Draft as of 2023-07-18

Raw xml | Download



<ValueSet xmlns="http://hl7.org/fhir">
  <id value="respiratoryRateMeasDeviceVS"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://snomed.info/id/717730001">717730001</a></td><td>Impedance pneumography recording/analysis system (physical object)</td></tr><tr><td><a href="http://snomed.info/id/334990001">334990001</a></td><td>Peak flow meter (physical object)</td></tr><tr><td><a href="http://snomed.info/id/462575001">462575001</a></td><td>Patient monitoring system module, electrocardiographic/respiratory (physical object)</td></tr><tr><td><a href="http://snomed.info/id/463005003">463005003</a></td><td>Patient monitoring system module, respiratory (physical object)</td></tr></table></li><li>Include these codes as defined in <a href="CodeSystem-SolorTemporaryCodeSystem.html"><code>http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-23921000205109">23921000205109</a></td><td>Respiration strain gauge (physical object)</td><td>A device wrapped around a subject chest that measures the number of times a subject's chest expands with each inhalation.  This counts the breaths per minute.</td></tr><tr><td><a href="CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-23861000205107">23861000205107</a></td><td>Capnograph sensor device (physical object)</td><td>A device that captures expelled air, either via nasal prongs or CPAP and is used to measure the number of breaths taken per minute.</td></tr></table></li></ul></div>
  </text>
  <url
       value="http://hl7.org/fhir/us/vitals/ValueSet/respiratoryRateMeasDeviceVS"/>
  <version value="2.0.0"/>
  <name value="RespiratoryRateMeasurementDevicevalueset"/>
  <title value="Respiratory Rate Measurement Device value set"/>
  <status value="draft"/>
  <date value="2023-07-18T14:07:06+00:00"/>
  <publisher
             value="HL7 International - Clinical Information Modeling Initiative"/>
  <contact>
    <name
          value="HL7 International - Clinical Information Modeling Initiative"/>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org/Special/committees/cimi"/>
    </telecom>
  </contact>
  <contact>
    <name value="Logica"/>
    <telecom>
      <system value="url"/>
      <value value="https://www.logicahealth.org/"/>
    </telecom>
  </contact>
  <description
               value="SELECT SNOMED CT code system values that describe instruments used to measure respiratory rates."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <copyright
             value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
  <compose>
    <include>
      <system value="http://snomed.info/sct"/>
      <concept>
        <code value="717730001"/>
        <display
                 value="Impedance pneumography recording/analysis system (physical object)"/>
      </concept>
      <concept>
        <code value="334990001"/>
        <display value="Peak flow meter (physical object)"/>
      </concept>
      <concept>
        <code value="462575001"/>
        <display
                 value="Patient monitoring system module, electrocardiographic/respiratory (physical object)"/>
      </concept>
      <concept>
        <code value="463005003"/>
        <display
                 value="Patient monitoring system module, respiratory (physical object)"/>
      </concept>
    </include>
    <include>
      <system
              value="http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem"/>
      <concept>
        <code value="23921000205109"/>
        <display value="Respiration strain gauge (physical object)"/>
      </concept>
      <concept>
        <code value="23861000205107"/>
        <display value="Capnograph sensor device (physical object)"/>
      </concept>
    </include>
  </compose>
</ValueSet>